ASTM E747-2004 Standard Practice for Design Manufacture and Material Grouping Classification of Wire Image Quality Indicators (IQI) Used for Radiology《放射学用金属丝图像质量指示器的设计、制造和材料分组分类的标.pdf
《ASTM E747-2004 Standard Practice for Design Manufacture and Material Grouping Classification of Wire Image Quality Indicators (IQI) Used for Radiology《放射学用金属丝图像质量指示器的设计、制造和材料分组分类的标.pdf》由会员分享,可在线阅读,更多相关《ASTM E747-2004 Standard Practice for Design Manufacture and Material Grouping Classification of Wire Image Quality Indicators (IQI) Used for Radiology《放射学用金属丝图像质量指示器的设计、制造和材料分组分类的标.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 747 04Standard Practice forDesign, Manufacture and Material Grouping Classification ofWire Image Quality Indicators (IQI) Used for Radiology1This standard is issued under the fixed designation E 747; the number immediately following the designation indicates the year oforiginal adopti
2、on or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice2covers the design, material groupingclassification, and man
3、ufacture of wire image quality indica-tors (IQI) used to indicate the quality of radiologic images.1.2 This practice is applicable to X-ray and gamma-rayradiology.1.3 This practice covers the use of wire penetrameters as thecontrolling image quality indicator for the material thicknessrange from 6.4
4、 to 152 mm 0.25 to 6.0 in.1.4 The values stated in inch-pound units are to be regardedas standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health
5、 practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3B 139 Specification for Phosphor Bronze Rod, Bar, andShapesB 150 Specification for Aluminum Bronze Rod, Bar, andShapesB 161 Specification for Nickel Seamless Pipe and TubeB 1
6、64 Specification for Nickel-Copper Alloy Rod, Bar, andWireB 166 Specification for Nickel-Chromium-Iron Alloys(UNS N06600, N06601, and N06690) and Nickel-Chromium-Cobalt-Molybdenum Alloy (UNS N06617)Rod, Bar, and WireE 1025 Practice for Design, Manufacture, and MaterialGrouping Classification of Hole
7、-Type Image Quality Indi-cators (IQI) Used for RadiologyE 1316 Terminology for Nondestructive Examinations2.2 Other Standards:4EN 4261 Non-Destructive TestingImage Quality ofRadiographs-Part 1: Image Quality Indicators (Wire-Type)-Determination of Image Quality Value3. Terminology3.1 DefinitionsThe
8、definitions of terms in TerminologyE 1316, Section D, relating to gamma and X-radiology, shallapply to the terms used in this practice.4. Wire IQI Requirements4.1 The quality of all levels of examination shall be deter-mined by a set of wires conforming to the following require-ments:4.1.1 Wires sha
9、ll be fabricated from materials or alloysidentified or listed in accordance with 7.2. Other materials maybe used in accordance with 7.3.4.1.2 The IQI consists of sets of wires arranged in order ofincreasing diameter. The diameter sizes specified in Table 1 areestablished from a consecutive series of
10、 numbers taken ingeneral from the ISO/R 10 series. The IQI shall be fabricatedin accordance with the requirements specified in Figs. 1-8 andTables 1-3. IQIs previously manufactured to the requirementsof Annex A1 may be used as an alternate provided all otherrequirements of this practice are met.4.1.
11、3 Image quality indicator (IQI) designs other than thoseshown in Figs. 1-8 and Annex A1 are permitted by contractualagreement. If an IQI set as listed in Table 1 or Annex A1 ismodified in size, it must contain the grade number, set identity,and essential wire. It must also contain two additional wir
12、esthat are the next size larger and the next size smaller asspecified in the applicable set listed in Table 1.4.1.4 Each set must be identified using letters and numbersmade of industrial grade lead or of a material of similar1This practice is under the jurisdiction of ASTM Committee E07 on Nonde-st
13、ructive Testing and is the direct responsibility of Subcommittee E07.01 onRadiographic Practice and Penetrameters.Current edition approved January 1, 2004. Published February 2004. Originallyapproved in 1980. Last previous edition approved in 1997 as E 747 - 97.2For ASME Boiler and Pressure Vessel C
14、ode applications see related PracticeSE-747 in Section II of that Code.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe AST
15、M website.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.radiographic density. Identification shall be as shown on Figs.1-8 o
16、r Annex A1, unless otherwise specified by contractualagreement.4.1.5 European standard EN 462-1 contains similar provi-sions (with nominal differences-see table A1.1) for wire imagequality indicators as this standard (E 747). International usersof these type IQI standards who prefer the use of EN 46
17、2-1 fortheir particular applications should specify such alternateprovisions within separate contractual arrangements from thisstandard.5. Image Quality Indicator (IQI) Procurement5.1 When selecting IQIs for procurement, the followingfactors should be considered:5.1.1 Determine the alloy group(s) of
18、 the material to beexamined.5.1.2 Determine the thickness or thickness range of thematerial(s) to be examined.5.1.3 Select the applicable IQIs that represent the requiredIQI thickness(s) and alloy(s).6. Image Quality Levels6.1 The quality level required using wire penetrametersshall be equivalent to
19、 the 2-2T level of Practice E 1025 forhole-type IQIs unless a higher or lower quality level is agreedupon between purchaser and supplier. Table 4provides a list ofvarious hole-type IQIs and the diameter of wires of corre-sponding equivalent penetrameter sensitivity (EPS) with theapplicable 1T, 2T, a
20、nd 4T holes in the IQI. This table can beused for determining 1T, 2T, and 4T quality levels. AppendixX1 gives the equation for calculating other equivalencies ifneeded.6.2 In specifying quality levels, the contract, purchase order,product specification, or drawing should clearly indicate thethicknes
21、s of material to which the quality level applies. Carefulconsideration of required quality levels is particularly impor-tant.7. Material Groups7.1 General:7.1.1 Materials have been designated in eight groups basedon their radiographic absorption characteristics: groups 03, 02,and 01 for light metals
22、 and groups 1 through 5 for heavymetals.7.1.2 The light metal groups, magnesium (Mg), aluminum(Al), and titanium (Ti) are identified 03, 02, and 01 respec-tively, for their predominant alloying constituent. The materialsare listed in order of increasing radiation absorption.7.1.3 The heavy metal gro
23、ups, steel, copper-base, nickel-base, and kindred alloys are identified 1 through 5. Thematerials increase in radiation absorption with increasingnumerical designation.7.1.4 Common trade names or alloy designations have beenused for clarification of the pertinent materials.7.1.5 The materials from w
24、hich the IQI for the group are tobe made are designated in each case and these IQIs areapplicable for all materials listed in that group. In addition, anygroup IQI may be used for any material with a higher groupnumber, provided the applicable quality level is maintained.7.2 Materials Groups:7.2.1 M
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME7472004STANDARDPRACTICEFORDESIGNMANUFACTUREANDMATERIALGROUPINGCLASSIFICATIONOFWIREIMAGEQUALITYINDICATORSIQIUSEDFORRADIOLOGY

链接地址:http://www.mydoc123.com/p-533445.html