1、Designation: E 672 87 (Reapproved 2006)Standard Specification forDisposable Glass Micropipets1This standard is issued under the fixed designation E 672; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A n
2、umber in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification covers two different types of dispo
3、s-able micropipets, calibrated “to contain,” used in measuringmicrolitre volumes of liquids.1.2 The values stated in SI units are to be regarded as thestandard.1.3 The following precautionary caveat pertains only toparagraph 9.1.1 of this specification. This standard does notpurport to address all o
4、f the safety concerns, if any, associatedwith its use. It is the responsibility of the user of this standardto establish appropriate safety and health practices anddetermine the applicability of regulatory limitations prior touse.2. Referenced Documents2.1 ASTM Standards:2E 438 Specification for Gla
5、sses in Laboratory Apparatus2.2 ISO Standard:3R 1769 Color Coding for Pipets3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 accuracythe closeness of agreement between thenominal value and the mean volume, obtained by applying thetest procedure specified in 9.4.1. It is quantif
6、ied by theinaccuracy of the mean (bias).3.1.2 disposable micropipetsuch micropipets will only beexpected to provide their specified performance during theiroriginal use or operation.NOTE 1The descriptions of “accuracy” and “repeatability” apply onlyin cases where the distributions are Gaussian.3.1.3
7、 repeatabilitythe closeness of agreement between theindividual volumes obtained by applying the test procedurespecified in 9.4.2. It is quantified by the imprecision.4. Classification4.1 This specification covers two different pipet designs asfollows:4.1.1 Type IDisposable micropipets with calibrati
8、on lineand color coding (see Fig. 1 and Table 1).4.1.2 Type IIDisposable micropipets void of markings(see Fig. 2 and Table 2).NOTE 2Type I pipets were originally specified by the Department ofDefense under MIL-P-36722.5. Materials and Manufacture5.1 The pipets made to these specifications shall be f
9、abri-cated from borosilicate glass, Type I, Class A or B or soda limeglass, Type II, in accordance with Specification E 438.6. Dimensions and Permissible Variations6.1 DesignPipets shall be of one piece construction inaccordance with Table 1 and Table 2 for shape, dimensions,and permissible variatio
10、ns. Any cross-section of the pipet,taken in a plane perpendicular to the longitudinal axis, shall becircular.6.2 CapacityThe pipet capacity shall be stated on thepackage label, expressed as L(microlitre); this shall be knownas the stated capacity, V1, in making subsequent calculations.The expected d
11、eviation from the stated capacity shall beexpressed as accuracy and coefficient of variation and shall betested for capacity as specified in 9.1. The unit, microlitre, L,may be considered as equivalent to 0.001 cm3.6.2.1 Accuracy (see 4.1)The accuracy shall be determinedas specified in 9.4 and shall
12、 be within the limits given in Table1 and Table 2.6.2.2 Coeffcient of Variation (see section 4.2)The coeffi-cient of variation shall be determined as specified in 9.4 andshall be within the limits given in Table 1 and Table 2.1This specification is under the jurisdiction of ASTM Committee E41 onLabo
13、ratory Apparatus and is the direct responsibility of Subcommittee E41.01 onApparatus.Current edition approved Nov. 1, 2006. Published December 2006. Originallyapproved in 1978. Last previous edition approved in 2001 as E 672 87 (2001)e1.2For referenced ASTM standards, visit the ASTM website, www.ast
14、m.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.o
15、rg.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.3 Capacity MarkPipets in Fig. 1 shall have a capacityline that is calibrated “to contain” a volume of liquid at 20C.The capacity line shall be 0.3 to 0.5 mm wide and shallcompletel
16、y encircle the pipet in a plane perpendicular to itslongitudinal axis.6.4 Identification Markings:6.4.1 Type IThe pipets in Fig. 1 shall be identified forcapacity by a color code marking on each pipet consisting ofone or two color bands (see Table 1). For a code consisting ofone band, the band shall
17、 be from 2 to 6 mm wide; for a codeconsisting of two bands, each band shall be 2 to 6 mm wide andseparated with a space of 2 to 6 mm. The color code band, orbands, shall completely encircle the pipet in a plane perpen-dicular to its longitudinal axis. The location of color band, orbands, shall be as
18、 specified in Fig. 1 with the selection of color,to designate capacity, according to ISO RecommendationR-1769.6.4.2 Type IIPipets in Fig. 2 are devoid of any markingsand shall be identified for capacity on the package label.7. Workmanship, Finish, and Appearance7.1 The pipets in Fig. 1 and Fig. 2 sh
19、all be free of defectsthat will detract from their appearance or may impair theirserviceability. The pipets shall be free of significant foreignFIG. 1 Type I PipetTABLE 1 Dimensions for Type I PipetStated Capacity,LColor CodeMinimum Di-ameter A, mmMinimum WallB, mmMaximum Volumetric DeviationAccurac
20、y, %Coefficient ofVariation, %5 white 1.0 0.35 61.0 1.510 orange 1.0 0.25 60.5 1.020 black 1.1 0.25 60.5 1.025 2 white 1.1 0.25 60.5 1.050 green 1.3 0.20 60.5 1.0100 blue 1.6 0.20 60.5 1.0200 red 2.2 0.20 60.5 1.0FIG.2TypeIIPipetE 672 87 (2006)2matter, loose or embedded lint or chips that affect the
21、 bore, orstains when viewed under normal room lighting.7.2 The calibration line and color code on Type I pipets shallbe applied to the glass pipet at locations specified in Fig. 1. Thecalibration line shall be sufficiently deposited on the glass toenable the setting of a meniscus and the color band
22、shall besufficiently deposited on the glass to identify the pipet as to itsstated volume.8. Reading and Setting the Meniscus8.1 Reading a Liquid Meniscus (Type I only)For allpipets, the reading is made on the lowest point of the meniscus.In order that the lowest point may be observed, it is necessar
23、yto place a shade of some dark material immediately below andbehind the meniscus, which renders the profile of the meniscusdark and clearly visible against a light background.8.1.1 Setting a Liquid MeniscusSetting of the meniscusshall be performed by one of the following methods. Whereverpractical,
24、the meniscus should descend to the position ofsetting.8.1.1.1 Method AThe position of the lowest point of themeniscus with reference to the graduation line is horizontallytangent to the plane of the upper edge of the graduation line.The position of the meniscus is obtained by having the eye inthe sa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME67219872006STANDARDSPECIFICATIONFORDISPOSABLEGLASSMICROPIPETS 处置 玻璃 微量 滴管 PDF

链接地址:http://www.mydoc123.com/p-533282.html