ASTM E557-2012 red 1218 Standard Guide for Architectural Design and Installation Practices for Sound Isolation between Spaces Separated by Operable Partitions 《由活动间壁隔开空间间隔声建筑设计和安装规.pdf
《ASTM E557-2012 red 1218 Standard Guide for Architectural Design and Installation Practices for Sound Isolation between Spaces Separated by Operable Partitions 《由活动间壁隔开空间间隔声建筑设计和安装规.pdf》由会员分享,可在线阅读,更多相关《ASTM E557-2012 red 1218 Standard Guide for Architectural Design and Installation Practices for Sound Isolation between Spaces Separated by Operable Partitions 《由活动间壁隔开空间间隔声建筑设计和安装规.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation:E55700(Reapproved 2006)1Designation: E557 12Standard Guide forThe Installation of Operable PartitionsArchitectural Designand Installation Practices for Sound Isolation betweenSpaces Separated by Operable Partitions1This standard is issued under the fixed designation E557; the number imme
2、diately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard ha
3、s been approved for use by agencies of the Department of Defense.1NOTE1.3, units of measure statement, was editorially inserted and Fig. 3 and 5.3.3 and 5.4 were editorially revised in May2010.1. Scope1.1This guide describes options of intructions recommended to be considered in preparation for, and
4、 application and installationof, operable partitions and, to some extent, in the design of the building in which they are installed. Operable partitions are thosethat are quickly movable.1.1 This guide provides design details that should be considered in the design of buildings that include operable
5、 partitions.Operable partitions are those that can be quickly put in place or removed and stored to provide flexibility in the size of spacestypically used for meetings or social functions.1.1.1 The guide primarily discusses details in the building design required to limit leakage of sound around an
6、 operablepartition.1.1.2 The guide also discusses some factors that affect the performance of the partitions themselves.1.1.3 This guide is neither a specification for operable partitions nor a document intended to be imposed as a requirement onmanufacturers of operable partitions.1.2 Excluded from
7、this guide are those partitions that are classified by the building products industry as demountable.Demountable partitions are those that are designed and installed with the intent of later being taken down and re-erected by a crewover a period of time, with the components being reusable.1.3The1.3
8、The values stated in inch-pound units are to be regarded as standard. The values given in parentheses aremathematical conversions to SI units that are provided for information only and are not considered standard.1.4 This standard does not purport to address all of the safety problems, if any, assoc
9、iated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E90 Test Method for Laboratory Measurement of Airborne Sound
10、Transmission Loss of Building Partitions and ElementsE336 Test Method for Measurement of Airborne Sound Attenuation between Rooms in BuildingsE413 Classification for Rating Sound Insulation E497Practice for Installing Sound-Isolating Lightweight PartitionsE1155 Test Method for Determining FFFloor Fl
11、atness and FLFloor Levelness NumbersE1155M Test Method for Determining FFFloor Flatness and FLFloor Levelness Numbers (Metric)3. Significance and Use3.1 Rooms formed by operable partitions must often need to be isolated acoustically. Sound-isolating properties of operablepartitions are specified by
12、architects in terms of sound transmission class (STC) and so advertised by the manufacturer on the basis1This guide is under the jurisdiction of ASTM Committee E33 on Building and Environmental Acoustics and is the direct responsibility of Subcommittee E33.04 onApplication of Acoustical Materials an
13、d Systems.Current edition approved Sept. 1, 2006. Published September 2006. Originally approved in 1975. Last previous edition approved in 2000 as E557-00. DOI:10.1520/E0557-00R06E01.Current edition approved April 1, 2012. Published June 2012. Originally approved in 1975. Last previous edition appro
14、ved in 2006 as E557 - 00(2006)1. DOI:10.1520/E0557-12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.1This
15、 document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior edition
16、s as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.of laboratory tests in accordance with Test Method E
17、90 and Classification E413.3.2 Because normal building design and construction practices are not the same as those used in acoustical laboratories, actualfield performance of partitions, including operable partitions, will probably be less than that of test specimens. Sound transmissionbetween areas
18、 to be isolated will occur through all of the connecting building components in addition to the operable partition, thatis, floor and ceiling slabs, ceiling plenums, common walls, etc. All possible paths between the areas being isolated should havea sound insulation performance at least equal to the
19、 operable partition. Unless good acoustical practice is followed in both buildingdesign and installation, there may be a significant discrepancy between the sound isolation expected and that achieved.3.3 Because of the complex nature of the sound flanking paths adjacent to operable partitions, it is
20、 highly recommended thatall related construction details be reviewed by a person qualified in acoustical design and construction.3.4 This guide does not specify requirements. However, persons desiring to write installation and construction specificationsmay find the contents useful in developing req
21、uirements for the building design site preparation, and installation practicesnecessary to minimize leakage and flanking sound around the operable partition.4. Properties of Operable Partitions4.1 There are several types of operable partitions: hinged panel groups, individual panel and continuously
22、hinged partitionsystems. Some are supported by overhead track with or without a floor guide or track. Some are floor supported with an overheadtrack to guide them. They may be manual or power-operated. One type consists of movable panels secured in place by verticalexpansion to seal against the floo
23、r and ceiling.4.2 Several factors should be considered in specifications:4.2.1 Seals or gaskets are of many kinds; some consist of resilient material that maintains continuous flexible contact with flooror ceiling, and some include a mechanical, hydraulic or pneumatic mechanism that maintains cleara
24、nce when in motion and apositive seal when finally closed. 4.2Sound Leaks:4.2.1TheThe seals at the top of the partitions should make continuous contact with smooth surfaces on both sides of the operablepartitions. The sound path through an insufficient seal, up and over the track, and out on the oth
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME5572012RED1218STANDARDGUIDEFORARCHITECTURALDESIGNANDINSTALLATIONPRACTICESFORSOUNDISOLATIONBETWEENSPACESSEPARATEDBYOPERABLEPARTITIONS

链接地址:http://www.mydoc123.com/p-533029.html