ASTM E603-2013 red 0625 Standard Guide for Room Fire Experiments《房间燃烧实验的标准指南》.pdf
《ASTM E603-2013 red 0625 Standard Guide for Room Fire Experiments《房间燃烧实验的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM E603-2013 red 0625 Standard Guide for Room Fire Experiments《房间燃烧实验的标准指南》.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E603 12bE603 13 An American National StandardStandard Guide forRoom Fire Experiments1This standard is issued under the fixed designation E603; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis guide has been written to assist those planning to conduct full-scale compartment fireexperiments. There are many issues that sh
3、ould be resolved before such an experimental program isinitiated, and this guide is written with the objective of identifying some of these issues and presentingconsiderations that will affect each choice of procedure.This guide deals with any or all stages of fire growth in a compartment. Whether i
4、t is a single- ormulti-room experiment, observations can be made from ignition to flashover or beyond full-roominvolvement.One major reason for conducting research on room fires is to learn about the room fire buildupprocess so the results of standard fire test methods can be related to performance
5、in full-scale roomfires, allowing the further refinement of these test methods or development of new ones.Another reason concerns computer fire modeling. Full-scale tests can generate data needed formodeling. Comparisons of modeling with full-scale test results can serve to validate the model.The va
6、rious results among room fire tests reflect different experimental conditions.The intent of thisguide is to identify these conditions and discuss their effects so meaningful comparisons can be madeamong the room fire experiments conducted by various organizations.1. Scope1.1 This guide addresses mea
7、ns of conducting full-scale fire experiments that evaluate the fire-test-response characteristics ofmaterials, products, or assemblies under actual fire conditions.1.2 It is intended as a guide for the design of the experiment and for the use and interpretation of its results. The guide is alsousefu
8、l for establishing laboratory conditions that simulate a given set of fire conditions to the greatest extent possible.1.3 This guide allows users to obtain fire-test-response characteristics of materials, products, or assemblies, which are usefuldata for describing or appraising their fire performan
9、ce under actual fire conditions.1.3.1 The results of experiments conducted in accordance with this guide are also useful elements for making regulatorydecisions regarding fire safety requirements. The use for regulatory purposes of data obtained from experiments conducted usingthis guide requires th
10、at certain conditions and criteria be specified by the regulating authority.1.4 The rationale for conducting room fire experiments in accordance with this guide is shown in 1.5-1.81.5 Room fire experiments are a means of generating input data for computer fire models and for providing output data wi
11、thwhich to compare modeling results.1.6 One of the major reasons for conducting room fire experiments is as an experimental means of assessing the potential firehazard associated with the use of a material or product in a particular application. This should be borne in mind when designingnonstandard
12、 experiments.1.7 A rationale for conducting room fire experiments is the case when smaller-scale fire tests inadequately represent end-useapplications.1.8 A further rationale for conducting room fire experiments is to verify the results obtained with smaller scale tests, tounderstand the scaling par
13、ameters for such tests.1 This guide is under the jurisdiction of ASTM Committee E05 on Fire Standards and is the direct responsibility of Subcommittee E05.21 on Smoke and CombustionProducts.Current edition approved Aug. 1, 2012Aug. 1, 2013. Published September 2012September 2013. Originally approved
14、 in 1977. Last previous edition approved in 2012 asE603 - 12a.E603 - 12b. DOI: 10.1520/E0603-12B.10.1520/E0603-13.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not
15、 be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Dr
16、ive, PO Box C700, West Conshohocken, PA 19428-2959. United States11.9 Room fire tests can be placed into four main categories: reconstruction, simulation, research, and standardization.1.10 This standard is used to measure and describe the response of materials, products, or assemblies to heat and f
17、lame undercontrolled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials,products, or assemblies under actual fire conditions1.11 This standard does not purport to address all of the safety concerns, if any, associated with its
18、 use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D4442 Test Methods for Direct Moisture Content Measurement of Wood and Wood
19、-Base MaterialsD4444 Test Method for Laboratory Standardization and Calibration of Hand-Held Moisture MetersD5424 Test Method for Smoke Obscuration of Insulating Materials Contained in Electrical or Optical Fiber Cables WhenBurning in a Vertical Cable Tray ConfigurationD5537 Test Method for Heat Rel
20、ease, Flame Spread, Smoke Obscuration, and Mass Loss Testing of Insulating MaterialsContained in Electrical or Optical Fiber Cables When Burning in a Vertical Cable Tray ConfigurationE176 Terminology of Fire StandardsE800 Guide for Measurement of Gases Present or Generated During FiresE906 Test Meth
21、od for Heat and Visible Smoke Release Rates for Materials and Products Using a Thermopile MethodE1321 Test Method for Determining Material Ignition and Flame Spread PropertiesE1354 Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen ConsumptionCalorimeterE
22、1355 Guide for Evaluating the Predictive Capability of Deterministic Fire ModelsE1537 Test Method for Fire Testing of Upholstered FurnitureE1590 Test Method for Fire Testing of MattressesE1822 Test Method for Fire Testing of Stacked ChairsE2067 Practice for Full-Scale Oxygen Consumption Calorimetry
23、Fire TestsE2257 Test Method for Room Fire Test of Wall and Ceiling Materials and Assemblies2.2 UL Standards:3UL 1040 Fire Test of Insulated Wall ConstructionUL 1715 Fire Test of Interior Finish Material2.3 ICBO Standards:4Uniform Building Code Standard UBC 8-2 Standard Test Method for Evaluating Roo
24、m Fire Growth Contribution of TextileWallcoveringsUniform Building Code Standard UBC 26-3 Room Fire Test Standard for Interior of Foam Plastic Systems2.4 FM Standard:5FM 4880 Large Scale Open Building Corner Test2.5 ISO Standards:6ISO 9705 Fire TestsFull Scale Room Fire Tests for Surface ProductsISO
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME6032013RED0625STANDARDGUIDEFORROOMFIREEXPERIMENTS 房间 燃烧 实验 标准 指南 PDF

链接地址:http://www.mydoc123.com/p-533132.html