ASTM E672-1987(2011) 4375 Standard Specification for Disposable Glass Micropipets《一次性玻璃微量吸管的标准规格》.pdf
《ASTM E672-1987(2011) 4375 Standard Specification for Disposable Glass Micropipets《一次性玻璃微量吸管的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM E672-1987(2011) 4375 Standard Specification for Disposable Glass Micropipets《一次性玻璃微量吸管的标准规格》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E672 87 (Reapproved 2011)Standard Specification forDisposable Glass Micropipets1This standard is issued under the fixed designation E672; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A num
2、ber in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification covers two different types of dispos-a
3、ble micropipets, calibrated “to contain,” used in measuringmicrolitre volumes of liquids.1.2 The values stated in SI units are to be regarded as thestandard.1.3 The following precautionary caveat pertains only toparagraph 9.1.1 of this specification. This standard does notpurport to address all of t
4、he safety concerns, if any, associatedwith its use. It is the responsibility of the user of this standardto establish appropriate safety and health practices anddetermine the applicability of regulatory limitations prior touse.2. Referenced Documents2.1 ASTM Standards:2E438 Specification for Glasses
5、 in Laboratory Apparatus2.2 ISO Standard:3R-1769 Color Coding for Pipets3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 accuracythe closeness of agreement between thenominal value and the mean volume, obtained by applying thetest procedure specified in 9.4.1. It is quantified
6、by theinaccuracy of the mean (bias).3.1.2 disposable micropipetsuch micropipets will only beexpected to provide their specified performance during theiroriginal use or operation.NOTE 1The descriptions of “accuracy” and “repeatability” apply onlyin cases where the distributions are Gaussian.3.1.3 rep
7、eatabilitythe closeness of agreement between theindividual volumes obtained by applying the test procedurespecified in 9.4.2. It is quantified by the imprecision.4. Classification4.1 This specification covers two different pipet designs asfollows:4.1.1 Type IDisposable micropipets with calibration l
8、ineand color coding (see Fig. 1 and Table 1).4.1.2 Type IIDisposable micropipets void of markings(see Fig. 2 and Table 2).NOTE 2Type I pipets were originally specified by the Department ofDefense under MIL-P-36722.5. Materials and Manufacture5.1 The pipets made to these specifications shall be fabri
9、-cated from borosilicate glass, Type I, Class A or B or soda limeglass, Type II, in accordance with Specification E438.6. Dimensions and Permissible Variations6.1 DesignPipets shall be of one piece construction inaccordance with Table 1 and Table 2 for shape, dimensions,and permissible variations. A
10、ny cross-section of the pipet,taken in a plane perpendicular to the longitudinal axis, shall becircular.6.2 CapacityThe pipet capacity shall be stated on thepackage label, expressed as L(microlitre); this shall be knownas the stated capacity, V1, in making subsequent calculations.The expected deviat
11、ion from the stated capacity shall beexpressed as accuracy and coefficient of variation and shall betested for capacity as specified in 9.1. The unit, microlitre, L,may be considered as equivalent to 0.001 cm3.1This specification is under the jurisdiction of ASTM Committee E41 onLaboratory Apparatus
12、 and is the direct responsibility of Subcommittee E41.01 onApparatus.Current edition approved Dec. 1, 2011. Published December 2011. Originallyapproved in 1978. Last previous edition approved in 2006 as E672 87 (2006).DOI: 10.1520/E0672-87R11.2For referenced ASTM standards, visit the ASTM website, w
13、ww.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.
14、ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.2.1 Accuracy (see 4.1)The accuracy shall be determinedas specified in 9.4 and shall be within the limits given in Table1 and Table 2.6.2.2 Coeffcient of Variation (see sectio
15、n 4.2)The coeffi-cient of variation shall be determined as specified in 9.4 andshall be within the limits given in Table 1 and Table 2.6.3 Capacity MarkPipets in Fig. 1 shall have a capacityline that is calibrated “to contain” a volume of liquid at 20C.The capacity line shall be 0.3 to 0.5 mm wide a
16、nd shallcompletely encircle the pipet in a plane perpendicular to itslongitudinal axis.6.4 Identification Markings:6.4.1 Type IThe pipets in Fig. 1 shall be identified forcapacity by a color code marking on each pipet consisting ofone or two color bands (see Table 1). For a code consisting ofone ban
17、d, the band shall be from 2 to 6 mm wide; for a codeconsisting of two bands, each band shall be 2 to 6 mm wide andseparated with a space of 2 to 6 mm. The color code band, orbands, shall completely encircle the pipet in a plane perpen-dicular to its longitudinal axis. The location of color band, orF
18、IG. 1 Type I PipetTABLE 1 Dimensions for Type I PipetStated Capacity,LColor CodeMinimum Di-ameter A, mmMinimum WallB, mmMaximum Volumetric DeviationAccuracy, %Coefficient ofVariation, %5 white 1.0 0.35 61.0 1.510 orange 1.0 0.25 60.5 1.020 black 1.1 0.25 60.5 1.025 2 white 1.1 0.25 60.5 1.050 green
19、1.3 0.20 60.5 1.0100 blue 1.6 0.20 60.5 1.0200 red 2.2 0.20 60.5 1.0FIG.2TypeIIPipetE672 87 (2011)2bands, shall be as specified in Fig. 1 with the selection of color,to designate capacity, according to ISO RecommendationR-1769.6.4.2 Type IIPipets in Fig. 2 are devoid of any markingsand shall be iden
20、tified for capacity on the package label.7. Workmanship, Finish and Appearance7.1 The pipets in Fig. 1 and Fig. 2 shall be free of defectsthat will detract from their appearance or may impair theirserviceability. The pipets shall be free of significant foreignmatter, loose or embedded lint or chips
21、that affect the bore, orstains when viewed under normal room lighting.7.2 The calibration line and color code on Type I pipets shallbe applied to the glass pipet at locations specified in Fig. 1. Thecalibration line shall be sufficiently deposited on the glass toenable the setting of a meniscus and
22、the color band shall besufficiently deposited on the glass to identify the pipet as to itsstated volume.8. Reading and Setting the Meniscus8.1 Reading a Liquid Meniscus (Type I only)For allpipets, the reading is made on the lowest point of the meniscus.In order that the lowest point may be observed,
23、 it is necessaryto place a shade of some dark material immediately below andbehind the meniscus, which renders the profile of the meniscusdark and clearly visible against a light background.8.1.1 Setting a Liquid MeniscusSetting of the meniscusshall be performed by one of the following methods. Wher
24、everpractical, the meniscus should descend to the position ofsetting.8.1.1.1 Method AThe position of the lowest point of themeniscus with reference to the graduation line is horizontallytangent to the plane of the upper edge of the graduation line.The position of the meniscus is obtained by having t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME672198720114375STANDARDSPECIFICATIONFORDISPOSABLEGLASSMICROPIPETS 一次性 玻璃 微量 吸管 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-533283.html