ASTM E2767-2013(2018) Standard Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) for X-ray Computed Tomography (CT) Test Methods.pdf
《ASTM E2767-2013(2018) Standard Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) for X-ray Computed Tomography (CT) Test Methods.pdf》由会员分享,可在线阅读,更多相关《ASTM E2767-2013(2018) Standard Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) for X-ray Computed Tomography (CT) Test Methods.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2767 13 (Reapproved 2018)Standard Practice forDigital Imaging and Communication in NondestructiveEvaluation (DICONDE) for X-ray Computed Tomography (CT)Test Methods1This standard is issued under the fixed designation E2767; the number immediately following the designation indicates the
2、 year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This practice facilitates the interoperability of
3、X-raycomputed tomography (CT) imaging equipment by specifyingimage data transfer and archival storage methods in commonlyaccepted terms. This document is intended to be used inconjunction with Practice E2339 on Digital Imaging andCommunication in Nondestructive Evaluation (DICONDE).Practice E2339 de
4、fines an industrial adaptation of the NEMAStandards Publication titled Digital Imaging and Communica-tions in Medicine (DICOM, see http:/medical.nema.org), aninternational standard for image data acquisition, review,storage and archival storage. The goal of Practice E2339,commonly referred to as DIC
5、ONDE, is to provide a standardthat facilitates the display and analysis of NDE test results onany system conforming to the DICONDE standard. Towardthat end, Practice E2339 provides a data dictionary and a set ofinformation modules that are applicable to all NDE modalities.This practice supplements P
6、ractice E2339 by providing infor-mation object definitions, information modules and a datadictionary that are specific to X-ray CT test methods.1.2 This practice has been developed to overcome the issuesthat arise when analyzing or archiving data from tomographictest equipment using proprietary data
7、 transfer and storagemethods. As digital technologies evolve, data must remaindecipherable through the use of open, industry-wide methodsfor data transfer and archival storage. This practice defines amethod where all the X-ray CT technique parameters and testresults are communicated and stored in a
8、standard mannerregardless of changes in digital technology.1.3 This practice does not specify:1.3.1 A testing or validation procedure to assess an imple-mentations conformance to the standard.1.3.2 The implementation details of any features of thestandard on a device claiming conformance.1.3.3 The o
9、verall set of features and functions to be ex-pected from a system implemented by integrating a group ofdevices each claiming DICONDE conformance.1.4 Although this practice contains no values that requireunits, it does describe methods to store and communicate datathat do require units to be properl
10、y interpreted. The valuesstated in SI units are to be regarded as standard. No other unitsof measurement are included in this standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to est
11、ablish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principle
12、s for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2E1316 Terminology for Nondestructive ExaminationsE1441 Guide for Computed Tomography (CT) ImagingE
13、2339 Practice for Digital Imaging and Communication inNondestructive Evaluation (DICONDE)2.2 Other Standard:3DICOM National Electrical Manufacturers AssociationStandard for Digital Imaging and Communication inMedicine (DICOM), 2011.3. Terminology3.1 Definitions:1This practice is under the jurisdicti
14、on of ASTM Committee E07 on Nonde-structive Testing and is the direct responsibility of Subcommittee E07.11 on DigitalImaging and Communication in Nondestructive Evaluation (DICONDE).Current edition approved June 1, 2018. Published July 2018. Originally approvedin 2010. Last previous edition approve
15、d in 2013 as E2767 - 13. DOI:10.1520/E2767-13R18.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available f
16、rom National Electrical Manufacturers Association (NEMA), 1300N. 17th St., Suite 1752, Rosslyn, VA 22209, http:/www.nema.org.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United Sta
17、tesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Tr
18、ade (TBT) Committee.13.1.1 Nondestructive evaluation terms used in this practicecan be found in Standard Terminology for NondestructiveExaminations, E1316.3.1.2 Computed Tomography terms used in this practice canbe found in Standard Guide for Computed Tomography (CT)Imaging, E1441.3.1.3 DICONDE term
19、s used in this practice are defined inPractice E2339.4. Summary of Practice4.1 A fundamental principle of DICONDE is the use ofstandard definitions and attribute formats for data communica-tion and storage. This means all systems that are DICONDEcompliant use a common data dictionary and common com-
20、munication protocols. To further standardization, the elementsin the data dictionary are organized into common groupsreferred to as information modules. The data dictionary andinformation modules common to all NDE modalities aredefined in Practice E2339.4.2 The data dictionary and information module
21、s specifiedin Practice E2339 do not cover the information storagerequirements for each individual modality (CT, DR, CR, UT,etc.). Additions to the data dictionary and information modulesare required to support the individual modalities. This practicecontains the additions to the DICONDE data diction
22、ary andinformation modules necessary for X-ray CT inspection.4.3 The highest organizational level in the DICONDEinformation model is the information object definition (IOD).An information object definition is a collection of the infor-mation modules necessary to represent a set of test results froma
23、 specific modality. This practice contains information objectdefinitions for X-ray CT inspection.5. Significance and Use5.1 Personnel that are responsible for the creation, transfer,and storage of X-ray tomographic NDE data will use thisstandard. This practice defines a set of information modulestha
24、t along with Practice E2339 and the DICOM standardprovide a standard means to organize X-ray tomography testparameters and results. The X-ray CT test results may bedisplayed and analyzed on any device that conforms to thisstandard. Personnel wishing to view any tomographic inspec-tion data stored ac
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME276720132018STANDARDPRACTICEFORDIGITALIMAGINGANDCOMMUNICATIONINNONDESTRUCTIVEEVALUATIONDICONDEFORXRAYCOMPUTEDTOMOGRAPHYCTTESTMETHODSPDF

链接地址:http://www.mydoc123.com/p-531854.html