《ASTM E499 E499M-2011 2500 Standard Practice for Leaks Using the Mass Spectrometer Leak Detector in the Detector Probe Mode 《在检测器探针法 中用质谱仪检漏器作泄漏检验的标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E499 E499M-2011 2500 Standard Practice for Leaks Using the Mass Spectrometer Leak Detector in the Detector Probe Mode 《在检测器探针法 中用质谱仪检漏器作泄漏检验的标准操作规程》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E499/E499M 11Standard Practice forLeaks Using the Mass Spectrometer Leak Detector in theDetector Probe Mode1, 2This standard is issued under the fixed designation E499/E499M; the number immediately following the designation indicates the yearof original adoption or, in the case of revis
2、ion, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.This specification has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This practice
3、covers procedures for testing and locatingthe sources of gas leaking at the rate of 1 3 107Pa m3/s(1 3 108Std cm3/s)3or greater. The test may be conducted onany device or component across which a pressure differentialof helium or other suitable tracer gas may be created, and onwhich the effluent sid
4、e of the leak to be tested is accessible forprobing with the mass spectrometer sampling probe.1.2 Two test methods are described:1.2.1 Test Method ADirect probing, and1.2.2 Test Method BAccumulation.1.3 UnitsThe values stated in either SI or std-cc/sec unitsare to be regarded separately as standard.
5、 The values stated ineach system may not be exact equivalents: therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.4 This standard does not purport to address all of thesafety concerns, if any, associat
6、ed with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:4E1316 Terminology for Nondestructive Examinations2.2 Other Do
7、cuments:SNT-TC-1A Recommended Practice for Personnel Qualifi-cation and Certification in Nondestructive Testing5ANSI/ASNT CP-189 ASNT Standard for Qualification andCertification of Nondestructive Testing Personnel53. Terminology3.1 DefinitionsFor definitions of terms used in this stan-dard, see Term
8、inology E1316, Section E.4. Summary of Practice4.1 Section 1.8 of the Leakage Testing Handbook6will be ofvalue to some users in determining which leak test method touse.4.2 The test methods covered in this practice require a leakdetector with a full-scale readout of at least 1 3 106Pa m3/s(1 3 107St
9、d cm3/s)3on the most sensitive range, a maximum1-min drift of zero and sensitivity of 65 % of full scale on thisrange, and 62 % or less on others (see 7.1). The abovesensitivities are those obtained by probing an actual standardleak in atmosphere with the detector, or sampling, probe, andnot the sen
10、sitivity of the detector to a standard leak attacheddirectly to the vacuum system.4.3 Test Method A, Direct Probing (see Fig. 1), is thesimplest test, and may be used in parts of any size, requiringonly that a tracer gas pressure be created across the area to betested, and the searching of the atmos
11、pheric side of the area bewith the detector probe. This test method detects leakage andits source or sources. Experience has shown that leak testingdown to 1 3 105Pa m3/s (1 3 106Std cm3/s)3in factoryenvironments will usually be satisfactory if reasonable precau-tions against releasing gas like the
12、tracer gas in the test area areobserved, and the effects of other interferences (Section 6) areconsidered.4.4 Test Method B, Accumulation Testing (see Fig. 2),provides for the testing of parts up to several cubic metres in1This practice is under the jurisdiction of ASTM Committee E07 on Nonde-struct
13、ive Testing and is the direct responsibility of Subcommittee E07.08 on LeakTesting Method.Current edition approved July 1, 2011. Published July 2011. Originally approvedin 1973. Last previous edition approved in 2006 as E499 - 95(2006). DOI:10.1520/E0499_E0499M-11.2(Atmospheric pressure external, pr
14、essure above atmospheric internal). Thisdocument covers the Detector Probe Mode described in Guide E432.3The gas temperature is referenced to 0C. To convert to another gas referencetemperature, Tref, multiply the leak rate by (Tref+ 273)/273.4For referenced ASTM standards, visit the ASTM website, ww
15、w.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.5Available fromAmerican Society for Nondestructive Testing (ASNT), P.O. Box28518, 1711 Arlingate Ln., Columbus, OH 4322
16、8-0518, http:/www.asnt.org.6Marr, J. William, “Leakage Testing Handbook,” prepared for Liquid PropulsionSection, Jet Propulsion Laboratory, NationalAeronautics and SpaceAdministration,Pasadena, CA, Contract NAS 7-396, June 1961.1*A Summary of Changes section appears at the end of this standard.Copyr
17、ight ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.volume as in Fig. 2(a) or in portions of larger devices as in Fig.2(b). This is accomplished by allowing the leakage to accu-mulate in the chamber for a fixed period, while keeping it wellmix
18、ed with a fan, and then testing the internal atmosphere foran increase in tracer gas content with the detector probe. Thepractical sensitivity attainable with this method depends pri-marily on two things: first, on the volume between the chamberand the object; and second, on the amount of outgassing
19、 ofFIG. 1 Method AFIG. 2 Method BE499/E499M 112tracer gas produced by the object. Thus, a part having consid-erable exposed rubber, plastic, blind cavities or threads cannotbe tested with the sensitivity of a smooth metallic part. Thetime in which a leak can be detected is directly proportional toth
20、e leak rate and inversely proportional to the volume betweenthe chamber and the part. In theory, extremely small leaks canbe detected by this test method; however, the time required andthe effects of other interferences limit the practical sensitivityof this test method to about 1 3 107Pa m3/s (1 3
21、108Stdcm3/s)3for small parts.5. Personnel Qualification5.1 It is recommended that personnel performing leak test-ing attend a dedicated training course on the subject and passa written examination. The training course should be appropri-ate for NDT level II qualification according to RecommendedPrac
22、tice No. SNT-TC-1A of the American Society for Nonde-structive Testing or ANSI/ASNT Standard CP-189.6. Significance and Use6.1 Test Method A is frequently used to test large systemsand complex piping installations that can be filled with a tracegas. Helium is normally used. The test method is used t
23、o locateleaks but cannot be used to quantify except for approximation.Care must be taken to provide sufficient ventilation to preventincreasing the helium background at the test site. Results arelimited by the helium background and the percentage of theleaking trace gas captured by the probe.6.2 Tes
24、t Method B is used to increase the concentration oftrace gas coming through the leak by capturing it within anenclosure until the signal above the helium background can bedetected. By introducing a calibrated leak into the samevolume for a recorded time interval, leak rates can be mea-sured.7. Inter
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME499E499M20112500STANDARDPRACTICEFORLEAKSUSINGTHEMASSSPECTROMETERLEAKDETECTORINTHEDETECTORPROBEMODE

链接地址:http://www.mydoc123.com/p-532892.html