ASTM E619-1984(2003) Standard Practice for Evaluating Foreign Odors in Paper Packaging《纸包装材料中异样气味评价的标准实施规程》.pdf
《ASTM E619-1984(2003) Standard Practice for Evaluating Foreign Odors in Paper Packaging《纸包装材料中异样气味评价的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E619-1984(2003) Standard Practice for Evaluating Foreign Odors in Paper Packaging《纸包装材料中异样气味评价的标准实施规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 619 84 (Reapproved 2003)Standard Practice forEvaluating Foreign Odors in Paper Packaging1This standard is issued under the fixed designation E 619; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last rev
2、ision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This practice covers the evaluation of odors
3、 in paperpackaging and establishes smelling and testing procedures fortrained sensory panels.1.2 This practice covers effective techniques for determin-ing the type and source of the odor and establishing the severityof contamination.1.3 The techniques used in this practice are applicable to allpape
4、r packaging products and to auxiliary components, such ascoatings, inks, and adhesives, as well as plastic materials usedin conjunction with paper.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this sta
5、ndard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Summary of Practice2.1 Under the leadership of the test supervisor, qualified andtrained subjects individually examine sample specimens by oneor more of the test pro
6、cedures described in this practice.Subjects judge the intensity of a perceived off-odor in terms ofa numerical rating scale and also attempt to give a qualitativedescription of the taint. The assembled observations are theninterpreted by the supervisor.3. Significance and Use3.1 UseThis practice sho
7、uld be used by panelists, trainedas described in ASTM STP 7582, under the direction of aknowledgeable supervisor.3.2 SignificanceThis practice can be used to evaluateindigenous and foreign odors in paper packaging materials asto type and intensity. A knowledgeable supervisor may be ableto determine
8、the source of a foreign odor from the informationobtained from this procedure.4. Sensory Test Panel Selection and Training4.1 GeneralSensory panel selection and training are de-scribed in STP 758 and in references therein.4.2 SizeThe test panel on a specific odor problem shouldconsist of at least fi
9、ve members and should render a minimumtotal of ten judgments per sample. A maximum of twelvesubjects may be used, if available. When possible, the subjectsshould be drawn from a larger pool of qualified panelists.4.3 SelectionThe important criteria in panel selection are:(a) normal ability to detect
10、 and identify odors and flavors; (b)ability to discriminate differences, and reproduce results; and(c) interest in the testing work for which the panelists are to betrained. Usually a suitable panel can be recruited from avail-able employees unless their number is limited. It is helpful ifpanel memb
11、ers have a scientific background, with someknowledge of chemistry or food technology; however, thisshould not be a criterion for selection. Nontechnical personnelhave often proved to be excellent panel members after appro-priate training. No willing and available person should beexcluded from consid
12、eration. Panel members should berequalified periodically.5. Testing Facilities and Apparatus5.1 GeneralAppropriate physical conditions for sensorypanel operations are described in STP 434.35.2 Testing RoomDetection of low levels of odor requiresa working space in which individual members of the pane
13、l canconcentrate on the task. The room should be comfortable as totemperature, humidity, and noise, and relatively free of labo-ratory industrial odors. If ambient odor levels are too high,testing of the samples must be transferred to another location.Interruptions and other distracting influences s
14、hould beavoided.5.3 Sample ContainersClean, dry, closed, odor-free con-tainers of appropriate sizes are needed for storing samples andfor confining specimens to develop maximum odor intensity orto test for taste transfer. Laboratory glassware, capped glassjars, and glass battery jars with plate glas
15、s lids are suitable forthis purpose. Rubber gaskets or stoppers should not be used.1This practice is under the jurisdiction of ASTM Committee E18 on SensoryEvaluation of Materials and Products and is the direct responsibility of Subcom-mittee E18.05 on Sensory ApplicationsGeneral.Current edition app
16、roved April 10, 2003. Published June 2003. Originallyapproved in 1984. Last previous edition approved in 1995 as E 619 84 (1995).2Guidelines for the Selection and Training of Sensory Evaluation Panels, ASTMSTP 758, ASTM, 1981.3Manual on Sensory Testing Methods, ASTM STP 434, ASTM, 1968.1Copyright AS
17、TM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Closures should provide adequate protection and contribute noodors of their own. Samples for storage may be wrappeddirectly in clean, low-odor, aluminum foil.6. Materials6.1 WaterMoistening of mater
18、ial to intensify odors or todevelop potential odors is frequently necessary. Tap water maybe used provided it is free of a chlorine smell or other residualodor. Bottled spring water or distilled water are suitablealternatives, if odorless. When necessary, water may be furtherpurified by filtering th
19、rough charcoal. In any case, the watershould be smelled and tasted before use to assure its suitability.6.2 Fatty MaterialsVarious materials containing oil or fatmay be used to pick up certain types of odors in transfer testssuch as those described in 7.4. Mineral oil (odorless), cream,butter, and m
20、ilk chocolate are recommended.6.3 Standard SamplesIt is good practice to include refer-ence materials if available. Commercially produced packagingmaterial representing either satisfactory or maximum permis-sible levels of odor are suitable. However, maintenance of suchstandards is usually difficult
21、, since age and storage conditionsmay drastically alter odor properties. As part of quality controlpractices, a schedule should be established for acquiring anddiscarding standard samples; when appropriate, this scheduleshould be accepted in advance by both manufacturer andpurchaser. (When a product
22、 normally contains traces of spe-cific solvents, gas chromatographic analysis is often used tohelp in selecting standards of uniform quality.)7. Methods for Preparing Test Specimens forExamination7.1 GeneralA single method will not suffice for thepreparation of test specimens because of the wide ran
23、ge ofmaterials that may be tested and the many types of odors thatmay be present. The more common methods are described inthis section. Each laboratory should select and standardize theparticular preparation procedures that seem best for specificproducts with which it is concerned.7.2 Methods that U
24、tilize Direct ExaminationThere aretwo categories of direct testing methods: immediate examina-tion without prior confinement and examination after sampleshave been confined appropriately in a closed container toenhance odor intensity.7.2.1 Direct Examination Without ConfinementThis ap-proach is usua
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME61919842003STANDARDPRACTICEFOREVALUATINGFOREIGNODORSINPAPERPACKAGING 纸包装 材料 异样 气味 评价 标准 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-533160.html