《ASTM E580 E580M-2008ae1 923 Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions.pdf》由会员分享,可在线阅读,更多相关《ASTM E580 E580M-2008ae1 923 Standard Practice for Installation of Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels in Areas Subject to Earthquake Ground Motions.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 580/E 580M 08a1Standard Practice forInstallation of Ceiling Suspension Systems for AcousticalTile and Lay-in Panels in Areas Subject to EarthquakeGround Motions1This standard is issued under the fixed designation E 580/E 580M; the number immediately following the designation indicates
2、 the yearof original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the
3、Department of Defense.1NOTEFig. 4 was editorially updated in March 2009.1. Scope1.1 This practice covers installation of suspended ceilingsystems and their additional requirements for two groups ofbuildings that are constructed to resist the effects of earthquakemotions as defined by ASCE 7 and the
4、International BuildingCode. These groupings are for Seismic Design Category C andSeismic Design Categories D, E and F.1.2 The authority having jurisdiction shall determine theapplicability of this practice.1.3 Specification C 635 and Practice C 636 cover suspen-sion systems and their installation wi
5、thout special regard toseismic lateral restraint needs. They remain applicable andshall be followed when this practice is specified.1.4 This practice is not intended to stifle research anddevelopment of new products or methods. This practice is notintended to prevent the installation of any material
6、 or prohibitany design or method of construction not prescribed in thispractice, provided that any such alternative has been substan-tiated by verifiable engineering data or full-scale dynamictesting that is acceptable to the authority having jurisdiction.1.5 Ceiling areas of 1000 ft292.9 m2 or less
7、 shall beexempt from the lateral force bracing requirements of 5.2.8.1.6 Ceilings constructed of gypsum board which is screw ornail attached to suspended members that support a ceiling onone level extending from wall to wall shall be exempt from thelateral force bracing requirements of 5.2.8.1.7 Fre
8、e floating ceilings (those not attached directly to anystructural walls) supported by chains or cables from thestructure are not required to satisfy the seismic force require-ments provided they meet the following requirements:1.7.1 The design load for such items shall equal 1.4 timesthe vertical op
9、erating weight.1.7.2 Seismic interaction effects shall be considered inaccordance with 5.7.1.7.3 The connection to the structure shall allow a 360range of motion in the horizontal plane.1.8 The values stated in either inch-pound or SI units are tobe regarded as standard. Within the text, the SI unit
10、s are shownin brackets. The values stated in each system are not exactequivalents; therefore, each system shall be used independentlyof the other. Combining values from the two systems result innonconformance with the specification.1.9 This standard does not purport to address all of thesafety conce
11、rns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 635 Specification for the Manufacture,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便