ASTM E2957-2015 Standard Test Method for Resistance to Wildfire Penetration of Eaves Soffits and Other Projections 《屋檐 拱腹和其他突出物抗大火灾穿透性的标准试验方法》.pdf
《ASTM E2957-2015 Standard Test Method for Resistance to Wildfire Penetration of Eaves Soffits and Other Projections 《屋檐 拱腹和其他突出物抗大火灾穿透性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2957-2015 Standard Test Method for Resistance to Wildfire Penetration of Eaves Soffits and Other Projections 《屋檐 拱腹和其他突出物抗大火灾穿透性的标准试验方法》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2957 15Standard Test Method forResistance to Wildfire Penetration of Eaves, Soffits andOther Projections1This standard is issued under the fixed designation E2957; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the y
2、ear of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This fire-test-response standard prescribes a method forqualitatively assessing the resistance to fire penetrat
3、ion of eaveoverhangs and other projections, such as the soffits of roofeaves and cantilevered floor projections, when exposed todirect flame impingement from a simulated external wildfireexposure, such as encountered in a “Wildland Urban Interface”scenario. This test method provides data suitable fo
4、r comparingthe relative performance of materials, which are used as theexposed underside surfaces of eave overhangs and otherprojections.1.2 This test method measures the ability of eave overhangsand other projections to resist fire penetration from the exteriorinto the wall cavity or unexposed side
5、 of the test specimenunder the conditions of exposure.1.3 This test method is applicable to eave overhangs andother projections such as the soffits of roof eaves and cantile-vered floor projections intended for use with either combustibleor noncombustible building envelopes.1.4 Limitations of the te
6、st method are listed in Section 5.1.5 The values stated in metric units are to be regarded asthe standard. Values in parentheses are for information only.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of t
7、his standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.7 This standard is used to measure and describe theresponse of materials, products, or assemblies to heat andflame under controlled laboratory conditions, but
8、does not byitself incorporate all factors required for fire hazard or fire riskassessment of the materials, products or assemblies underactual fire conditions.1.8 Fire testing is inherently hazardous. Adequate safe-guards for personnel and property shall be employed inconducting these tests.1.9 The
9、text of this standard references notes and footnoteswhich provide explanatory material. These notes and footnotes(including those in tables and figures) shall not be consideredas requirements of the standard.2. Referenced Documents2.1 ASTM Standards:2C1396 Specification for Gypsum BoardD2898 Practic
10、e for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire TestingD4442 Test Methods for Direct Moisture Content Measure-ment of Wood and Wood-Base MaterialsD4444 Test Method for Laboratory Standardization andCalibration of Hand-Held Moisture MetersD6662 Specification for Polyolefin-Based
11、Plastic LumberDecking BoardsD7032 Specification for Establishing Performance Ratingsfor Wood-Plastic Composite Deck Boards and GuardrailSystems (Guards or Handrails)E176 Terminology of Fire StandardsE631 Terminology of Building ConstructionsE2707 Test Method for Determining Fire Penetration ofExteri
12、or Wall Assemblies Using a Direct Flame Impinge-ment ExposureE2912 Test Method for Fire Test of Non-Mechanical FireDampers Used in Vented ConstructionE2886/E2886M Test Method for Evaluating the Ability ofExterior Vents to Resist the Entry of Embers and DirectFlame Impingement2.2 Other Standards:ISO
13、13943 Fire SafetyVocabulary3NFPA 286 Standard Methods of Fire Tests for EvaluatingContribution of Wall and Ceiling Interior Finish to RoomFire Growth41This test method is under the jurisdiction of ASTM Committee E05 on FireStandards and is the direct responsibility of Subcommittee E05.14 on External
14、 FireExposures.Current edition approved July 1, 2015. Published August 2015. DOI: 10.1520/E2957-152For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Docu
15、ment Summary page onthe ASTM website.3Available from International Organization for Standardization (ISO), 1, ch. dela Voie-Creuse, CP 56, CH-1211 Geneva 20, Switzerland, http:/www.iso.org.4Available from National Fire Protection Association (NFPA), 1 BatterymarchPark, Quincy, MA 02169-7471, http:/w
16、ww.nfpa.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13. Terminology3.1 DefinitionsFor definitions of terms used in thisstandard, see Terminology E176, E631 and ISO 13943. In caseof conflict between E176 and E631 or ISO 13943, t
17、hedefinitions given in Terminology E176 shall prevail. In case ofconflict between E631 and ISO 13943, the definitions given inTerminology E631 shall prevail.3.2 Definitions of Terms Specific to This Standard:3.2.1 building envelope, nthe boundary or barrier separat-ing different environmental condit
18、ions within a building andfrom the outside environment.3.2.2 eave, na projecting edge of a roof that extendsbeyond the building envelope.3.2.3 glow, nvisible light emitted by a solid undergoingcombustion.3.2.4 holding fixture, napparatus designed to hold the testspecimen and a wall assembly, describ
19、ed in 7.3.3.2.5 projection, nan exterior outcrop of the building,such as a cantilevered room, that protrudes from or overhangsthe building envelope.3.2.5.1 DiscussionExamples include, but are not limitedto, eaves, soffits, enclosed cantilevered balconies, and enclosedcantilevered room bump-outs.3.2.
20、6 sofft, nthe enclosed underside of any exterior over-hanging section of a roof eave.3.2.7 sustained flaming, nflame on or over the surface ofa test specimen that lasts longer than a period of 4 s.3.2.8 wall assembly, nframed vertical section simulatingan exterior wall below an eave overhang or proj
21、ection used inthe evaluation of test specimen.3.2.8.1 DiscussionParagraph 7.2 describes the wall as-sembly used in this test method.4. Summary of Test Method4.1 This test method provides for the direct flame exposureof eave overhang and other projections.4.2 This test method employs a gas burner to
22、produce adiffusion flame in contact with the test specimen.4.3 The flame source is centered left to right and below thetest specimen.4.4 The gas burner produces a prescribed net rate of heatoutput during the flame exposure period, after which the flameexposure is terminated.4.5 The test method monit
23、ors the fire characteristics and theability of the test specimen to resist fire penetration during theflame exposure period and a subsequent observation period.4.6 Observations are made for the appearance of sustainedflaming and glow on the unexposed side during the 10-minflame exposure period and a
24、 subsequent 30-min observationperiod.5. Significance and Use5.1 The test method described herein monitors the firecharacteristics and the ability of eave overhangs and otherprojections to resist exterior fire penetration from underneathunder the specified fire exposure conditions.5.2 Representative
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME29572015STANDARDTESTMETHODFORRESISTANCETOWILDFIREPENETRATIONOFEAVESSOFFITSANDOTHERPROJECTIONS 屋檐

链接地址:http://www.mydoc123.com/p-532166.html