ASTM E608 E608M-2006 Standard Specification for Mineral-Insulated Metal-Sheathed Base Metal Thermocouples《矿物绝缘金属铠装基金属热电偶标准规范》.pdf
《ASTM E608 E608M-2006 Standard Specification for Mineral-Insulated Metal-Sheathed Base Metal Thermocouples《矿物绝缘金属铠装基金属热电偶标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM E608 E608M-2006 Standard Specification for Mineral-Insulated Metal-Sheathed Base Metal Thermocouples《矿物绝缘金属铠装基金属热电偶标准规范》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 608/E 608M 06Standard Specification forMineral-Insulated, Metal-Sheathed Base MetalThermocouples1This standard is issued under the fixed designation E 608/E 608M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the y
2、ear of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers the requirements for mineral-insulated, metal-sheathed base metal thermocouples for
3、indus-trial or high-reliability applications. It applies specifically tothermocouples fabricated from sheathed thermocouple mate-rial in accordance with Specification E 585/E 585M. Provi-sions are made for selecting thermoelements, insulation, andsheath material, and measuring junction configuration
4、, thermo-couple assembly length, and the type of transition or termina-tion.1.2 This specification also includes provisions for qualityassurance or verification program requirements, or both, as apurchasers option.1.3 The values stated in SI (metric) units or inch-poundunits may be regarded separate
5、ly as the standard. The valuesstated in each system are not the exact equivalents, and eachsystem shall be used independently of the other.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to
6、 establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 165 Test Method for Liquid Penetrant ExaminationE 220 Test Method for Calibration of Thermocouples ByComparison TechniquesE 230 Spe
7、cification and Temperature-Electromotive Force(EMF) Tables for Standardized ThermocouplesE 344 Terminology Relating to Thermometry and Hydrom-etryE 585/E 585M Specification for Compacted Mineral-Insulated, Metal-Sheathed, Base Metal ThermocoupleCableE 780 Test Method for Measuring the Insulation Res
8、istanceof Mineral-Insulated, Metal-Sheathed Thermocouples andThermocouple Cable at Room TemperatureE 839 Test Methods for Sheathed Thermocouples andSheathed Thermocouple Material2.2 AWS Standards:3A5.9 Specification for Corrosion-Resisting Chromium andChromium-Nickel Steel Welding Rods and Bare Elec
9、-trodesA5.14 Specification for Nickel and Nickel-Alloy BareWelding Rods and Electrodes3. Terminology3.1 DefinitionsThe definitions given in TerminologyE 344 shall apply to this specification.3.2 Definitions of Terms Specific to This Standard:3.2.1 common ungrounded junction, nmeasuring junc-tions wi
10、thin the same multi-pair thermocouple that are electri-cally isolated from the sheath but electrically connected to eachother.3.2.2 isolated ungrounded junction, nmeasuring junctionswithin the same multi-pair thermocouple that are electricallyisolated from the sheath and electrically isolated from e
11、achother.3.2.3 lot, na quantity of thermocouples manufacturedfrom the same continuous length of mineral-insulated, metal-sheathed thermocouple cable.3.2.4 sheathed thermocouple material, na combination oftwo or more continuous thermoelements embedded in ceramicinsulation compacted within a metal pro
12、tecting sheath.4. Significance and Use4.1 This specification describes the physical requirements ofmineral-insulated, metal-sheathed base metal thermocouplesand establishes suitable test criteria for them.1This specification is under the jurisdiction of ASTM Committee E20 onTemperature Measurement a
13、nd is the direct responsibility of Subcommittee E20.04on Thermocouples.Current edition approved Nov. 1, 2006. Published November 2006. Originallyapproved in 1977. Last previous edition approved in 2004 as E 608/E 608M -00 (2004).2For referenced ASTM standards, visit the ASTM website, www.astm.org, o
14、rcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American Welding Society (AWS), 550 NW LeJeune Rd.,Miami, FL 33126, http:/www.aws.org.1Copyright ASTM International,
15、 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.2 Standardized dimensional requirements, including ac-ceptable allowances for manufacturing variations, are given.4.3 Aset of standard tests to be applied to all thermocouplescovered by this specification are desc
16、ribed together with agroup of optional tests from which applicable additionalrequirements may be selected.4.4 WarningUsers should be aware that certain charac-teristics of thermocouples might change with time and use. Ifa thermocouples designed shipping, storage, installation, oroperating temperatur
17、e has been exceeded, the thermocouplesmoisture seal may have been compromised and may no longeradequately prevent the deleterious intrusion of water vapor.Consequently, the thermocouples condition established by testat time of manufacture may not apply later during an extendedperiod of use, and rete
18、sting may become necessary. In addition,inhomogeneities can develop in thermoelements because ofexposure to temperature, even in cases where maximumexposure temperatures have been lower than the suggestedupper temperature limits of Table 1. For this reason, calibrationof thermocouples destined for d
19、elivery to a customer is notrecommended (see S6.1). Because the EMF indication of anythermocouple depends upon the condition of the thermoele-ments along their entire length, as well as the temperatureprofile pattern in the region of any inhomogeneity, the EMFoutput of a used thermocouple will be un
20、ique to its installation.Because temperature profiles in calibration equipment areunlikely to duplicate those of the installation, removal of a usedthermocouple to a separate apparatus for calibration is notrecommended. Instead, in situ calibration by comparison to asimilar thermocouple known to be
21、good is often recommended.5. Ordering Information5.1 The purchase documents shall specify the followingoptions:5.1.1 The type and quantity of thermoelement pairs, and thetolerances, if other than standard (see 6.4 and 6.5).5.2 The nominal sheath diameter. See Table 1 or Specifica-tion E 585/E 585M f
22、or preferred nominal diameters.5.3 The type of ceramic insulation (MgO or Al2O3). SeeSpecification E 585/E 585M.5.4 The type of sheath material. See Table 2 or SpecificationE 585/E 585M.5.5 The type of measuring junction, Style G (grounded) orStyle U (ungrounded). See Figs. 1 and 2. If more than one
23、 pairof thermoelements is specified, Style U is further subdividedinto Style CU (common ungrounded) and Style IU (isolatedungrounded).4Do not specify Style G grounded junctions withType T thermoelements (see 6.3.2).5.6 The quantity, length, and length tolerance of eachthermocouple. See Figs. 3-6 for
24、 examples.5.7 The type and configuration of connection head, connec-tor, transition piece, or termination, and moisture seal requiredon the end opposite the measuring junction. See Figs. 3-6 forexamples. The minimum and maximum intended operatingtemperature of the connection head, transition, or ter
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME608E608M2006STANDARDSPECIFICATIONFORMINERALINSULATEDMETALSHEATHEDBASEMETALTHERMOCOUPLES 矿物 绝缘 金属

链接地址:http://www.mydoc123.com/p-533143.html