ASTM E502-2007e1 837 Standard Test Method for Selection and Use of ASTM Standards for the Determination of Flash Point of Chemicals by Closed Cup Methods《用密闭杯法确定化学药品闪点的ASTM标准的选择和使用.pdf
《ASTM E502-2007e1 837 Standard Test Method for Selection and Use of ASTM Standards for the Determination of Flash Point of Chemicals by Closed Cup Methods《用密闭杯法确定化学药品闪点的ASTM标准的选择和使用.pdf》由会员分享,可在线阅读,更多相关《ASTM E502-2007e1 837 Standard Test Method for Selection and Use of ASTM Standards for the Determination of Flash Point of Chemicals by Closed Cup Methods《用密闭杯法确定化学药品闪点的ASTM标准的选择和使用.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 502 07e1Standard Test Method forSelection and Use of ASTM Standards for the Determinationof Flash Point of Chemicals by Closed Cup Methods1This standard is issued under the fixed designation E 502; the number immediately following the designation indicates the year oforiginal adoption
2、 or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEMercury warning editorially added in March 2008.1. Scope1.1 This test method cove
3、rs the determination of the flashpoint of liquid and solid chemical compounds flashing frombelow 10 to 370C (16 to 700F). The procedures andapparatus in Test Methods D 56, D 93, D 3278, D 3828, andD 3941 are to be used. Modification to these procedures arespecified for tests on solids and viscous li
4、quids. The signifi-cance of the results obtained is discussed along with possiblesources of error and factors that might cause interference.1.2 Suggestions for adapting this procedure to mixtures ofchemicals are included (see Appendix X2).1.3 This test method should be used to measure and describeth
5、e properties of materials, products, or assemblies in responseto heat and flame under controlled laboratory conditions andshould not be used to describe or appraise the fire hazard or firerisk of materials or assemblies under actual fire conditions.However, results of this test method may be used as
6、 elementsof a fire risk assessment that take into account all of the factorsthat are pertinent to an assessment of the fire hazard of aparticular end use.1.4 WARNING Mercury has been designated by EPAandmany state agencies as a hazardous material that can causecentral nervous system, kidney and live
7、r damage. Mercury, orits vapor, may be hazardous to health and corrosive tomaterials. Caution should be taken when handling mercury andmercury containing products. See the applicable product Ma-terial Safety Data Sheet (MSDS) for details and EPAs website http:/www.epa.gov/mercury/faq.htm - for addit
8、ional infor-mation. Users should be aware that selling mercury and/ormercury containing products into your state may be prohibitedby state law.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standar
9、d to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. See also Section 8.2. Referenced Documents2.1 ASTM Standards:2D56 Test Method for Flash Point by Tag Closed Cup TesterD92 Test Method for Flash and Fire Points by Clevelan
10、dOpen Cup TesterD93 Test Methods for Flash Point by Pensky-MartensClosed Cup TesterD 270 Method of Sampling Petroleum and Petroleum Prod-ucts3D 1310 Test Method for Flash Point and Fire Point ofLiquids by Tag Open-Cup ApparatusD 3278 Test Methods for Flash Point of Liquids by SmallScale Closed-Cup A
11、pparatusD 3827 Test Method for Estimation of Solubility of Gasesin Petroleum and Other Organic LiquidsD 3828 Test Methods for Flash Point by Small Scale ClosedCup TesterD 3934 Test Method for Flash/No Flash TestEquilibriumMethod by a Closed-Cup ApparatusD 3941 Test Method for Flash Point by the Equi
12、libriumMethod With a Closed-Cup ApparatusE 681 Test Method for Concentration Limits of Flammabil-ity of Chemicals (Vapors and Gases)E 1232 Test Method for Temperature Limit of Flammabilityof Chemicals3. Terminology3.1 Definition:3.1.1 flash pointthe lowest temperature, corrected to apressure of 760
13、mm Hg (101.3 kPa) (1013 mbar) at which1This test method is under jurisdiction of ASTM Committee E27 on HazardPotential of Chemicals and is the direct responsibility of Subcommittee E27.04 onFlammability and Ignitability of Chemicals.Current edition approved Jan. 15, 2007. Published March 2007. Origi
14、nallyapproved in 1984. Last previous edition approved in 2006 as E 50206a.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe
15、ASTM website.3Withdrawn.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.application of an ignition source causes the vapors of aspecimen to ignite under specified conditions of test.4. Summary of Test Method4.1 The specimen is placed
16、 in a closed cup and in the smallscale method equilibrated at a test temperature, in the Pensky-Martens Method heated at a controlled rate with stirring, and inthe Tag Method also heated at a controlled rate but withoutstirring. A small flame is directed into the vapor space of eachcup at specified
17、intervals, with simultaneous interruption ofstirring in the Pensky-Martens Method, to determine whether aflash occurs or not. In Test Method D 3941, the specimen isheated at a slower rate than in the other controlled heatingmethods, maintaining a small temperature differential betweenbath and specim
18、en.5. Significance and Use5.1 The flash point measures the response of the sample toheat and flame under controlled laboratory conditions. It isonly one of a number of properties that must be considered inassessing the overall flammability hazard of a material.5.2 As a result of physical factors inh
19、erent in the apparatusand procedure, the closed cup flash point does not necessarilyrepresent the minimum temperature at which a material canevolve flammable vapors, and the absence of a flash point doesnot guarantee nonflammability (see Appendix X1 and Appen-dix X2).5.3 Flash point is used in shipp
20、ing and safety regulations todefine flammable and combustible materials. Test MethodsD 56, D 93, and D 3278 are specified as test methods fordetermining the flash point of these materials.5.4 If the process or handling conditions dictate the usage ofa flammable material at temperatures ranging upwar
21、d from 5 to10C below the closed-cup flash point, then a flammable vapormight be present above the liquid. In such cases, it may bemore appropriate to use the temperature limit of flammability(as determined by Test Method E 1232) instead of flash point.5.5 Small scale methods involving equilibrium pr
22、oceduresand only one flame pass per specimen are preferred.6. Interferences6.1 Incorrect flash points can be obtained when testingchemicals corrosive to the materials of construction of the cup.(For example, certain amines and acid chlorides react with thestandard aluminum small scale cup causing er
23、roneously lowflash points, perhaps due to hydrogen formation.) Cups em-ploying alternative materials of construction, electroplating orplastic coating can provide corrosion resistance. Results innon-standard cups, particularly in non-equilibrium tests, maydiffer slightly from those obtained in this
24、test method.7. Apparatus7.1 Tag Closed-Cup Tester, including thermometers, shallbe as shown in Test Methods D 56 and D 3941.7.2 Penksy-Martens Closed-Cup Tester, including ther-mometers, shall be as shown in Test Methods D93.7.3 Small scale Closed Tester, including thermometers, shallbe as shown in
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME5022007E1837STANDARDTESTMETHODFORSELECTIONANDUSEOFASTMSTANDARDSFORTHEDETERMINATIONOFFLASHPOINTOFCHEMICALSBYCLOSEDCUPMETHODS

链接地址:http://www.mydoc123.com/p-532900.html