ASTM E832-1981(2003) Standard Specification for Laboratory Filter Papers《实验室滤纸》.pdf
《ASTM E832-1981(2003) Standard Specification for Laboratory Filter Papers《实验室滤纸》.pdf》由会员分享,可在线阅读,更多相关《ASTM E832-1981(2003) Standard Specification for Laboratory Filter Papers《实验室滤纸》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 832 81 (Reapproved 2003)Standard Specification forLaboratory Filter Papers1This standard is issued under the fixed designation E 832; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A numbe
2、r in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification covers two types of filter paper for us
3、ein chemical analysis and provides procedures for the completeevaluation of the filter papers.2. Referenced Documents2.1 ASTM Standards:D 774 Test Method for Bursting Strength of Paper22.2 TAPPI Standards:3T413 Ash in PaperT429 Alpha-Cellulose in PaperT509 Hydrogen Ion Concentration (pH) of Paper Ex
4、tractsCold Extraction Method3. Types and Classes3.1 The types and classes of filter paper are as follows:3.1.1 Type ITo be used for qualitative analysis (low ashcontent):3.1.1.1 Class AA, for very coarse and gelatinous precipi-tates, very fast flow rate.3.1.1.2 Class A, for coarse and gelatinous pre
5、cipitates, fastflow rate.3.1.1.3 Class B, for medium-size precipitates, medium flowrate.3.1.1.4 Class C, for fine precipitates, slow flow rate.3.1.1.5 Class D, hardened to facilitate scraping, for fineprecipitates, slow flow rate.3.1.2 Type IIto be used for quantitative analysis (ashlesspapers):3.1.
6、2.1 Class E, for coarse and gelatinous precipitates, fastflow rate.3.1.2.2 Class F, for medium-size precipitates, medium flowrate.3.1.2.3 Class G, for fine precipitates, slow flow rate.4. Manufacture4.1 The papers shall be made from such materials and bysuch methods as to ensure compliance with the
7、requirements ofSection 10, and shall be clean and free of imperfections thatwould affect their performance.4.2 The papers shall be converted into circles, sheets, or anyrequired sizes.5. General Requirements General Requirements5.1 All classes of filter paper shall comply with the require-ments give
8、n in Table 1 and Table 2 and Section 11.5.2 The ash content of the Type II circles shall not exceed0.01 %.5.3 Class D filter papers shall have a surface hard enough topermit scraping collected precipitates off the sheet.6. Sampling6.1 If testing is required, the sample of each class shall berepresen
9、tative of the shipment, and specimens shall be taken atrandom from at least 3 % of the total packages.7. Retests7.1 If the results of the tests indicate noncompliance withthe requirements of Table 1 and Table 2, or other factorsdescribed within this specification, take another representativesample o
10、f the shipment, selecting the specimens from differentpackages than those from which the first sample was taken.7.2 Then test the second sample for compliance with thisspecification.7.3 If the results of the retests indicate noncompliance withthis specification, immediately consult the manufacturer
11、forassistance in rectifying the problem.8. Packaging and Marking8.1 Flat circles of filter paper shall be packaged in units of100 circles of the same diameter. Prefolded or fluted circlesshall be packaged according to trade custom.1This specification is under the jurisdiction of ASTM CommmitteeE41 o
12、nLaboratory Apparatus and is the direct responsibility of Subcommittee E41.01 onApparatus.Current edition approved Oct. 1, 2003. Published October 2003. Originallypublished as D 1100 50 T. Last previous edition D 1100 52 (1971). Redesignatedas E832 in June 1981.2Annual Book of ASTM Standards, Vol 15
13、.09.3Available from Technical Association of the Pulp and Paper Industry, Technol-ogy Park/Atlanta, P.O. Box 105113, Atlanta, GA 30348.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.8.2 Each unit or package shall be marked with the
14、manu-facturers name, size of circles, or catalog and lot number.9. Test Methods9.1 The most important tests to be performed are:9.1.1 pH ValueDetermine in accordance with TAPPIMethod T 509.9.1.2 Alpha-CelluloseDetermine in accordance withTAPPI Method T 429. This test may or may not be used for lotto
15、 lot determination.9.1.3 Ash ContentDetermine in accordance with Section10.1 or TAPPI Method T 413, applicable for Type II papers.9.1.4 Retention of precipitates, simple method to determineretention ability of filter paper as determined in accordancewith 10.2.9.1.5 Water Flow RateDetermine the flow
16、rates of filterpaper in accordance with 10.3 or the Herzberg method (mea-surement of time for the filtration of 100 mL of prefiltereddistilled water with a filter surface of 10 cm2at a constantpressure of 50 mm water column).9.1.6 Wet Bursting StrengthDetermine in accordance with10.4.10. Test Method
17、s10.1 Ash Content:10.1.1 Apparatus:10.1.1.1 Crucibles, 20-mL platinum, with tightly fittingcovers. One for each sample.10.1.1.2 Heat SourceAn electric muffle furnace with anoperating temperature of approximately 925C is recom-mended, but a gas burner yielding a similar temperature issufficient.10.1.
18、1.3 Test specimens, having a mass of at least 6 g,representative of the sample obtained as prescribed in Section6, and cut in the shape of whole circles of the same diameter orsmall strips measured for area.10.1.2 Procedure:10.1.2.1 Heat the crucibles with their respective covers toapproximately 925
19、C. Cool in a desiccator and weigh to thenearest 0.1 mg. Add the specimen into crucible.10.1.2.2 Heat the covered crucible plus test specimen gradu-ally until smoking ceases, remove cover, then continue heatinguntil the maximum temperature of 925C is reached andmaintain for 2 h. Replace the cover and
20、 cool the coveredcrucible in a desiccator until temperature equilibrium with thesurrounding air is reached. Weigh the crucible and contents tothe nearest 0.1 mg. Ignition is considered to be complete whenthe weight of the covered crucible and ash does not change bymore than 0.2 mg after reheating at
21、 925C for 30 min.10.1.2.3 BlankCarry a tare crucible with cover through alloperations in exactly the same manner as the crucibles con-taining specimens, as a check on possible loss of mass of thecrucibles themselves.10.1.2.4 Test at least two specimens per sample.10.1.3 Calculation and ReportCalcula
22、te and report theash, corrected for the results of the blank test, to two significantfigures. Determine the weight percentage of the paper dried at105C.10.1.4 PrecisionDuplicate determinations shall agree asfollows:Ash, %Rounded toNearestReproducibility, %0.025 0.001 0.0030.025 to 0.01 0.005 0.010.1
23、 0.01 0.0210.2 Retention of Precipitates:10.2.1 Apparatus:10.2.1.1 Glass Funnels, 60, having stems about 6 in. long.10.2.2 Reagents:10.2.2.1 Alcohol (95 %)Ethanol or formula No. 30.10.2.2.2 Ammonium HydroxideAdd one part, by volume,of cp ammonium hydroxide (NH4OH) to one part by volumeof distilled w
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME83219812003STANDARDSPECIFICATIONFORLABORATORYFILTERPAPERS 实验室 滤纸 PDF

链接地址:http://www.mydoc123.com/p-533623.html