《ASTM E805-2012a(2017) 1250 Standard Practice for Identification of Instrumental Methods of Color or Color-Difference Measurement of Materials《材料的颜色或色差测量仪器法识别的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E805-2012a(2017) 1250 Standard Practice for Identification of Instrumental Methods of Color or Color-Difference Measurement of Materials《材料的颜色或色差测量仪器法识别的标准实施规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E805 12a (Reapproved 2017)Standard Practice forIdentification of Instrumental Methods of Color or Color-Difference Measurement of Materials1This standard is issued under the fixed designation E805; the number immediately following the designation indicates the year oforiginal adoption o
2、r, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the documentation of instrumentalmeasurement of color or
3、color difference for current commu-nication or for future reference. The practice is applicable toinstrumental measurements of materials where color is seen byreflected, transmitted or emitted light and any combinations ofone or more of these processes. The practice is recommendedfor documentation o
4、f methodology in interlaboratory color-measurement programs.1.2 Providing an adequate identification of an instrumentalmeasure of color or color-difference involves documenting themetadata necessary for archiving and future use of the mea-surement data collected. The metadata can be divided in fivep
5、arts:1.2.1 Nature and source of available samples and the formof specimens actually measured,1.2.2 Instrumental conditions of measurement, includinginstrument geometrical and spectral conditions ofmeasurement,1.2.3 Standards used,1.2.4 Data acquisition procedure, and1.2.5 Color scales employed.1.3 T
6、his standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of whoever uses this standard to consult andestablish appropriate safety and health practices and deter-mine the applicability of regulatory limitations prior to use.1.4 This
7、international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (T
8、BT) Committee.2. Referenced Documents2.1 ASTM Standards:2D156 Test Method for Saybolt Color of Petroleum Products(Saybolt Chromometer Method)D1209 Test Method for Color of Clear Liquids (Platinum-Cobalt Scale)D1500 Test Method for ASTM Color of Petroleum Products(ASTM Color Scale)D1535 Practice for
9、Specifying Color by the Munsell SystemD1544 Test Method for Color of Transparent Liquids (Gard-ner Color Scale)D2244 Practice for Calculation of Color Tolerances andColor Differences from Instrumentally Measured ColorCoordinatesD5386 Test Method for Color of Liquids Using TristimulusColorimetryD6166
10、 Test Method for Color of Pine Chemicals and Re-lated Products (Instrumental Determination of GardnerColor)E179 Guide for Selection of Geometric Conditions forMeasurement of Reflection and Transmission Propertiesof MaterialsE259 Practice for Preparation of Pressed Powder WhiteReflectance Factor Tran
11、sfer Standards for Hemisphericaland Bi-Directional GeometriesE284 Terminology of AppearanceE308 Practice for Computing the Colors of Objects by Usingthe CIE SystemE313 Practice for Calculating Yellowness and WhitenessIndices from Instrumentally Measured Color CoordinatesE991 Practice for Color Measu
12、rement of Fluorescent Speci-mens Using the One-Monochromator MethodE1164 Practice for Obtaining Spectrometric Data for Object-Color EvaluationE1247 Practice for Detecting Fluorescence in Object-ColorSpecimens by SpectrophotometryE1331 Test Method for Reflectance Factor and Color by1This practice is
13、under the jurisdiction of ASTM Committee E12 on Color andAppearance and is the direct responsibility of Subcommittee E12.04 on Color andAppearance Analysis.Current edition approved May 1, 2017. Published May 2017. Originallyapproved in 1981. Last previous edition approved in 2012 as E805 12a. DOI:10
14、.1520/E0805-12AR17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Har
15、bor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendat
16、ions issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1Spectrophotometry Using Hemispherical GeometryE1345 Practice for Reducing the Effect of Variability ofColor Measurement by Use of Multiple MeasurementsE1347 Test Method for Color and Color-Difference Mea-suremen
17、t by Tristimulus ColorimetryE1348 Test Method for Transmittance and Color by Spec-trophotometry Using Hemispherical GeometryE1349 Test Method for Reflectance Factor and Color bySpectrophotometry Using Bidirectional (45:0 or 0:45)GeometryE1708 Practice for Electronic Interchange of Color andAppearanc
18、e DataE1767 Practice for Specifying the Geometries of Observa-tion and Measurement to Characterize the Appearance ofMaterialsE2152 Practice for Computing the Colors of FluorescentObjects from Bispectral Photometric DataE2153 Practice for Obtaining Bispectral Photometric Datafor Evaluation of Fluores
19、cent ColorE2175 Practice for Specifying the Geometry of MultiangleSpectrophotometersE2194 Test Method for Multiangle Color Measurement ofMetal Flake Pigmented MaterialsE2729 Practice for Rectification of SpectrophotometricBandpass Differences2.2 Other Standard Documents:CIE Publication 51 A Method f
20、or Assessing the Quality ofDaylight Simulators for Colorimetry3DIN 6176 Farbmetrische, Bestimmung von Farbabstndebie Krperfarben nach der DIN99Formel43. Terminology3.1 Definitions of terms in Terminology E284 are applicableto this practice.3.2 Definitions of Terms Specific to This Standard:3.3 metad
21、ata, nstructered information that describes,explains, locates, and otherwise makes it easier to retrieve anduse an information resource (1).5NOTE 1In the case of color and color difference measurements, thedata about the instrument, the measurement procedure, the treatment ofthe specimen, identifica
22、tion of color scale and the calculations are to beincluded in the metadata.4. Significance and Use4.1 The options available in methods for the measurementof color or color-difference are many. These involve choices in:(1) specimens, (2) geometric and spectral properties ofinstruments, (3) calibratio
23、n bases for standards used, (4)procedure for sample handling including conditioning, (5)procedure for taking data, and (6) equations for convertinginstrumental data to final results. Once the measurements havebeen made, it is essential to document what has been done forthe purpose of interlaboratory
24、 comparisons, or for future use.Asample form is provided in Fig. 1 to record identifyinginformation applicable to any instrumental method of color orcolor-difference measurement.4.2 Refer to Guide E179, Practices E991, E1164, E1345,E1708, E1767, E2152, and E2194 and Test Methods D5386,D6166, E1247,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME8052012A20171250STANDARDPRACTICEFORIDENTIFICATIONOFINSTRUMENTALMETHODSOFCOLORORCOLORDIFFERENCEMEASUREMENTOFMATERIALS

链接地址:http://www.mydoc123.com/p-533566.html