ASTM E611-2008(2015)e1 1795 Standard Test Methods for Low Concentrations of Diethlyene Glycol in Ethylene Glycol by Gas Chromatography《采用气相色谱法测定乙二醇中低浓度二甘醇的标准试验方法》.pdf
《ASTM E611-2008(2015)e1 1795 Standard Test Methods for Low Concentrations of Diethlyene Glycol in Ethylene Glycol by Gas Chromatography《采用气相色谱法测定乙二醇中低浓度二甘醇的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E611-2008(2015)e1 1795 Standard Test Methods for Low Concentrations of Diethlyene Glycol in Ethylene Glycol by Gas Chromatography《采用气相色谱法测定乙二醇中低浓度二甘醇的标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E611 08 (Reapproved 2015)1Standard Test Methods forLow Concentrations of Diethlyene Glycol in Ethylene Glycolby Gas Chromatography1This standard is issued under the fixed designation E611; the number immediately following the designation indicates the year oforiginal adoption or, in the
2、 case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEEditorial change was made in Subsection 1.3 in May 2016.1. Scope*1.1 These test methods are in
3、tended primarily for theanalysis of mixtures of ethylene and diethylene glycols inwhich the diethylene glycol concentration is 0.1 % or less.Both test methods should be applicable to higher concentra-tions of diethylene glycol, but precision and bias estimateshave been obtained only for 0.05 to 0.1
4、% diethylene glycol.NOTE 1Test Methods E202 describe another gas chromatographic testmethod applicable to mixtures of ethylene, diethylene, and triethyleneglycols and mixtures of propylene, dipropylene, and tripropylene glycolsin which one of the glycols is the principal component and the other twoa
5、re present in concentrations of 0.1 to 1 % each.NOTE 2Test Method E2409 describes another gas chromatographictest method for the determination of glycol impurities in mono-, di-, tri-and tetraethylene glycol (MEG, DEG, TEG and TeEG) in the range of 5to 3000 g/g.1.2 The two test methods are given as
6、follows:SectionsTest Method ANonderivative Method 5 to 13Test Method BDerivative Method 14 to 221.3 Review the current Safety Data Sheets (SDS) for de-tailed information concerning toxicity, first aid procedures, andsafety precautions for chemicals used in this standard.1.4 The values stated in SI u
7、nits are to be regarded asstandard. No other units of measurement are included in thisstandard with the exception of foot-pound units for apparatusdescriptions.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the use
8、r of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For a specificwarning statement, see 15.1.5.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterE180 Practice for Determining
9、the Precision of ASTMMethods for Analysis and Testing of Industrial and Spe-cialty Chemicals (Withdrawn 2009)3E202 Test Methods for Analysis of Ethylene Glycols andPropylene GlycolsE2409 Test Method for Glycol Impurities in Mono-, Di-, Tri-and Tetraethylene Glycol and in Mono- and DipropyleneGlycol(
10、Gas Chromatographic Method)2.2 Other Document:Manufacturers instruction manuals of gas chromatograph3. Significance and Use3.1 Either test method may be used to determine theconcentrations of diethylene glycol in ethylene glycol. Theconcentrations of the components are obtained by a normal-ization t
11、echnique, based on the assumption that all componentsare eluted under the conditions used. If all components shouldnot be eluted, the calculated concentrations will be erroneouslyhigh, with the major component showing the most significantabsolute error. Since water is not detected by these procedure
12、s,the results are on a water-free basis. Water may be determinedin accordance with the applicable sections of Test MethodsE202 and the gas chromatographic results corrected for thewater concentration.3.2 Both test methods are currently in industrial use. TestMethodAis the simpler of the two test met
13、hods because it doesnot require the preparation of derivatives prior to gas chro-matographic analysis. The results obtained by Test Method Aare slightly more accurate than those obtained by Test MethodB. With respect to precision there is no significant differencebetween the two test methods. Test M
14、ethod B has been1These test methods are under the jurisdiction of ASTM Committee E15 onIndustrial and Specialty Chemicalsand are the direct responsibility of SubcommitteeE15.02 on Product Standards.Current edition approved June 1, 2015. Published June 2015. Originallyapproved in 1977. Last previous
15、edition approved in 2008 as E61108. DOI:10.1520/E0611-08R15E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM websit
16、e.3The last approved version of this historical standard is referenced onwww.astm.org.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1reported to be suitable also for th
17、e analysis of a wide variety ofglycol ethers, but this use is beyond the scope of this standard.4. Purity of Reagents4.1 Reagent grade chemicals shall be used in all tests.Unless otherwise indicated, it is intended that all reagents shallconform to the specifications of the Committee on AnalyticalRe
18、agents of the American Chemical Society, where suchspecifications are available.4Other grades may be used, pro-vided it is first ascertained that the reagent is of sufficientlyhigh purity to permit its use without lessening the accuracy ofthe determination.4.2 Unless otherwise indicated, references
19、to water shall beunderstood to mean Type II or III reagent water conforming toSpecification D1193.TEST METHOD ANONDERIVATIVE METHOD5. Summary of Test Method5.1 The sample is injected into a gas chromatographiccolumn. The components are separated as they pass throughthe column with helium carrier gas
20、, their presence in theeffluent is detected by a flame ionization detector, and recordedas a chromatogram. The areas under the peaks due to thesample components are corrected by applying appropriatecalibration factors to obtain the composition of the sample ona weight percentage basis.6. Apparatus6.
21、1 Gas Chromatographic Instrument having the followingminimal characteristics (see Table 1).6.1.1 Sample Injection Port, with heater characteristicsnecessary for operation at 210C.6.1.2 Column Oven, capable of isothermal operation at168C.6.1.3 Detector, of conventional flame ionization type, ca-pable
22、 of operating at 168C. A conventional thermal conduc-tivity detector can be used, but sensitivity will be reduced andwater may be detected as a peak eluting with the pressure peakdue to sample injection, depending upon the concentration ofwater. The precision and bias statements in Section 13 are fo
23、rflame ionization detectors.6.1.4 Recorder, 0 to 1-mV range, that 1-s full scale deflec-tion with a chart speed of approximately 1.3 cm/min or otherconvenient speed that will produce a satisfactorychromatogram, and an attenuator switch to change the recorderrange as required to keep the chromatogram
24、 on scale.NOTE 3On instruments using electronic integration the attenuationfeature is not required.6.1.5 Column, 50 in. long,316 in. in outside diameter with awall thickness of 0.030 in. for copper or 0.020 in. for stainlesssteel construction; packed with 10 % polyethylene glycol onorange calcinated
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME61120082015E11795STANDARDTESTMETHODSFORLOWCONCENTRATIONSOFDIETHLYENEGLYCOLINETHYLENEGLYCOLBYGASCHROMATOGRAPHY

链接地址:http://www.mydoc123.com/p-533153.html