ASTM E2966-2014 Standard Test Method for Quantitative Assessment of Sanitizing Solutions for Carpet《地毯消毒液定量评定的标准试验方法》.pdf
《ASTM E2966-2014 Standard Test Method for Quantitative Assessment of Sanitizing Solutions for Carpet《地毯消毒液定量评定的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2966-2014 Standard Test Method for Quantitative Assessment of Sanitizing Solutions for Carpet《地毯消毒液定量评定的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2966 14Standard Test Method forQuantitative Assessment of Sanitizing Solutions for Carpet1This standard is issued under the fixed designation E2966; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last rev
2、ision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is designed to evaluate quantitativelythe antibacterial and antifungal activity of solutions for sani-tizing
3、carpets.1.2 Efficacy is reported as the log reduction in viablebacteria and fungi.1.3 The bacteria used in the test are Staphylococcus aureus,Enterobacter aerogenes, and Pseudomonas aeruginosa. Themold used is Aspergillus brasiliensis.1.4 Knowledge of microbiological techniques is requiredfor this t
4、est method.1.5 UnitsThe values stated in SI units are to be regardedas standard. No other units of measurement are included in thisstandard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard t
5、o establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E1054 Test Methods for Evaluation of Inactivators of Anti-microbial AgentsE2471 Test Method for Using Seeded-Agar for the Screen-ing
6、 Assessment of Antimicrobial Activity In Carpets3. Terminology3.1 Definitions:3.1.1 carpet cleaner/sanitizer, nsolution that cleans em-bedded soil from the carpet fiber and reduces biocontaminantlevels on carpet when applied at the recommended dilution andcontact time specified on the product label.
7、3.1.2 carpet sanitizer, nchemical solution that reducesbiocontaminant levels on carpet when applied at the recom-mended dilution and contact time specified on the productlabel.3.1.3 sanitizer, nchemical or physical agent(s) used toreduce the number of microorganisms to a level judged to beappropriat
8、e for a defined purpose and/or claim.3.1.3.1 DiscussionThe US EPA regulates sanitizers usedon porous and non-porous surfaces. EPA 810 Guidelinesprovide a description of each category, the required testmethod, test conditions, and performance criteria. EPA810.2400 (f) describes requirements for testi
9、ng carpet sanitiz-ers.33.1.3.2 DiscussionIn the context of this method effectivesanitization reduces the number of microorganisms to levelsconsidered safe as determined by public health codes orregulations.3.1.4 vacuum extraction unit, nmachine for deep cleaningcarpet that delivers a spray of cleani
10、ng solution, provides brushagitation of the pile, and recovers soil and cleaning solutionunder vacuum.4. Summary of Test Method4.1 In this test method, the efficacy of solutions intended tohave a sanitizing effect on carpet are quantitatively evaluated.Carpet sample coupons are cut from a larger fie
11、ld of carpet andre-embedded within the field. The carpet coupons are inocu-lated with microorganisms followed by a drying period. Afterthe inoculum-drying period, the sanitizing solution is appliedto the carpet coupons followed by scrubbing.Additional carpetcoupons are spray treated and scrubbed wit
12、h a inert solution.After the chemical contact period, carpet coupons are asepti-cally removed and placed into neutralizing broth. Each neu-tralizing broth with carpet coupon is placed into a ultrasonicbath for 1 min followed by 1 min of wrist action shaking. Serialdilutions are performed on each sam
13、ple followed by plating(pour or spread plates or other standard for enumerating viablecells). Log reduction of the viable cell counts recovered from“scrubbed-controls” versus viable cell counts recovered fromthe sanitizer-treated carpets are recorded.1This test method is under the jurisdiction of AS
14、TM Committee E35 onPesticides, Antimicrobials, and Alternative Control Agents and is the directresponsibility of Subcommittee E35.15 on Antimicrobial Agents.Current edition approved May 15, 2014. Published June 2014. DOI: 10.1520/E2966142For referenced ASTM standards, visit the ASTM website, www.ast
15、m.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3http:/www.epa.gov/ocspp/pubs/frs/publications/Test_Guidelines/series810.htmCopyright ASTM International, 100 Barr Harbor Dr
16、ive, PO Box C700, West Conshohocken, PA 19428-2959. United States15. Significance and Use5.1 Carpet, when exposed to the environment or foot traffic,accumulates soil and biocontaminants during its in-service life.While routine vacuuming may effectively remove dry particu-late soils, it has a limited
17、 effect on removing or killingaccumulated and embedded biocontaminants. In this testmethod, steps are described to assess test substances for theability to sanitize carpet.5.2 This test method compares an inert control solution to asanitizing test solution for the ability to reduce viable bacteriaan
18、d fungi inoculated onto carpet samples.5.3 This test method provides for efficient recovery ofsurviving bacteria from inoculated carpets.6. Apparatus6.1 For broadloom-type carpets (typically a 3.7-m rollcarpet),a2cmthick plywood cut (40 by 40 cm) with the samedimension tempered hardboard attached is
19、 used to mount thecarpet. Brass brads are used to secure the carpet sample to thetempered hardboard.6.2 For carpet tile with a dimensionally stable backing, nomounting board is required.6.3 Cutting the carpet into samples can be accomplishedwith a traditional carpet knife or the use of mechanical cu
20、ttingdies and a hydraulic press. One mechanical cutting die, 20 cmby 30 cm, and another mechanical cutting die, 5 cm by 5 cm,are used.6.4 One-sided adhesive tabs are used to temporarily securethe precut 5-cm by 5-cm carpet carriers “in plane” with theremaining carpet during the scrubbing procedure.
21、Alternately,the 90 corners of the 20 cm by 30 cm section may be nailed ortacked to the mounting board.6.5 Spray DeviceAspray unit is used to atomize the carpetsanitizer.NOTE 1An atomizer may also be used. Aerosol formulated sprayproducts may be directly sprayed onto the carpet.6.6 Scrub Brushes, sur
22、gical hand brush.6.7 Extraction Bottles, wide-mouth round 500-mL polypro-pylene bottles with screw caps.NOTE 2For the procedure, each bottle will contain 100 mL of sterileneutralizer broth.6.8 Ultrasonic Bath.6.9 Wrist-action-shaker.7. Reagents and Media7.1 Sanitizer Solutions:7.1.1 Test a single lo
23、t of the candidate carpet sanitizer.Consult the appropriate regulatory 101 guidelines for lotreplication requirements for registration purposes (forexample, US EPA 810 102 Guidelines).7.1.2 If the product is to be used as a “One-step cleaner-sanitizer,” a 5% soil load (for example, animal sera) may
24、beadded to the inoculum.7.1.3 Recommended application rates (volume per unit area,that is, ml/m2) are extrapolated and reported from the proposedcarpet application rate to the sample size used for this testmethod.7.2 Carpet Specifications:7.2.1 Two carpet types should be tested. For example, carpetw
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME29662014STANDARDTESTMETHODFORQUANTITATIVEASSESSMENTOFSANITIZINGSOLUTIONSFORCARPET 地毯 消毒液 定量 评定 标准

链接地址:http://www.mydoc123.com/p-532179.html