1、Designation: E2877 121Standard Guide forDigital Contact Thermometers1This standard is issued under the fixed designation E2877; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indi
2、cates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEChanges were made editorially in February 2013.1. Scope1.1 This Guide describes general-purpose, digital contactthermometers (hereafter simply called “digital thermomet
3、ers”)that provide temperature readings in units of degrees Celsius ordegrees Fahrenheit, or both. The different types of temperaturesensors for these thermometers are described, and their relativemerits are discussed. Nine accuracy classes are introduced fordigital thermometerhes; these classes cons
4、ider the accuracy ofthe sensor/measuring-instrument unit.1.2 The proposed accuracy classes for digital thermometerspertain to the temperature interval of 200 C to 500 C, aninterval of special interest for many applications in thermom-etry. All of the temperature sensor types for the digitalthermomet
5、ers discussed are able to measure temperature overat least some range within this interval. Some types are alsoable to measure beyond this interval.To qualify for an accuracyclass, the thermometer must measure correctly to within aspecified value (in units of C) over this interval or over thesubinte
6、rval in which they are capable of making measure-ments. Those thermometers that can measure temperature inranges beyond this interval generally have larger measurementuncertainty in these ranges.1.3 The digital thermometer sensors discussed are platinumresistance sensors, thermistors, and thermocoup
7、les. The rangeof use for these types of sensors is provided. The measurementuncertainty of a sensor is determined by its tolerance class orgrade and whether the sensor has been calibrated.1.4 This Guide provides a number of recommendations forthe manufacture and selection of a digital thermometer. F
8、irst, itrecommends that the thermometers sensor conform to appli-cable ASTM specifications. Also, it recommends minimumstandards for documentation on the thermometer and informa-tional markings on the probe and measuring instrument.1.5 The derived SI units (degrees Celsius) found in thisGuide are to
9、 be considered standard. However, thermometersdisplaying degrees Fahrenheit are compliant with this guide aslong as all other guidance is followed.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this sta
10、ndard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Some specifichazards statements are given in Section 7 on Hazards.2. Referenced Documents2.1 ASTM Standards:2E230 Specification and Temperature-Electromotive Force(EMF
11、) Tables for Standardized ThermocouplesE344 Terminology Relating to Thermometry and Hydrom-etryE563 Practice for Preparation and Use of an Ice-Point Bathas a Reference TemperatureE608/E608M Specification for Mineral-Insulated, Metal-Sheathed Base Metal ThermocouplesE644 Test Methods for Testing Indu
12、strial Resistance Ther-mometersE839 Test Methods for Sheathed Thermocouples andSheathed Thermocouple CableE879 Specification for Thermistor Sensors for General Pur-pose and Laboratory Temperature MeasurementsE1137/E1137M Specification for Industrial Platinum Resis-tance ThermometersE2181/E2181M Spec
13、ification for Compacted Mineral-Insulated, Metal-Sheathed, Noble Metal Thermocouplesand Thermocouple CableE2593 Guide for Accuracy Verification of Industrial Plati-num Resistance ThermometersE2846 Guide for Thermocouple Verification3. Terminology3.1 Definitions: The definitions given in Terminology
14、E344apply to terms used in this guide.1This guide is under the jurisdiction of ASTM Committee E20 on TemperatureMeasurement and is the direct responsibility of Subcommittee E20.09 on DigitalContact Thermometers.Current edition approved Nov. 1, 2012. Published December 2012. DOI:10.1520/E2877122For r
15、eferenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, W
16、est Conshohocken, PA 19428-2959. United States13.2 Definitions:3.2.1 accuracy class, nclass of an item that meets certainmetrological requirements intended to keep errors withinspecified limits.3.2.1.1 DiscussionThis document describes accuracyclasses for digital thermometers.3.2.2 calibration uncer
17、tainty, nparameter, derived fromthe analysis of a calibration of a measuring instrument, thatcharacterizes the range in which the true calibration result isestimated to lie within a given confidence level.3.2.3 digital contact thermometer, na device that mea-sures temperature through direct contact
18、with a sensor andprovides a digital output or display of the determined value, orboth.3.2.3.1 DiscussionThis device consists of a temperaturesensor connected to a measuring instrument; this instrumentmeasures the temperature-dependent quantity of the sensor,computes the temperature from the measured
19、 quantity, andprovides a digital output or display of the temperature, or both.The sensor is sometimes located inside the instrument.3.2.4 measuring instrument, nthe instrument in a digitalthermometer that is used to measure the temperature-dependentquantity of the sensor.3.2.5 probe, nan assembly,
20、including the transducer(sensor), that is used to position the transducer in the specificlocation at which the temperature is to be measured.3.2.6 reference-junction compensator, na device that mea-sures the temperature of a thermocouples reference junctionand adds to or subtracts from the reference
21、-junction emf acompensating voltage that simulates a reference junctiontemperature of 0 C.3.2.6.1 DiscussionThe compensating voltage may beadded or subtracted electronically or digitally.3.2.7 response time, nthe time required for a sensor tochange a specified percentage of the total difference betw
22、eenits initial and final temperatures when the sensor is subjected toa step function change in temperature.3.2.8 sensing point, nthe location on a temperature sensorwhere the temperature is (or is assumed to be) measured.3.2.8.1 DiscussionA thermocouples sensing point is itsmeasuring junction (altho
23、ugh the signal in the thermocouple isgenerated along the two thermocouple wires in regions wherea temperature gradient exists).Aplatinum resistance thermom-eter contains a sensing element that may be large enough toexperience spatial temperature variations; in this case thesensing point is the centr
24、al point in the element where thetemperature is assumed to be that measured by the platinumresistance thermometer.3.2.9 time constant, nthe 63.2 % response time of a sensorthat exhibits a single-exponential response.3.2.10 tolerance, nin a measurement instrument, the per-mitted variation of a measur
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME28772012E1STANDARDGUIDEFORDIGITALCONTACTTHERMOMETERS 数字 接触 温度计 标准 指南 PDF

链接地址:http://www.mydoc123.com/p-532042.html