ASTM E498 E498M-2011 0625 Standard Practice for Leaks Using the Mass Spectrometer Leak Detector or Residual Gas Analyzer in the Tracer Probe Mode 《在示踪探针法 中用质谱仪检漏器或残余气体分析器作泄漏检验的标准操作.pdf
《ASTM E498 E498M-2011 0625 Standard Practice for Leaks Using the Mass Spectrometer Leak Detector or Residual Gas Analyzer in the Tracer Probe Mode 《在示踪探针法 中用质谱仪检漏器或残余气体分析器作泄漏检验的标准操作.pdf》由会员分享,可在线阅读,更多相关《ASTM E498 E498M-2011 0625 Standard Practice for Leaks Using the Mass Spectrometer Leak Detector or Residual Gas Analyzer in the Tracer Probe Mode 《在示踪探针法 中用质谱仪检漏器或残余气体分析器作泄漏检验的标准操作.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E498/E498M 11Standard Practice forLeaks Using the Mass Spectrometer Leak Detector orResidual Gas Analyzer in the Tracer Probe Mode1, 2This standard is issued under the fixed designation E498/E498M; the number immediately following the designation indicates the yearof original adoption o
2、r, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.This practice has been approved for use by agencies of the Department of Defense.1. Scope*
3、1.1 This practice covers procedures for testing and locatingthe sources of gas leaking at the rate of 1 3 108Pa m3/s(1 3 109Std cm3/s)3or greater.The test may be conducted onany object to be tested that can be evacuated and to the otherside of which helium or other tracer gas may be applied.1.2 Thre
4、e test methods are described:1.2.1 Test Method AFor the object under test capable ofbeing evacuated, but having no inherent pumping capability.1.2.2 Test Method BFor the object under test with integralpumping capability.1.2.3 Test Method CFor the object under test as in TestMethod B, in which the va
5、cuum pumps of the object under testreplace those normally used in the leak detector.1.3 UnitsThe values stated in either SI or std-cc/sec unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents: therefore, eachsystem shall be used independently of
6、 the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health p
7、ractices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:4E1316 Terminology for Nondestructive Examinations2.2 Other Documents:SNT-TC-1A Recommended Practice for Personnel Qualifi-cation and Certification in Nondestructive Testing5ANS
8、I/ASNT CP-189 ASNT Standard for Qualification andCertification of Nondestructive Testing Personnel53. Terminology3.1 DefinitionsFor definitions of terms used in this prac-tice, see Terminology E1316, Section E.4. Summary of Practice4.1 The tests in this practice require a helium leak detectorthat is
9、 capable of detecting a leak of 1 3 109Pa m3/s(1 3 1010Std cm3/s).34.2 Test Method AThis test method is used to helium leaktest objects that are capable of being evacuated to a reasonabletest pressure by the leak detector pumps in an acceptable lengthof time. This requires that the object be clean a
10、nd dry. Also tocope with larger volumes or relatively “dirty” devices, auxil-iary vacuum pumps having greater capacity than those in themass spectrometer leak detector (MSLD) may be used inconjunction with the MSLD. The leak test sensitivity will bereduced under these conditions.4.3 Test Method BThi
11、s test method is used to leak testequipment that can provide its own vacuum (that is, equipmentthat has a built-in pumping system) at least to a level of a fewhundred pascals (a few torr) or lower.4.4 Test Method CWhen a vacuum system is capable ofproducing internal pressures of less than 2 3 102Pa(
12、2 3 104torr) in the presence of leaks, these leaks may belocated and evaluated by the use of either a residual gasanalyzer (RGA) or by using the spectrometer tube and controlsfrom a conventional MSLD, provided, of course, that theleakage is within the sensitivity range of the RGA or MSLDunder the co
13、nditions existing in the vacuum system.1This practice is under the jurisdiction of ASTM Committee E07 on Nonde-structive Testing and is the direct responsibility of Subcommittee E07.08 on LeakTesting Method.Current edition approved July 1, 2011. Published July 2011. Originally approvedin 1973. Last
14、previous edition approved in 2006 as E498 - 95 (2006). DOI:10.1520/E0498_E0498M-11.2(Atmospheric pressure external, vacuum internal). This document covers theTracer Probe Mode described in Terminology E1316.3The gas temperature is referenced to 0C. To convert to another gas referencetemperature, Tre
15、f, multiply the leak rate by (Tref+ 273)/273.4For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.5Available fromA
16、merican Society for NondestructiveTesting (ASNT), P.O. Box28518, 1711 Arlingate Ln., Columbus, OH 43228-0518, http:/www.asnt.org.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, Unit
17、ed States.5. Personnel Qualification5.1 It is recommended that personnel performing leak test-ing attend a dedicated training course on the subject and passa written examination. The training course should be appropri-ate for NDT level II qualification according to RecommendedPractice No. SNT-TC-1A
18、of the American Society for Nonde-structive Testing or ANSI/ASNT Standard CP-189.6. Significance and Use6.1 Test MethodAis the most frequently used in leak testingcomponents which are structurally capable of being evacuatedto pressures of 0.1 Pa (approximately 103torr). Testing ofsmall components ca
19、n be correlated to calibrated leaks, and theactual leak rate can be measured or acceptance can be based ona maximum allowable leak. For most production needs accep-tance is based on acceptance of parts leaking less than anestablished standard which will ensure safe performance overthe projected life
20、 of the component. Care must be exercised toensure that large systems are calibrated with reference leak ata representative place on the test volume. Leak rates aredetermined by calculating the net gain or loss through a leak inthe test part that would cause failure during the expected life ofthe de
21、vice.6.2 Test Method B is used for testing vacuum systems eitheras a step in the final test of a new system or as a maintenancepractice on equipment used for manufacturing, environmentaltest or for conditioning parts. As the volume tends to be large,a check of the response time as well as system sen
22、sitivityshould be made. Volume of the system in liters divided by thespeed of the vacuum pump in L/s will give the response timeto reach 63 % of the total signal. Response times in excess ofa few seconds makes leak detection difficult.6.3 Test Method C is to be used only when there is noconvenient m
23、ethod of connecting the leak detector to the outletof the high vacuum pump. If a helium leak detector is used andthe high vacuum pump is an ion pump or cryopump, leaktesting is best accomplished during the roughing cycle as thesepumps leave a relatively high percentage of helium in the highvacuum ch
24、amber. This will obscure all but large leaks, and thetrace gas will quickly saturate the pumps.7. Interferences7.1 Series leaks with an unpumped volume between thempresent a difficult if not impossible problem in helium leaktesting. Although the trace gas enters the first leak readilyenough since th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME498E498M20110625STANDARDPRACTICEFORLEAKSUSINGTHEMASSSPECTROMETERLEAKDETECTORORRESIDUALGASANALYZERINTHETRACERPROBEMODE

链接地址:http://www.mydoc123.com/p-532889.html