ASTM F331-2013 Standard Test Method for Nonvolatile Residue of Solvent Extract from Aerospace Components (Using Flash Evaporator)《从航空航天部件中提取的卤化溶剂的不挥发残渣的标准试验方法 (使用闪蒸器)》.pdf
《ASTM F331-2013 Standard Test Method for Nonvolatile Residue of Solvent Extract from Aerospace Components (Using Flash Evaporator)《从航空航天部件中提取的卤化溶剂的不挥发残渣的标准试验方法 (使用闪蒸器)》.pdf》由会员分享,可在线阅读,更多相关《ASTM F331-2013 Standard Test Method for Nonvolatile Residue of Solvent Extract from Aerospace Components (Using Flash Evaporator)《从航空航天部件中提取的卤化溶剂的不挥发残渣的标准试验方法 (使用闪蒸器)》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F331 13Standard Test Method forNonvolatile Residue of Solvent Extract from AerospaceComponents (Using Flash Evaporator)1This standard is issued under the fixed designation F331; the number immediately following the designation indicates the year of originaladoption or, in the case of re
2、vision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of nonvolatilematter, that is, residue on evaporation, i
3、n solvent extract fromaerospace components, using a rotary flash evaporator.1.2 The procedure for extraction from components is de-scribed in practices such as Practice F303. Before subjectingthe extract to the following method, it should be processed toremove the insoluble particulate in accordance
4、 with PracticeF311 (Note 1). Particle count analysis of the removed particu-late may then be performed in accordance with Test MethodF312. If particulate is not removed from the extract prior toperforming this method, this should be noted on the test report.NOTE 1Membrane filters with a maximum extr
5、actable content of 0.5weight % should be used on samples to be processed by this test method.Conventional membranes contain 5 to 10 % extractables. For obtainingvery low background levels, consideration should be given to usingmembranes without grid marks.1.3 The values stated in SI units are to be
6、regarded asstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to
7、 use.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterF303 Practices for Sampling for Particles in AerospaceFluids and ComponentsF311 Practice for Processing Aerospace Liquid Samples forParticulate Contamination Analysis Using Membrane Fil-tersF312 Test Methods for Mic
8、roscopical Sizing and CountingParticles from Aerospace Fluids on Membrane Filters2.2 IEST Standard:3IEST-STD-1246D Product Cleanliness Levels and Contami-nation Control Program3. Summary of Test Method3.1 A sample of fluid or the filtrate (Note 1) from a sampleof extract from components is evaporate
9、d as necessary toapproximately 20 mL in a flash evaporator. The residue is thentransferred to a foil dish and the evaporation completed byheating to a constant weight.4. Apparatus4.1 Oven, gravity convection provided with suitable ther-mometer and a temperature range suitable for the solvent beingev
10、aporated.4.2 Analytical Balance, single pan or magnetically dampeddouble pan.NOTE 2Sensitivity shall be suitable to obtain the required precisionnoted in 10.1.4.3 Evaporator, flash, batch-type.4.4 Graduated Cylinder.4.5 Tongs or forceps, laboratory, for manipulating weighingfoil dishes.4.6 Desiccato
11、r, balance, to be placed in balance case.4.7 Desiccator, cooling with plate.4.8 Weighing Vessels, aluminum foil weighing dishes. Thesemay be purchased pre-formed dishes or may be constructedfrom clean aluminum foil.4.9 Pressure Source, capable of providing 85 KPa (25-in.Hg) for short interval.4.10 D
12、istillation Apparatus, laboratory, all glass (requiredwhere solvents with sufficiently low residue are not available).Do not use grease or oil to lubricate glass joints.1This test method is under the jurisdiction of ASTM Committee E21 on SpaceSimulation and Applications of Space Technology and is th
13、e direct responsibility ofSubcommittee E21.05 on Contamination.Current edition approved June 1, 2013. Published July 2013. Originally approvedin 1970. Last previous edition approved in 2005 as F331 05. DOI: 10.1520/F0331-13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcont
14、act ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Standardization Document Order Desk, Bldg. 4 Section D, 700Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.Copyrig
15、ht ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15. Reagents and Materials5.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications
16、 of the Commit-tee on Analytical Reagents of the American Chemical Societywhere such specifications are available.4Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.5.2 Purity
17、of WaterUnless otherwise indicated, referencesto water shall be understood to mean reagent water conformingto Specification D1193.5.3 Solvent for Extracting and RinsingThe baseline NVRof the solvent shall not exceed 10 % of the requirement beingtested.5.4 Cleaning AgentLiquid surface-active agent. A
18、pprovedequivalent may be used, provided they can be adequatelyrinsed from the surface, leaving a negligible residue.5.5 Desiccant, silica gel, indicating.6. Preparation of Apparatus6.1 Wash the inner walls of the evaporator flask andgraduated cylinder thoroughly with a solution of liquid,surface-act
19、ive cleaning agent in hot water and rinse with tapwater (Note 3). Dry thoroughly. Double rinse with test solvent.NOTE 3Distilled or deionized water shall be used in areas in whichhardness or contamination increase the blank over the allowable level.6.2 Soak the weighing vessels in solvent for 1 h. D
20、ry theweighing vessels in the oven at 65C or 3C above theevaporation point of the solvent for 1 h. Place the weighingvessels in the desiccator for 30 min minimum. Do not touchfoil dishes with the fingers. Use laboratory tongs or forceps asapplicable.7. Procedure7.1 Determine sample volume (Note 4) u
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF3312013STANDARDTESTMETHODFORNONVOLATILERESIDUEOFSOLVENTEXTRACTFROMAEROSPACECOMPONENTSUSINGFLASHEVAPORATOR

链接地址:http://www.mydoc123.com/p-532586.html