《ASTM E493-2006 Standard Test Methods for Leaks Using the Mass Spectrometer Leak Detector in the Inside-Out Testing Mode《在双面试验模式中用质谱仪检漏器做泄漏检验的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E493-2006 Standard Test Methods for Leaks Using the Mass Spectrometer Leak Detector in the Inside-Out Testing Mode《在双面试验模式中用质谱仪检漏器做泄漏检验的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 493 06Standard Test Methods forLeaks Using the Mass Spectrometer Leak Detector in theInside-Out Testing Mode1This standard is issued under the fixed designation E 493; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods2cover procedures for testing de-vices that are sealed prior to testing, such as semico
3、nductors,hermetically enclosed relays, pyrotechnic devices, etc., forleakage through the walls of the enclosure. They may be usedwith various degrees of sensitivity (depending on the internalvolume, the strength of the enclosure, the time available forpreparation of test, and on the sorption charact
4、eristics of theenclosure material for helium). In general practice the sensi-tivity limits are from 4.4 3 1015to 4.4 3 1011moles/s (109standard cm3/s to 105standard cm3/s at 0C) for helium,although these limits may be exceeded by several decades ineither direction in some circumstances.1.2 Two test
5、methods are described:1.2.1 Test Method ATest part preparation by bombing.1.2.2 Test Method BTest part preparation by prefilling.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish
6、 appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3E 1316 Terminology for Nondestructive Testing2.2 Other Documents:SNT-TC-1A Recommended Practice for Personnel Qualifi-cation and Certification
7、in Nondestructive Testing4ANSI/ASNT CP-189 ASNT Standard for Qualification andCertification of Nondestructive Testing Personnel4MIL-STD-410 Nondestructive Testing Personnel Qualifica-tion and Certification5NAS-410 Certification and Qualification of NondestructiveTest Personnel63. Terminology3.1 Defi
8、nitionsFor definitions of terms used in this stan-dard, see Terminology E 1316, Section E.4. Summary of Test Methods4.1 These test methods require that the test part containhelium at some calculable pressure at the time of test. If thedevice cannot be sealed with a known pressure of heliuminside, it
9、 is necessary to “bomb” the part in a helium pressurechamber in order to introduce helium into the test part if a leakexists.4.2 After the test part has been subjected to helium pressur-izing means, it is placed in an enclosure which is thenevacuated and coupled to a mass spectrometer leak detector.
10、 Inthe event of a leak, an output signal will be obtained from theleak detector. If the actual leak rate of the test part must beknown, this must then be calculated from the output readingand the test parameters.5. Personnel Qualification5.1 If specified in the contractual agreement, personnelperfor
11、ming examinations to these test methods shall be quali-fied in accordance with a nationally-recognized NDTpersonnelqualification practice or standard, such as ANSI/ASNT CP-189, SNT-TC-1A, MIL-STD-410, NAS-410, or a similardocument and certified by the employer or certifying agency,as applicable. The
12、 practice or standard used and its applicablerevision shall be identified in the contractual agreement be-tween the using parties.6. Significance and Use6.1 MethodsAor B are useful in testing hermetically-sealeddevices with internal volumes. Maximum acceptable leak rates1These test methods are under
13、 the jurisdiction of ASTM Committee E07 onNondestructive Testing and are the direct responsibility of Subcommittee E07.08 onLeak Testing Method.Current edition approved Feb. 1, 2006. Published February 2006. Originallyapproved in 1973. Last previous edition approved in 1997 as E 493 - 97.2The inside
14、-out testing mode is characterized by an external vacuum and internalpressure. This standard covers “evacuated,” “sealed with tracer,” and “air-sealed”testing procedures shown in Terminology E 1316.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service
15、at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available fromAmerican Society for NondestructiveTesting (ASNT), P.O. Box28518, 1711 Arlingate Ln., Columbus, OH 43228-0518.5Available from Standardization Docume
16、nts Order Desk, DODSSP, Bldg. 4,Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098.6Available from Aerospace Industries Association of America, Inc. (AIA), 1250Eye St., NW, Washington, DC 20005.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
17、 United States.have been established for microelectronic devices to assureperformance characteristics will not be affected by in-leakageof air, water vapor or other contaminants over the projected lifeexpected. Care must be taken to control the bombing pressure,bombing time and dwell time after bomb
18、ing or the results canvary substantially.7. Interferences7.1 Surface fissures, paint, dirt, polymer seals, etc., can allsorb helium during the bombing procedure and will contributeto the output signal on the leak detector. Unless this process isuniform and consistent, such that nonleaking test parts
19、 alwaysgive the same helium signal, the test sensitivity is limited bythe background signal from sorbed helium. Either one or bothprocedures of nitrogen “washing” or baking parts for 30 minbetween bombing and testing will sometimes help to reducethis background signal.7.2 In the case of large leaks
20、or very small internal volumesin the test parts, the helium presumably sealed or bombed intothe test part may have escaped prior to testing on the massspectrometer leak detector. The test must be made for largeleaks within a few seconds after removing the parts from thebomb or an alternate test meth
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME4932006STANDARDTESTMETHODSFORLEAKSUSINGTHEMASSSPECTROMETERLEAKDETECTORINTHEINSIDEOUTTESTINGMODE

链接地址:http://www.mydoc123.com/p-532881.html