《ASTM E746-2007 895 Standard Practice for Determining Relative Image Quality Response of Industrial Radiographic Imaging Systems《工业X射线照相成像系统的相关图像质量特性曲线的测定用标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E746-2007 895 Standard Practice for Determining Relative Image Quality Response of Industrial Radiographic Imaging Systems《工业X射线照相成像系统的相关图像质量特性曲线的测定用标准实施规程》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 746 07Standard Practice forDetermining Relative Image Quality Response of IndustrialRadiographic Imaging Systems1This standard is issued under the fixed designation E 746; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisi
2、on, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This standard provides a practice whereby industrialradiographic imaging systems may be comparatively
3、 assessedusing the concept of relative image quality response (RIQR).The RIQR method presented within this practice is based uponthe use of equivalent penetrameter sensitivity (EPS) describedwithin Practice E 1025 and subsection 5.2 of this practice.Figure 1 illustrates a relative image quality indi
4、cator (RIQI)that has four different steel plaque thicknesses (.015, .010,.008, and .005 in.) sequentially positioned (from top to bottom)on a34-in. thick steel plate. The four plaques contain a total of14 different arrays of penetrameter-type hole sizes designed torender varied conditions of thresho
5、ld visibility ranging from1.92 % EPS (at the top) to .94 % EPS (at the bottom) whenexposed to nominal 200 keV X-ray radiation. Each “EPS”array consists of 30 identical holes; thus, providing the userwith a quantity of threshold sensitivity levels suitable forrelative image qualitative response compa
6、risons.1.2 This practice is not intended to qualify the performanceof a specific radiographic technique nor for assurance that aradiographic technique will detect specific discontinuities in aspecimen undergoing radiographic examination. This practiceis not intended to be used to classify or derive
7、performanceclassification categories for radiographic imaging systems. Forexample, performance classifications of radiographic film sys-tems may be found within Test Method E 1815.1.3 This practice contains an alternate provision wherebyindustrial radiographic imaging systems may be comparativelyass
8、essed using Lucite plastic material exposed to nominal 30keV X-ray radiation. The RIQI for this alternate evaluation isalso illustrated in Fig. 1, except the plaque and base platematerials are constructed of Lucite plastic in lieu of steel. EPSvalues for Lucite plastic are provided in Section 5 base
9、d uponthe use of a 138-in. thick Lucite base plate. For high-energyX-ray applications (4 to 25 MeV), Test Method E 1735provides a similar RIQR standard practice.1.4 The values stated in SI are to be regarded as thestandard.1.5 This standard does not purport to address all of thesafety concerns, if a
10、ny, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2B 152/B 152M Specification for Copper Sheet, Stri
11、p, Plate,and Rolled BarE 999 Guide for Controlling the Quality of Industrial Ra-diographic Film ProcessingE 1025 Practice for Design, Manufacture, and MaterialGrouping Classification of Hole-Type Image Quality Indi-cators (IQI) Used for RadiologyE 1079 Practice for Calibration of Transmission Densit
12、om-etersE 1316 Terminology for Nondestructive ExaminationsE 1735 Test Method for Determining Relative Image Qual-ity of Industrial Radiographic Film Exposed toX-Radiation from 4 to 25 MeVE 1815 Test Method for Classification of Film Systems forIndustrial RadiographyE 2002 Practice for Determining To
13、tal Image Unsharpnessin Radiology2.2 ANSI Standard3:ANSI PH2.19 Photography Density Measurements-Part 2:Geometric Conditions for Transmission Density2.3 ISO Standards3:ISO 5-2 Photography Density Measurements-Part 2: Geo-metric Conditions for Transmission DensityISO 7004 Photography- Industrial Radi
14、ographic Film, De-termination of ISO Speed, ISO average gradient, and ISO1This practice is under the jurisdiction of ASTM Committee E07 on Nonde-structive Testing and is the direct responsibility of Subcommittee E07.01 onRadiology (X and Gamma) Method.Current edition approved Dec. 1, 2007. Published
15、 January 2008. Originallyapproved in 1980. Last previous edition approved in 2002 as E746 - 02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Documen
16、t Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Copyright by ASTM Intl (
17、all rights reserved); Mon Mar 10 23:10:39 EST 2008Downloaded/printed byGuo Dehua (CNIS) pursuant to License Agreement. No further reproductions authorized.gradients G2 and G4 when exposed to X- and gamma-radiation3. Terminology3.1 DefinitionsThe definitions of terms relating to gammaand X-radiology
18、in Terminology E 1316 shall apply to termsused in this practice.3.2 Definitions of Terms Specific to This Standard:3.2.1 detectoran imaging device used to store a radio-graphic latent image or directly convert ionizing radiation intoelectrical signals in proportion to the quantity of radiationabsorb
19、ed.3.2.2 cassettea device that is either flexible or rigid usedto hold or protect a detector3.2.3 Relative Image Quality Indicator (RIQI)an imagequality measuring device that is capable of determining mean-ingful differences between two or more radiographic imagingsystems or changes of individual co
20、mponents of radiographicimaging systems.3.2.4 pixel intensity value (PV)a positive integer numeri-cal value of gray scale level of a picture data element (pixel)directly proportional with originating digital image data values.3.2.4.1 DiscussionPV is directly related to radiation dosereceived by a di
21、gital detector, that is, PV is “0” if radiation dosewas “0”. The number of available PV integers is associatedwith gray scale bit depth of the digital image. For example: a12-bit gray scale image will have a range from “0” to “4095”levels (shades) of gray (4096 total pixel value integers) andwill be
22、come saturated when PV reaches “4095”.4. Significance and Use4.1 This standard provides a practice for RIQR evaluationsof film and non-film imaging systems when exposed throughsteel or plastic materials. Three alternate data evaluationmethods are provided in Section 9. Determining RIQR requiresthe c
23、omparison of at least two radiographs or radiographicprocesses whereby the relative degree of image quality differ-ence may be determined using the EPS plaque arrangement ofStep Identification Shim Thickness, mm (in.) Hole Identification Hole Size, mm (in.)15 0.38 6 0.012 (0.015 6 0.0005) 32 0.81 6
24、0.025 (0.032 6 0.001)10 0.25 6 0.012 (0.010 6 0.0005) 31 0.79 6 0.025 (0.031 6 0.001)8 0.20 6 0.012 (0.008 6 0.0005) 28 0.71 6 0.025 (0.028 6 0.001)5 0.13 6 0.012 (0.005 6 0.0005) 25 0.64 6 0.025 (0.025 6 0.001)23 0.58 6 0.025 (0.023 6 0.001)20 0.50 6 0.025 (0.020 6 0.001)Hole Spacing (horizontal):
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME7462007895STANDARDPRACTICEFORDETERMININGRELATIVEIMAGEQUALITYRESPONSEOFINDUSTRIALRADIOGRAPHICIMAGINGSYSTEMS

链接地址:http://www.mydoc123.com/p-533441.html