1、Designation: E814 11aE814 13 An American National StandardStandard Test Method forFire Tests of Penetration Firestop Systems1This standard is issued under the fixed designation E814; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.INTRODUCTIONCharacteristically fire s
3、preads from one building compartment to another by the collapse of abarrier, or by openings through which flames or hot gases may pass, or by transfer of sufficient heatto ignite combustibles beyond the barrier. Test Methods E119 describe the method to be used tomeasure the fire-resistive performanc
4、e of these barriers.However, various techniques of providing for the distribution of services within a structuresometimes require that openings be made in fire-resistive walls and floors to allow the passage of suchpenetrating items as cables, conduits, pipes, trays, and ducts through to the adjacen
5、t compartment.Fire-stop material is installed into these openings to resist the spread of fire.The performance of through-penetration firestops should be measured and specified according to acommon standard that describes the method of fire exposure and rating criteria.1. Scope1.1 This test method i
6、s applicable to firestop systems of various materials and construction. Firestop systems are intended foruse in openings in fire-resistive walls and floors that are evaluated in accordance with Test Methods E119.1.2 Tests conducted in conformance with this test method record firestop system performa
7、nce during the test exposure; but suchtests shall not be construed to determine suitability of the firestop system for use after test exposure.1.3 This test method also measures the resistance of firestop systems to an external force stimulated by a hose stream. However,this test method shall not be
8、 construed as determining the performance of the firestop system during actual fire conditions whensubjected to forces such as failure of cable support systems and falling debris.1.4 The intent of this test method is to develop data to assist others in determining the suitability of the firestops fo
9、r use wherefire resistance is required.1.5 This test method does not apply to membrane penetrations of a floor-ceiling assembly or roof-ceiling assembly that aretested as part of the assembly in accordance with Test Methods E119.1.6 This test method does not apply to membrane penetrations of load-be
10、aring walls.1.7 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information only and are not considered standard.1.8 This standard is used to measure and describe the response of mater
11、ials, products, or assemblies to heat and flame undercontrolled conditions, but does not by itself incorporate all factors required for fire-hazard or fire-risk assessment of materials,products, or assemblies under actual fire conditions.1.9 This standard does not purport to address all of the safet
12、y concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.1.10 The text of this standard references notes and footnotes which provide exp
13、lanatory material. These notes and footnotes(excluding those in tables and figures) shall not be considered requirements of the standard.1 This test method is under the jurisdiction of ASTM Committee E05 on Fire Standards and is the direct responsibility of Subcommittee E05.11 on Fire Resistance.Cur
14、rent edition approved April 1, 2011Nov. 1, 2013. Published April 2011November 2013. Originally approved in 1981. Last previous edition approved in 2011 asE814 11.E814 11a. DOI: 10.1520/E0814-11A.10.1520/E0814-13.This document is not an ASTM standard and is intended only to provide the user of an AST
15、M standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published
16、by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States12. Referenced Documents2.1 ASTM Standards:2E119 Test Methods for Fire Tests of Building Construction and MaterialsE176 Terminology of Fi
17、re StandardsE2226 Practice for Application of Hose Stream2.2 Other Documents:ANSI/UL 1479 Standard for Fire Tests of Through-Penetration Firestops3. Terminology3.1 Definitions:3.1.1 For definitions of terms used in this test method refer to Terminology E176.3.2 Definitions of Terms Specific to This
18、Standard:3.2.1 firestop system, na specific combination of penetrating item or items, the specific construction that is penetrated, and thematerials or devices, or both, that seal the opening provided to accommodate one or more items that penetrate into or through afire-resistance rated assembly.3.2
19、.1.1 DiscussionThe materials and devices used to seal the opening around penetrating items are sometimes referred to as “firestops.” Note thatit is not “firestops” that are tested by this standard, but rather “firestop systems.” Due to the complex interaction during a firebetween the penetrant, the
20、penetrated assembly, the materials and/or devices used to seal the penetration, and the specific size andshape of the opening, it is not possible to simply test the “firestop” to develop fire resistance data.3.2.2 membrane-penetration firestop system, na firestop system that seals the opening provid
21、ed to accommodate one or moreitems that penetrate the membrane on only one side of a fire-resistance rated assembly.3.2.2.1 DiscussionExamples of penetrating items include cables, conduits, ducts, pipes, and electrical boxes.3.2.3 test assemblythe wall or floor that is part of the firestop system be
22、ing tested into which the test specimen(s) is (are)mounted or installed.3.2.4 test specimenthe penetrating item or items and the materials or devices, or both, that seal the opening in the firestopsystem being tested.3.2.5 through-penetration firestop system, na firestop system that seals the openin
23、g around penetrating items that pass throughthe entire fire-resistance rated assembly.3.2.5.1 DiscussionExamples of penetrating items include cables, cable trays, conduits, ducts, and pipes.4. Summary of Test Method4.1 This method of testing through-penetration firestop systems exposes firestop syst
24、ems to a standard temperature-time fire,and to a subsequent application of a hose stream.4.2 Ratings are established on the basis of the period of resistance to the fire exposure, prior to the first development of throughopenings, flaming on the unexposed surface, limiting thermal transmission crite
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME8142013RED2167STANDARDTESTMETHODFORFIRETESTSOFPENETRATIONFIRESTOPSYSTEMS 贯穿 部阻火 系统 着火 试验 标准 方法 PDF

链接地址:http://www.mydoc123.com/p-533591.html