《ASTM E668-2005 Standard Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices《电子器.pdf》由会员分享,可在线阅读,更多相关《ASTM E668-2005 Standard Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices《电子器.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 668 05Standard Practice forApplication of Thermoluminescence-Dosimetry (TLD)Systems for Determining Absorbed Dose in Radiation-Hardness Testing of Electronic Devices1This standard is issued under the fixed designation E 668; the number immediately following the designation indicates t
2、he year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the D
3、epartment of Defense.1. Scope1.1 This practice covers procedures for the use of thermolu-minescence dosimeters (TLDs) to determine the absorbed dosein a material irradiated by ionizing radiation. Although someelements of the procedures have broader application, thespecific area of concern is radiati
4、on-hardness testing of elec-tronic devices. This practice is applicable to the measurementof absorbed dose in materials irradiated by gamma rays, Xrays, and electrons of energies from 12 to 60 MeV. Specificenergy limits are covered in appropriate sections describingspecific applications of the proce
5、dures. The range of absorbeddose covered is approximately from 102to 104Gy (1 to 106rad), and the range of absorbed dose rates is approximatelyfrom 102to 1010Gy/s (1 to 1012rad/s). Absorbed dose andabsorbed dose-rate measurements in materials subjected toneutron irradiation are not covered in this p
6、ractice. Further, theportion of these procedures that deal with electron irradiationare primarily intended for use in parts testing. Testing ofdevices as a part of more massive components such aselectronics boards or boxes may require techniques outside thescope of this practice.NOTE 1The purpose of
7、 the upper and lower limits on the energy forelectron irradiation is to approach a limiting case where dosimetry issimplified. Specifically, the dosimetry methodology specified requires thatthe following three limiting conditions be approached: (a) energy loss ofthe primary electrons is small, (b) s
8、econdary electrons are largely stoppedwithin the dosimeter, and (c) bremsstrahlung radiation generated by theprimary electrons is largely lost.1.2 This standard dose not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standar
9、d to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 170 Terminology Relating to Radiation Measurementsand DosimetryE 380 Practice for Use of the International System of Units(SI)
10、(the Modernized Metric System)E 666 Practice for CalculatingAbsorbed Dose from Gammaor X Radiation2.2 International Commission on Radiation Units andMeasurements (ICRU) Reports:3ICRU Report 14Radiation Dosimetry: X Rays andGamma Rays with Maximum Photon Energies Between0.6 and 50 MeVICRU Report 17Ra
11、diation Dosimetry: X Rays Generatedat Potentials of 5 to 150 keVICRU Report 21Radiation Dosimetry: Electrons with Ini-tial Energies Between 1 and 50 MeVICRU Report 31Average Energy Required to Produce anIon PairICRU Report 33Radiation Quantities and UnitsICRU Report 34The Dosimetry of Pulsed Radiati
12、onICRU Report 37Stopping Powers for Electrons andPositrons3. Terminology3.1 Definitions:3.1.1 absorbed dose, Dthe quotient of debydm, where deis the mean energy imparted by ionizing radiation to the matterin a volume element and dm is the mass of matter in thatvolume element.D 5dedm(1)1This practice
13、 is under the jurisdiction of ASTM Committee E10 on NuclearTechnology and Applications and is the direct responsibility of SubcommitteeE10.07 on Radiation Dosimetry for Radiation Effects on Materials and Devices onMaterials and Devices.Current edition approved June 1, 2005. Published June 2005. Orig
14、inallyapproved in 1978. Last previous edition approved in 2000 as E 668 00.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe
15、 ASTM website.3Available from International Commission on Radiation Units and Measure-ments, 7910, Woodmont Ave., Suite 800, Bethesda, MD 20814.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Previously, the special unit of absorbed
16、dose was the rad;however, the gray (Gy) has been adopted as the official SI unit(see Practice E 380).1Gy5 1Jkg215 102rad (2)3.1.2 absorbed-dose ratethe absorbed dose per unit timeinterval.3.1.3 annealingthermal treatment of a TLD prior toirradiation or prior to readout.3.1.3.1 DiscussionPre-irradiat
17、ion annealing of TLDs isusually done to erase the effects of previous irradiation and toreadjust the sensitivity of the phosphor; pre-readout annealingusually is done to reduce low-temperature TLD response.3.1.4 calibration conditionsthe normal environmentalconditions prevailing during routine calib
18、ration irradiationssuch as the ambient temperature, humidity, and lighting.3.1.5 equilibrium absorbed dosethe absorbed dose atsome incremental volume within the material which thecondition of electron equilibrium (as many electrons of a givenenergy enter as leave the volume) exists (1)4(see Appendix
19、X1).3.1.6 exposure, Xthe quotient of dQ by dm, where dQ isthe absolute value of the total charge of the ions of one signproduced in air when all the electrons (negatrons and positrons)liberated by photons in a volume element of air having massdm are completely stopped in air.X 5dQdm(3)UnitCkg13.1.6.
20、1 DiscussionFormerly the special unit of exposurewas the roentgen (R).1 R 5 2.58 3 1021C kg21exactly! (4)3.1.7 primary electronsfor the case of electron irradia-tion, the electrons introduced into the device under test by theirradiation source.3.1.8 secondary-electron equilibriumfor the case of elec
21、-tron irradiation, the condition where as many secondaryelectrons of a given energy enter a given volume as leave it.3.1.9 secondary-electron equilibrium absorbed doseforthe case of electron irradiation, the absorbed dose at someincremental volume within the material in which the conditionof seconda
22、ry-electron equilibrium exists.3.1.9.1 DiscussionAdditional definitions can be found inICRU Report 33.3.1.10 secondary electronsfor the case of electron irra-diation, electrons knocked out of the electron shells of thematerial being irradiated by the primary electron. For the caseof photon irradiati
23、on, energetic electrons (photoelectrons,Auger electrons, and Compton electrons) produced within thematerial being irradiated by the action of the incident photons.3.1.10.1 DiscussionSecondary electrons are produced bythe interaction of the primary electrons with the atoms of thematerial being irradi
24、ated. This interaction is a principal meansof energy loss for the primary electrons. The kinetic energy ofa secondary electron is typically much lower than that of theprimary electron which creates it.3.1.11 test conditionsthe normal environmental condi-tions prevailing during routine hardness-test
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME6682005STANDARDPRACTICEFORAPPLICATIONOFTHERMOLUMINESCENCEDOSIMETRYTLDSYSTEMSFORDETERMININGABSORBEDDOSEINRADIATIONHARDNESSTESTINGOFELECTRONICDEVICES

链接地址:http://www.mydoc123.com/p-533274.html