1、Designation: F309 04 (Reapproved 2018)Standard Practice forLiquid Sampling of Noncryogenic Aerospace Propellants1This standard is issued under the fixed designation F309; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year of
2、last revision. A number in parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers procedures for obtaining a sampleof noncryogenic aerospace propellant. Two procedures arecovered
3、as follows:Procedure 1Closed System (Section 6), andProcedure 2Open-End Procedure (Section 7).1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and e
4、nvironmental practices and deter-mine the applicability of regulatory limitations prior to use.For hazard statements see Sections 4 and 5.1.3 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Princip
5、les for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2F311 Practice for Processing Aerospace Liquid Samples forParticulate Contamination Analysis Usin
6、g Membrane Fil-ters3. Summary of Practice3.1 Samples are withdrawn from the system by (1) a closedvessel capture, and (2) an open-end vessel (see Fig. 1). Bothprocedures are practical for most liquid aerospace propellantsnot excessively corrosive or toxic.4. Apparatus4.1 Stainless Steel Pressure Sam
7、pling Cylinders, 1-Lcapacity, equipped with stainless steel valves on each end.4.1.1 CautionPressure sampling cylinders must bemarked for the liquid being sampled. Cylinders for onematerial must not be interchanged with sampling cylinders ofother materials because of the possibility of incompatibili
8、ty.4.2 Full Protective Suits.4.2.1 CautionDue to the toxic and corrosive nature ofmost propellent fluids and their vapors, extreme care must beexercised in handling. Full protective suits must be worn whensampling these fluids.4.3 Polyethylene Wash Bottle, 1-L capacity, filled withdemineralized wate
9、r, filtered in the manner described in Prac-tice F311.4.4 Stainless Steel Bucket.4.5 Miscellaneous Fittings, as needed for sample pointadaption.5. Hazards5.1 Care should be taken when handling propellants sincemost of them are toxic to some degree. Care should also betaken when sampling fluids from
10、a system under dynamicconditions.PROCEDURE 1CLOSED SYSTEM6. Procedure6.1 Sampling cylinders must be clean, particulate-controlledin accordance with system requirements, and have a partialvacuum of 10 % of atmospheric pressure.6.2 After removing protective caps, connect both ends of thesampling cylin
11、der to the system sampling ports, using fittingsas necessary.6.3 Open both sampling valves and both sampling cylindervalves, and allow fluid to flow through the sampling cylinderfor 10 min.6.4 Close all four valves downstream side first, and removethe sampling cylinder from the system.6.5 Rinse the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF30920042018STANDARDPRACTICEFORLIQUIDSAMPLINGOFNONCRYOGENICAEROSPACEPROPELLANTSPDF

链接地址:http://www.mydoc123.com/p-532555.html