ASTM E755-1994(2003) Standard Test Method for Dicumyl Peroxide Assay (Liquid Chromatography)《用液体色谱法作过氧化二异丙苯化验的测试方法》.pdf
《ASTM E755-1994(2003) Standard Test Method for Dicumyl Peroxide Assay (Liquid Chromatography)《用液体色谱法作过氧化二异丙苯化验的测试方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E755-1994(2003) Standard Test Method for Dicumyl Peroxide Assay (Liquid Chromatography)《用液体色谱法作过氧化二异丙苯化验的测试方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 755 94 (Reapproved 2003)Standard Test Method forDicumyl Peroxide, Assay (Liquid Chromatography)1This standard is issued under the fixed designation E 755; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of l
2、ast revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the assay of dicumyl peroxide2in commercially available refined grades of dicumyl peroxide.Tec
3、hnical grades can also be assayed, provided that impuritiesthat interfere chromatographically are absent (see Note 1).These materials nominally contain approximately 99 and 92 %of dicumyl peroxide, respectively.NOTE 1In the assay of technical grade dicumyl peroxide, errors arepossible if the product
4、 contains an impurity that elutes with the sameretention time as the internal standard. A chromatogram obtained underthe test conditions minus the internal standard will determine whether aninterference situation exists in the assay of a particular technical gradeproduct. If an impurity is noted, an
5、d its retention time is slightly differentfrom that of the internal standard, the interference can often be eliminatedby the use of a column known to have a high plate count.1.2 Review the current material safety data sheets (MSDS)for detailed information concerning toxicity, first aid proce-dures,
6、and safety precautions.1.3 The values stated in SI units are to be regarded as thestandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practi
7、ces and determine the applica-bility of regulatory limitations prior to use. Specific precau-tionary statements are given in Section 7.2. Referenced Documents2.1 ASTM Standards:3D 1193 Specification for Reagent WaterE 180 Practice for Determining the Precision of ASTMMethods for Analysis and Testing
8、 of Industrial ChemicalsE 682 Practice for Liquid Chromatography Terms and Re-lationshipsE 685 Practice for Testing Fixed-Wavelength PhotometricDetectors Used in Liquid ChromatographyE 300 Practice for Sampling Industrial Chemicals3. Summary of Test Method3.1 A solution of sample and internal standa
9、rd in methanolis chromatographed on a reversed-phase ODS column using85/15 methanol/water as the mobile phase and an ultraviolet(UV) detector at 254 nm. The percent of dicumyl peroxide inthe sample is determined by the internal standard technique,using the peak height ratios of standard and sample c
10、hromato-grams.4. Significance and Use4.1 This test method provides a means for determining thepercent of dicumyl peroxide in technical and refined grades ofthis material. This test method is specific for dicumyl peroxide.No interference is encountered from dimethylbenzyl alcohol,acetophenone, or oth
11、er minor impurities normally associatedwith commercial dicumyl peroxide.5. Apparatus5.1 Liquid Chromatograph, equipped with a 254-nm UVdetector, an injection valve, and an isocratic solvent deliverysystem capable of operating to a gage pressure of 3000 psi (21MPa). The detector should be equipped wi
12、th an attenuatorswitch to change the sensitivity range as required.5.2 Recorder, 0 to 10-mV range, or an electronic integratorwith printer-plotter, or both.5.3 Chromatographic Column, reversed-phase C-18, 250 by4.6-mm inside diameter, containing octadecyldimethylsilanechemically bonded to spherical,
13、 5-m microparticulate silica.4NOTE 2Commercial HPLC columns vary in physical dimensions,degree of substrate loading, and size and type of support material. Somemodification in the operating parameters may be required to achieveoptimum separation for these reasons.5.4 Guard Column, reversed-phase C-1
14、8, 12.5 by 4.0 mm,with an inline filter.41This test method is under the jurisdiction of ASTM Committee E15 onIndustrial and Specialty Chemicals and is the direct responsibility of SubcommitteeE15.02 on Product Standards.Current edition approved Dec. 15, 1994. Published February 1995. Originallypubli
15、shed as E 755 80. Last previous edition E 755 90.2Dicumyl Peroxide; peroxide, bis (1-methyl-1-phenyethyl) C18H22O2; CASRegistry No. 80-43-3.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volum
16、e information, refer to the standards Document Summary page onthe ASTM website.4The commercial guard and analytical columns found to be most satisfactory foruse with this test method are Zorbax Rx-18, Part Nos. 820764.914 and880967.9002, respectively, available from Mac Mod, 127 Commons Court, Chadd
17、sFord, PA 19317. This column was selected for its separation characteristics andlinear response of the dicumyl peroxide and internal standard.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.5 Precision Sample Injection Valve, with
18、a 10-L loop andfiller port.5.6 Syringe, 250-L capacity.5.7 Sample Filter, consisting of a syringe and 0.2-m filterassembly to remove microparticulate matter from the preparedsample solution.55.8 Glass Bottles, 4 oz, with polyethylene-lined screw caps.6. Reagents6.1 WaterPrepare ASTM Type II reagent
19、water in accor-dance with Specification D 1193, or distill deionized water.Filter through a 0.2-m, Nylon-66 filter, and store in a glasscontainer. Alternatively, commercial multicartridge systemsthat produce water meeting or exceeding the requirements ofType II can be used.6.2 Methanol, chromatograp
20、hic grade, distilled in glass.6.3 Methanol-Water Mobile Phase, 85:15Mix 8.5 vol-umes of methanol with 1.5 volumes of water.6.4 Di-n-Heptyl Phthalate, purified.66.5 Dicumyl Peroxide, RecrystallizedTransfer 25.0 g ofcommercial refined dicumyl peroxide into a 100-mL Erlenm-eyer flask. Add 8.0 mL of met
21、hanol, and gently warm thesolution in a water bath while swirling to effect completesolution. Cool to 0C in an ice bath. Transfer the contents to amedium-porosity sintered glass crucible and vacuum filter.Allow air to pass through the filter for 10 to 15 min to dry theperoxide. Repeat the crystalliz
22、ation twice using approximately1 mL of methanol solvent for every3gofperoxide. Place therecrystallized dicumyl peroxide in a tightly capped bottle, andstore in a refrigerator (see Section 7).7. Safety Precautions7.1 Small quantities of solid or molten dicumyl peroxidecan be handled safely at tempera
23、tures up to 55C. Dicumylperoxide should not be heated above 55C because the rate ofperoxide decomposition increases rapidly with increasing tem-peratures above this point.7.2 A recirculating water bath or a water bath that has beenpreheated to the desired temperature and removed from theheat source
24、should be used for warming vessels containingdicumyl peroxide. Electrically heated water baths should notbe used since they may cause localized hot spots. Other sourcesof heat considered unsafe for warming containers of dicumylperoxide include ovens, hot plates, open flames, and directsteam.7.3 Orga
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME75519942003STANDARDTESTMETHODFORDICUMYLPEROXIDEASSAYLIQUIDCHROMATOGRAPHY 液体 色谱 过氧化 异丙苯 化验 测试 方法

链接地址:http://www.mydoc123.com/p-533462.html