《ASTM E734-1980(2015) 4504 Standard Specification for Disposable Glass Blood Sample Capillary Tube (Microhematocrit)《一次性玻璃血样毛细管 (微量血细胞比容) 的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM E734-1980(2015) 4504 Standard Specification for Disposable Glass Blood Sample Capillary Tube (Microhematocrit)《一次性玻璃血样毛细管 (微量血细胞比容) 的标准规格》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E734 80 (Reapproved 2015)Standard Specification forDisposable Glass Blood Sample Capillary Tube(Microhematocrit)1This standard is issued under the fixed designation E734; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、 the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers disposable glass blood samplecapillary tubes for use in microhematocrit procedu
3、res.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.2. Referenced Documents2.1 ASTM Standards:2E438 Specification for Glasses in Laboratory Apparatus2.2 Other Standard:USP XIX United States Pharmacopeia3. Terminology3.1 Defi
4、nitions of Terms Specific to This Standard:3.1.1 disposable capillary tubes, nin accordance with thisspecification and the expected product performance expressedin this standard, those capillary tubes which are to be used onetime only. Any institution or individual who reuses a dispos-able capillary
5、 tube must bear full responsibility for its safetyand effectiveness.4. Classification4.1 This specification covers two different disposable glasssample capillary tubes as follows:Type ICoated with heparin.Type IIUncoated.5. Materials5.1 GlassThe pipets made to this specification shall befabricated f
6、rom borosilicate glass, Type I, Class B, or soda-lime glass, Type II, in accordance with Specification E438.5.2 HeparinHeparin shall be of ammonium salt isolatedfrom the lungs or intestinal mucosa of beef or pork origin. Theheparin potency shall be 1 mg of ammonium heparin com-pound which shall be e
7、qual to at least 60 United StatesPharmacopeia (USP) units. Dry or wet heparin may be appliedto the tube.6. Physical Requirements6.1 DesignThe capillary tubes shall be straight and openat both ends without lip or constriction. The capillary tube maybe lightly firepolished on one end. The bore of the
8、tube shall beuniform and not vary in excess of 0.025 mm in 75 mm.6.2 DimensionsType I and Type II capillary tubes shallhave a length of 75 6 0.5 mm. Inside diameter shall be from1.07 to 1.24 mm. Wall thickness shall be 0.20 + 0.03, 0.02mm, as specified in Fig. 1.6.3 WorkmanshipThe capillary tubes sh
9、all be free ofdefects that noticeably detract from their appearance or impairtheir serviceability. The capillary tube shall be free of lint, orsignificant foreign matter, loose or embedded, when viewedunder normal room lighting. The tube ends shall be cutapproximately 90 to the tube axis and shall n
10、ot be cracked orhave jagged ends or chips that enter the bore of the tubing.6.4 Color CodingEach capillary tube shall be color codedto identify the tube as coated with heparin or uncoated. Type I,heparin coated, shall have a red band and Type II, uncoated,shall have a blue band. The location of the
11、red or blue bandshall be as specified in Fig. 1.6.5 CapillarityThe capillary tube shall be capable ofdrawing sheep plasma or human whole blood to a level within20 mm from the far end of the tube when tested as specified in7.1.6.6 Fluidity (Type I, Heparinized, only)Coagulation of thesheep plasma or
12、human whole blood shall not be evident whenviewed under normal room lighting and tested as specified in7.2.6.7 Lot or Control NumberA lot or control number shallbe indicated on the capillary tube unit container and on theintermediate package of containers. This lot or control numbershall be traceabl
13、e to the origin (raw material purchases) of themanufacturing record.1This specification is under the jurisdiction of ASTM Committee E41 onLaboratory Apparatus and is the direct responsibility of Subcommittee E41.01 onLaboratory Ware and Supplies.Current edition approved June 1, 2015. Published July
14、2015. Originally approvedin 1980. Last previous edition approved in 2010 as E734 80 (2010). DOI:10.1520/E0734-80R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to
15、the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16.8 Resistance to Centrifugal ForceResistance to capil-lary tube centrifugal force shall be such that no breakageresults when the t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME734198020154504STANDARDSPECIFICATIONFORDISPOSABLEGLASSBLOODSAMPLECAPILLARYTUBEMICROHEMATOCRIT 一次性

链接地址:http://www.mydoc123.com/p-533419.html