ASTM E3040-2016 Standard Practice for Evaluation of Instrumental Color Difference with a Gray Scale《用灰度标评估仪器色差的标准实施规程》.pdf
《ASTM E3040-2016 Standard Practice for Evaluation of Instrumental Color Difference with a Gray Scale《用灰度标评估仪器色差的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E3040-2016 Standard Practice for Evaluation of Instrumental Color Difference with a Gray Scale《用灰度标评估仪器色差的标准实施规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E3040 16Standard Practice forEvaluation of Instrumental Color Difference with a GrayScale1This standard is issued under the fixed designation E3040; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revi
2、sion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 Test Method D2616 describes a painted gray scale andthe procedure to be used in the visual evaluation of colordifferences on no
3、n-self-luminous materials by comparison tothis scale. This practice provides an alternative method ofobtaining a similarly valued result by an instrumental method.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard, except that
4、the test results of this test method areconverted by the calculations to an arbitrary visual scaledefined by Test Method D2616, whose units are called GSC(Gray Scale for Change in Color).1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is t
5、heresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D2244 Practice for Calculation of Color Tolerances andColor Differences from Instrume
6、ntally Measured ColorCoordinatesD2616 Test Method for Evaluation of Visual Color Differ-ence With a Gray ScaleE284 Terminology of AppearanceE308 Practice for Computing the Colors of Objects by Usingthe CIE SystemE1164 Practice for Obtaining Spectrometric Data for Object-Color Evaluation2.2 ISO Stand
7、ards:3ISO 105-A05 TextilesTests for ColorfastnessPart A05Instrumental assessment of change in colour for determi-nation of grey scale rating2.3 AATCC Standards:4AATCC Evaluation Procedure 7 Instrumental Assessment ofthe Change in Color of a Test Specimen2.4 JIS Standards:5JIS L 0809 Instrumental det
8、ermination of colour fastness Change in colour and staining3. Terminology3.1 Definitions:3.1.1 Definitions of appearance terms in Terminology E284are applicable to this test method.3.2 Definitions of Terms Specific to This Standard:3.2.1 color change, na change in color of any kindwhether in lightne
9、ss, hue, or chroma or any combination ofthese, discernible by comparing the test specimen with acorresponding untested specimen.3.2.2 gray scale grade, GSC, nfor color change, thenumerical value that is assigned to the change in color of a testspecimen as compared to an original or untreated specime
10、n.4. Summary of Test Method4.1 The color of a specimen that has been submitted to a testwhose severity is evaluated by change in color, and an identicaluntreated specimen, are measured spectrophotometrically andboth of their colors evaluated by conventional means. Theconventional color difference at
11、tributes are converted to a GrayScale for Color Change by a series of calculations.4.2 This practice is similar to the following three interna-tional methods: AATCC Evaluation Procedure 7, ISO 105-A05, and JIS L 0809.1This practice is under the jurisdiction of ASTM Committee E12 on Color andAppearan
12、ce and is the direct responsibility of Subcommittee E12.04 on Color andAppearance Analysis.Current edition approved July 1, 2016. Published July 2016. Originally approvedin 2015. Last previous edition approved in 2015 as E3040 15. DOI: 10.1520/E3040-16.2For referenced ASTM standards, visit the ASTM
13、website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036,
14、http:/www.ansi.org.4Available from American Association of Textile Chemists and Colorists(AATCC), P.O. Box 12215, Research Triangle Park, NC 27709-2215, http:/www.aatcc.org.5Available from Japanese Standards Association (JSA), Mita MT Bldg., 3-13-12Mita, Minato-ku, Tokyo 108-0073, Japan, http:/www.j
15、sa.or.jp.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15. Significance and Use5.1 The gray scale grade GSCis useful to evaluate the colordifference of any pair of colors that have been subjected to atest whose severity of result is
16、nominated by color difference ofthe treated member to the untreated member. This includes, butis not limited to, scrub tests, exterior exposures, crocking tests,blocking tests, certain abrasion tests, and color transfer tests.5.2 A major advantage of the instrumental method ofobtaining gray scale gr
17、ades is that under the visual methodsubstantial screening and training of the operators in visualcolor assessment is required. No such burden is placed on theoperators in this instrumental method.5.3 The method is usually not used for staining tests whichhave their own gray scale for staining.6. App
18、aratus6.1 Spectrophotometer, having one of the three qualifiedgeometries that are listed in Practice E1164. These geometriesinclude: bidirectional (more familiarly called 0/45 or 45/0),or hemispherical specular included, or hemispherical specularexcluded geometries.6.2 In the absence of any reason f
19、or choosing one over theother, hemispherical specular included geometry is most ap-propriate for the type of measurements that are made inconnection with this standard.7. Sampling, Test Specimens, and Test Units7.1 The specimen pairs used in this practice are nearlyalways a pair of identical specime
20、ns where one member of thepair has been subjected to a test whose severity of result maybe quantified by a change in color.7.2 The practice is based upon a visual method D2616 ofassessing the degree of this color change. The precision of thevisual method is such that the gray scale grade is reported
21、 tothe nearest half-unit on a scale of five to one. This method isdesigned to emulate the results of Test Method D2616 and assuch is reported in these same half-units.8. Calibration and Standardization8.1 Maintain the spectrophotometer in a state of calibration.Standardize the spectrophotometer in a
22、ccordance with themanufacturers instructions, or follow the standardization prac-tices of Practice E1164.9. Procedure9.1 Measure the color of the reference specimen and calcu-late the CIELAB L*, a*, b*, C* and h values using the data forthe 10 observer and for illuminant D65.9.2 Measure the color of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME30402016STANDARDPRACTICEFOREVALUATIONOFINSTRUMENTALCOLORDIFFERENCEWITHAGRAYSCALE 灰度 评估 仪器 色差 标准

链接地址:http://www.mydoc123.com/p-532277.html