ASTM F139-2003 Standard Specification for Wrought 18 Chromium-14 Nickel-2 5 Molybdenum Stainless Steel Sheet and Strip for Surgical Implants (UNS S31673)《外科植入物用锻造18铬-14镍-2 5钼不锈钢薄板及.pdf
《ASTM F139-2003 Standard Specification for Wrought 18 Chromium-14 Nickel-2 5 Molybdenum Stainless Steel Sheet and Strip for Surgical Implants (UNS S31673)《外科植入物用锻造18铬-14镍-2 5钼不锈钢薄板及.pdf》由会员分享,可在线阅读,更多相关《ASTM F139-2003 Standard Specification for Wrought 18 Chromium-14 Nickel-2 5 Molybdenum Stainless Steel Sheet and Strip for Surgical Implants (UNS S31673)《外科植入物用锻造18铬-14镍-2 5钼不锈钢薄板及.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 139 03Standard Specification forWrought 18Chromium-14Nickel-2.5Molybdenum StainlessSteel Sheet and Strip for Surgical Implants (UNS S31673)1This standard is issued under the fixed designation F 139; the number immediately following the designation indicates the year oforiginal adoptio
2、n or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Sc
3、ope*1.1 This specification covers the requirements for wrought18chromium-14nickel-2.5molybdenum stainless steel sheetand strip used for the manufacture of surgical implants.1.2 The values stated in inch-pound units are to be regardedas the standard.2. Referenced Documents2.1 ASTM Standards:A 262 Pra
4、ctices for Detecting Susceptibility to Intergranu-lar Attack in Austenitic Stainless Steels2A 480/A480M Specification for General Requirements forFlat-Rolled Stainless and Heat-Resisting Steel Plate,Sheet, and Strip2A 751 Test Methods, Practices, and Terminology forChemical Analysis of Steel Product
5、s2E 45 Test Methods for Determining the Inclusion Contentof Steel3E 112 Test Methods for Determining the Average GrainSize3E 407 Practice for Microetching Metals and Alloys3F 981 Practice for Assessment of Compatibility of Bioma-terials for Surgical Implants With Respect to Effect ofMaterials on Mus
6、cle and Bone42.2 ISO Standard:ISO 5832-1 Implants for Surgery-Metallic MaterialsPart1: Wrought Stainless Steel52.3 American Society for Quality (ASQ) Standard:C1 Specification of General Requirements for a QualityProgram63. General Requirements for Delivery3.1 In addition to the requirements of this
7、 specification, allrequirements of the current edition of Specification A 480/A 480M shall apply.3.2 In the case where a conflict exists between this specifi-cation and those listed in 2.1 and 2.2, this specification shalltake precedence.4. Ordering Information4.1 Inquiries and orders for material u
8、nder this specificationshall include the following information:4.1.1 Quantity (weight or number of pieces),4.1.2 ASTM designation,4.1.3 Form (sheet or strip),4.1.4 Condition (see 5.1),4.1.5 Mechanical properties (if applicable, for special con-ditions),4.1.6 Finish (see 5.2),4.1.7 Applicable dimensi
9、ons including size, thickness,width, and length (exact, random, multiples) or print number,and4.1.8 Special requirements.5. Materials and Manufacture5.1 Condition:5.1.1 Sheet and strip shall be furnished as specified, in theannealed or cold-worked condition (see Table 1).5.2 Finish:5.2.1 Types of fi
10、nish available in sheet and strip are dullcold rolled, bright cold rolled, intermediate polished, general-purpose polished, dull satin-finished, high luster finish, mirrorfinish, or as specified in the purchase order.1This specification is under the jurisdiction of ASTM Committee F04 onMedical and S
11、urgical Materials and Devices and is the direct responsibility ofSubcommittee F04.12 on Metallurgical Materials.Current edition approved June 10, 2003. Published July 2003. Originallyapproved 1976. Last previous edition approved in 2000 as F 139 00.2Annual Book of ASTM Standards, Vol 01.03.3Annual B
12、ook of ASTM Standards, Vol 03.01.4Annual Book of ASTM Standards, Vol 13.01.5Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.6Available from American Society for Quality (ASQ), 600 N. Plankinton Ave.,Milwaukee, WI 53203.1*A Summary of Changes
13、section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6. Chemical Composition6.1 The heat analysis shall conform to the requirements asto chemical composition specified in Table 2.6.1.1 The compos
14、itional requirement shall meet the follow-ing:%Cr1 3.3 3 %Mo$ 26.0 (1)6.1.2 Requirements for the major and minor elementalconstituents are listed in Table 2. Also listed are importantresidual elements. Analysis for elements not listed in Table 2 isnot required to certify compliance with this specifi
15、cation.6.2 Product Analysis Product analysis tolerances do notbroaden the specified heat analysis requirements, but covervariations between laboratories in the measurement of chemi-cal content. The manufacturer shall not ship material that isoutside the limits specified in Table 2. Product analysis
16、limitsshall be as specified in Table 3.6.2.1 The product analysis is either for the purpose ofverifying the composition of a heat or lot or to determinevariations in the composition within the heat.6.2.2 Acceptance or rejection of a heat or lot of materialmay be made by the purchaser on the basis of
17、 this checkanalysis.6.3 Methods and practices relating to chemical analysisrequired by this specification shall be in accordance with TestMethods, Practices, and Terminology A 751.7. Metallurgical Requirements7.1 The material shall contain no delta ferrite, chi, or sigmaphases when it is examined me
18、tallographically at 1003 mag-nification in accordance with Practice E 407.7.2 The microcleanliness of the steel as determined by TestMethods E 45, Method A, except using Plate I-r on represen-tative samples from the hot-rolled band from the heat shall notexceed the following:InclusionTypeA(Sulfide)B
19、(Alumina)C(Silicate)D(Globular Oxide)Thin 1.5 1.5 1.5 1.5Heavy 1.5 1.0 1.5 1.08. Mechanical Properties8.1 Material shall conform to the appropriate requirementsas to mechanical properties specified in Table 1. The level ofmechanical properties for material in conditions other thanthose included in T
20、able 1 shall be specified in the purchaseorder.8.2 When desired, Rockwell hardness, A scale (HRA),Rockwell hardness, B scale (HRB) or Rockwell hardness, CScale (HRC), limits may be specified.9. Special Tests9.1 The steel shall be capable of passing the intergranularcorrosion susceptibility test in a
21、ccordance with PracticesA 262, Practice E.9.2 The grain size shall be five or finer when tested inaccordance with Test Methods E 112.9.2.1 It is preferred that samples for grain size determinationbe selected after the final annealing operation and prior to afinal cold-working operation.9.2.2 If samp
22、les are selected after a final cold-workingoperation, specimens shall be tested according to Test MethodE 112, or as agreed to between the supplier and purchaser.9.3 Any other special requirements shall be specified on thepurchase order.10. Certification10.1 The manufacturers certification that the
23、material wasmanufactured and tested in accordance with this specificationtogether with a report of the test results shall be furnished at thetime of shipment.11. Quality Program Requirements11.1 The producer shall maintain a quality program, such asdefined in ASQ C1.11.2 The manufacturer of surgical
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF1392003STANDARDSPECIFICATIONFORWROUGHT18CHROMIUM14NICKEL25MOLYBDENUMSTAINLESSSTEELSHEETANDSTRIPFORSURGICALIMPLANTSUNSS31673

链接地址:http://www.mydoc123.com/p-532437.html