ASTM E754-1980(2006) Standard Test Method for Pullout Resistance of Ties and Anchors Embedded in Masonry Mortar Joints《埋入砖石灰缝中的拉杆和锚的拔拉阻力的标准测试方法》.pdf
《ASTM E754-1980(2006) Standard Test Method for Pullout Resistance of Ties and Anchors Embedded in Masonry Mortar Joints《埋入砖石灰缝中的拉杆和锚的拔拉阻力的标准测试方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E754-1980(2006) Standard Test Method for Pullout Resistance of Ties and Anchors Embedded in Masonry Mortar Joints《埋入砖石灰缝中的拉杆和锚的拔拉阻力的标准测试方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 754 80 (Reapproved 2006)Standard Test Method forPullout Resistance of Ties and Anchors Embedded inMasonry Mortar Joints1This standard is issued under the fixed designation E 754; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、 revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.INTRODUCTIONThe attachment of masonry walls to building exteriors has been based largely on experience and
3、professional judgment. Codes and standards requirements relating to the attachment of masonryveneer and nonload-bearing masonry walls generally specify the size and spacing of the fasteners tobe provided (ties or anchors) rather than the forces to be resisted. In addition, there are very limiteddata
4、 available on the structural performance of most types of fasteners currently used in masonryconstruction.This test method is recommended for determining conservative ultimate pullout values of masonryfasteners under conditions that approach those usually found in the upper courses of masonry wallco
5、nstruction, which experience little or practically no vertical load restraint. Its use is recommendeduntil more comprehensive methods are developed which can evaluate, economically, the capacity ofmasonry ties and anchors to resist pullout loads, giving due consideration to service parameters suchas
6、 expanse of surrounding wall area and in-plane dead loads.1. Scope1.1 This test method provides procedures for determiningthe ability of individual masonry ties and anchors to resistextraction from a masonry mortar joint.1.2 Two laboratory testing procedures are provided for usewith test specimens w
7、hich consist of a masonry tie or anchorembedded in mortar between twin stack-bonded masonry units.1.2.1 Procedure AFor use with small (brick-size) ma-sonry units.1.2.2 Procedure BFor use with large (block-size) ma-sonry units.1.3 This standard does not purport to address the safetyconcerns, if any,
8、associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealth practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C67 Test Methods for Sampling and Testing Brick andStruct
9、ural Clay TileC 109/C 109M Test Method for Compressive Strength ofHydraulic Cement Mortars(Using 2-in. or 50-mm CubeSpecimens)C 140 Test Methods for Sampling and Testing ConcreteMasonry Units and Related UnitsC 144 Specification for Aggregate for Masonry MortarC 270 Specification for Mortar for Unit
10、 MasonryE4 Practices for Force Verification of Testing MachinesE6 Terminology Relating to Methods of Mechanical Test-ingE 171 Specification for Atmospheres for Conditioning andTesting Flexible Barrier MaterialsE 575 Practice for Reporting Data from Structural Tests ofBuilding Constructions, Elements
11、, Connections, and As-semblies1This test method is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.13on Structural Performance of Connections in Building Constructions.Current edition approved Oct. 1, 2006. Published Octobe
12、r 2006. Originallyapproved in 1980. Last previous edition approved in 2000 as E 754 80 (2000).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document
13、 Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3. Terminology3.1 DefinitionsFor definitions of terms used in this testmethod, refer to Terminology E6.4. Summary of Test Method4.1 These procedures pro
14、vide for a static pullout test of a tieor anchor embedded in a hardened mortar joint between twomasonry units.5. Significance and Use5.1 This test method is intended to provide a simpleinexpensive means of generating conservative, comparativedata on pullout strengths of various ties and anchors used
15、 withdifferent types of masonry units and mortars. This test methodis recommended for such use until economical, improvedmethods can be developed to simulate service conditions moreinclusively.6. Apparatus6.1 Procedure A (Using Brick-Size Masonry Units):6.1.1 The testing machine shall conform to the
16、 requirementsof Practices E4.6.1.2 Auxiliary pulling apparatus is shown in Fig. 1 and Fig.2. These fixtures are provided with swivel joints and rollerbearings to eliminate lateral restraint and bending when apply-ing the pullout loads. The apparatus shall be designed to haveenough strength and stiff
17、ness to prevent its yielding (in order tominimize apparatus deformation) and to maintain uniformdistribution of the axially applied test loads until failure of thespecimen occurs.6.2 Procedure B (Using Block-Size Masonry Units)Apparatus for this procedure is shown in Fig. 3 and Fig. 4. Itsspecial pu
18、rpose is to avoid handling an unwieldy specimen inapparatus such as that used in Procedure A by applying pulloutloads to the specimen placed on a convenient work surface.The apparatus shall be of sufficient strength and stiffness tominimize bending deformations that would tend to promote aflexural b
19、ond failure of the mortar joint; and it shall have thecapacity to develop the pullout failure load of the fastenerwithout yielding.6.3 For both Procedures A and B, the apparatus is madefrom common rolled metal sections and other stock items. Theknockdown jig used for pulling the end of the fastenerp
20、rotruding from the masonry also serves as a reusable mold forcasting a gypsum head on that end of the fastener. The mold/jigis reassembled around the gypsum pulling head when testing.6.4 InstrumentationDisplacement of the fastener relativeto the masonry shall be measured by a dial gage or by anelect
21、ronic displacement transducer (for example, a linearvariable differential transformer (LVDT). The instrument usedshall be capable of reading 0.001 in. (0.025 mm) and beaccurate to 1 %.7. Test Specimen7.1 Sampling of Fasteners (Masonry Ties or Anchors)Test at least five specimens of a given type of f
22、astener for eachgiven combination of masonry constituent materials. Morespecimens may be needed depending on the variability of themasonry constituents. If necessary, determine suitable statisti-cal parameters to evaluate the composite variability and toFIG. 1 Procedure A Apparatus and SetupE 754 80
23、 (2006)2select the number of specimens needed for obtaining a givenminimum precision in determining the capacity of the fastener.7.2 Sampling and Testing of Masonry UnitsSelect repre-sentative masonry units and test according to applicablestandard test methods (Methods C 67 and C 140) to determineba
24、sic properties.7.3 Sampling and Testing of Mortar Use mortar that isrepresentative of that specified for the intended construction;or, for comparative research data, select one of the types ofmortar specified in Specification C 270. Determine the com-pressive strength of the mortar in accordance wit
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME75419802006STANDARDTESTMETHODFORPULLOUTRESISTANCEOFTIESANDANCHORSEMBEDDEDINMASONRYMORTARJOINTS 埋入

链接地址:http://www.mydoc123.com/p-533460.html