ASTM E547-2000(2016) 1442 Standard Test Method for Water Penetration of Exterior Windows Skylights Doors and Curtain Walls by Cyclic Static Air Pressure Difference《采用循环静态空气压差法测定外窗 .pdf
《ASTM E547-2000(2016) 1442 Standard Test Method for Water Penetration of Exterior Windows Skylights Doors and Curtain Walls by Cyclic Static Air Pressure Difference《采用循环静态空气压差法测定外窗 .pdf》由会员分享,可在线阅读,更多相关《ASTM E547-2000(2016) 1442 Standard Test Method for Water Penetration of Exterior Windows Skylights Doors and Curtain Walls by Cyclic Static Air Pressure Difference《采用循环静态空气压差法测定外窗 .pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E547 00 (Reapproved 2016)Standard Test Method forWater Penetration of Exterior Windows, Skylights, Doors,and Curtain Walls by Cyclic Static Air Pressure Difference1This standard is issued under the fixed designation E547; the number immediately following the designation indicates the ye
2、ar oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the resis
3、-tance of exterior windows, curtain walls, skylights, and doorsto water penetration when water is applied to the outdoor faceand exposed edges simultaneously with a cyclic static airpressure at the outdoor face higher than the pressure at theindoor face.1.2 This test method is applicable to any curt
4、ain-wall area orto windows, skylights, or doors alone.1.3 This test method addresses water penetration through amanufactured assembly. Water that penetrates the assembly,but does not result in a failure as defined herein, may haveadverse effects on the performance of contained materials suchas seala
5、nts and insulating or laminated glass. This test methoddoes not address these issues.1.4 The proper use of this test method requires a knowledgeof the principles of pressure measurement.1.5 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are mathemati
6、calconversions to inch-pound units that are provided for informa-tion only and are not considered standard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety a
7、nd health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements, see 7.1.2. Referenced Documents2.1 ASTM Standards:2E631 Terminology of Building Constructions3. Terminology3.1 DefinitionsFor definitions of general terms relating tobuilding c
8、onstruction used in this test method, see TerminologyE631.3.2 Definitions of Terms Specific to This Standard:3.2.1 specimen, nthe entire assembled unit submitted fortest as described in Section 8.3.2.2 test pressure difference, nthe specified difference instatic air pressure across the closed and lo
9、cked or fixedspecimen expressed as Pascals (lbf/ft2).3.2.3 water penetration, npenetration of water beyond aplane parallel to the glazing (the vertical plane) intersecting theinnermost projection of the test specimen, not includinginterior trim and hardware, under the specified conditions of airpres
10、sure difference across the specimen. For products withnon-planer glazing surfaces (domes, vaults, pyramids, etc.), theplane defining water penetration is the plane defined by theinnermost edges of the unit frame.4. Summary of Test Method4.1 This test method consists of sealing the test specimeninto
11、or against one face of a test chamber, and supplying air toor exhausting air from the chamber at the rate required tomaintain the test pressure difference across the specimen forthe time cycle specified, while spraying water onto the outdoorface of the specimen at the required rate and observing any
12、water penetration.5. Significance and Use5.1 This test method is a standard procedure for determiningthe resistance to water penetration under cyclic static airpressure differences. The air-pressure differences acting acrossa building envelope vary greatly. These factors should be fullyconsidered pr
13、ior to specifying the test pressure difference to beused.NOTE 1In applying the results of tests by this test method, note thatthe performance of a wall or its components, or both, may be a functionof proper installation and adjustment. In service, the performance will alsodepend on the rigidity of s
14、upporting construction and on the resistance ofcomponents to deterioration by various causes, vibration, thermal expan-sion and contraction, etc. It is difficult to simulate the identical complex1This test method is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the d
15、irect responsibility of Subcommittee E06.51on Performance of Windows, Doors, Skylights and Curtain Walls.Current edition approved Aug. 1, 2016. Published August 2016. Originallyapproved in 1975. Last previous edition approved in 2009 as E547 00(2009). DOI:10.1520/E0547-00R16.2For referenced ASTM sta
16、ndards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken,
17、PA 19428-2959. United States1wetting conditions that can be encountered in service, with large wind-blown water drops, increasing water drop impact pressures with increas-ing wind velocity, and lateral or upward moving air and water. Somedesigns are more sensitive than others to this upward moving w
18、ater.NOTE 2This test method does not identify unobservable liquid waterwhich may penetrate into the test specimen.6. Apparatus6.1 The description of apparatus in this section is general innature, and any arrangement of equipment capable of perform-ing the test procedure within the allowable toleranc
19、es ispermitted.6.2 Major Components (Fig. 1):6.2.1 Test Chamber or box with an opening, a removablemounting panel, or one open side in which or against which thespecimen is installed and sealed.At least one static pressure tapshall be provided to measure the chamber pressure, and shallbe so located
20、that the reading is unaffected by the velocity ofthe air supply to or from the chamber. The air supply openinginto the chamber shall be arranged so that the air does notimpinge directly on the test specimen with any significantvelocity. A means of access into the chamber may be providedto facilitate
21、 adjustments and observations after the specimenhas been installed.6.2.2 Air SystemA controllable blower, compressed airsupply, exhaust system, or reversible blower designed toprovide the required maximum air-pressure difference acrossthe specimen. The system must provide essentially constant airflo
22、w at a fixed pressure for the required test period.6.2.3 Pressure-Measuring ApparatusA device to measurethe test pressure difference within a tolerance of 62% or62.5 Pa (60.01 in. of water column), whichever is greater.6.2.4 Water-Spray System:6.2.4.1 The water-spray system shall deliver water uni-f
23、ormly against the exterior surface of the test specimen at aminimum rate of 3.4 L m2 min (5.0 U.S. gal ft2 h).6.2.4.2 The water-spray system shall have nozzles spacedon a uniform grid, located at a uniform distance from the testspecimen, and shall be adjustable to provide the specifiedquantity of wa
24、ter in such a manner as to wet all of the testspecimen uniformly and to wet those areas vulnerable to waterNOTE 1For a negative pressure system, the water-spray grid would be located outside the chamber and the air supply would be replaced by anair-exhaust system.FIG. 1 General Arrangement of the Wa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME547200020161442STANDARDTESTMETHODFORWATERPENETRATIONOFEXTERIORWINDOWSSKYLIGHTSDOORSANDCURTAINWALLSBYCYCLICSTATICAIRPRESSUREDIFFERENCE

链接地址:http://www.mydoc123.com/p-533016.html