ASTM E2717-2011 Standard Practice for Estimating the Environmental Load of Residential Wastewater《居民污水环境载荷估算规程》.pdf
《ASTM E2717-2011 Standard Practice for Estimating the Environmental Load of Residential Wastewater《居民污水环境载荷估算规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2717-2011 Standard Practice for Estimating the Environmental Load of Residential Wastewater《居民污水环境载荷估算规程》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2717 11Standard Practice forEstimating the Environmental Load of ResidentialWastewater1This standard is issued under the fixed designation E2717; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisi
2、on. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice provides a set of instructions for estimat-ing the environmental load of residential water, as it isdischarged from
3、 a residence. The environmental load is calcu-lated based on the number and type of fixtures in the home, thecommon household chemicals used, and the number of peoplein the home. While the format is broadly applied internation-ally, the parameters stated herein reflect North Americanaverages and wou
4、ld need to be modified if used elsewhere.1.1.1 Averages MethodThe Averages Method provides anestimate of the annual environmental load for the average U.S.single-family home based on 2000 U.S. Census and 2007U.S. Census Data and U.S. EPA/625/R-00/008 characterizationof residential wastewater flows.1
5、.1.2 Unique Product Parameters MethodThe UniqueProduct Parameters Method provides an estimate of the annualenvironmental load, where the home/product parameter valuesare the same as those used for the Averages Method except forestimated amounts of chemical contaminants listed in Table 1or average to
6、tal annual use of products as listed in Table 1,orboth.1.1.3 Adjusted Averages MethodThe Adjusted AveragesMethod provides an estimate of the annual environmental load,where home/product parameter values differ from those usedfor the Averages Method, except that chemical contaminantsassociated with p
7、roducts do not vary. (Table 1 remains thesame for: Typical Water Contaminants, Estimated Amount ofContaminant in Product (%), and the Percent Waste.)1.1.4 Additional/Alternative Chemicals MethodTheAdditional/Alternative Chemicals Method provides an esti-mate of the annual environmental load, of chem
8、icals used thatare not listed in Table 1.1.1.5 The Unique Product Parameters Method, AdjustedAverages Method, and Additional Chemicals Method may beused in combination with each other.1.2 Instructions are provided for a single-family home.Estimates may be expanded to an aggregate number ofsingle-fam
9、ily homes by assuming an average home size andmultiplying by the number of homes. Estimates may beadapted to multi-unit residential buildings by factoring thehome parameters for size, occupancy, and fixtures as necessary.1.3 For the purpose of this practice, environmental loadrefers to chemical cont
10、aminants that may be dissolved orsuspended in water.1.3.1 Estimates of environmental load do not include or-ganic matter common for urine, feces, and vomit.1.3.2 Estimates of environmental load do not include bulkfood waste such as kitchen scraps.1.3.3 Estimates of environmental load do not include
11、bulkcellulose waste such as toilet paper.1.3.4 Actual environmental load may vary depending ontypes and amounts of chemicals used in a specific home and thenumber of people in the home.1.4 The values stated in inch-pound units are to be regardedas standard. No other units of measurement are included
12、 in thisstandard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to us
13、e.2. Referenced Documents2.1 ASTM Standards:2E2114 Terminology for Sustainability Relative to the Per-formance of Buildings1This practice is under the jurisdiction of ASTM Committee E60 on Sustain-ability and is the direct responsibility of Subcommittee E60.01 on Buildings andConstruction.Current ed
14、ition approved Jan. 1, 2011. Published January 2011. DOI: 10.1520/E2717-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe
15、 ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.TABLE 1 Chemical Contaminants Attributable to WastewaterProduct Type Typical UsesTypical WaterContaminantsAverage TotalProduct UsedPer YearAssumptionsEstimated Amountof Co
16、ntaminantin Product (%)Percent WasteAntiperspirant /DeodorantControls sweat andbody odor (feet,underarms, genitalia)AluminumA66.56 oz/year Usage per year isbased on 10 sticks perperson22.22 65 95Bar Soap Used for daily hygiene Sodium Salts 48 oz/year Usage per year isbased on 1 bar amonth per reside
17、nce80 100Liquid Soap(hand anddishwashing)Used for daily hygiene Sodium Salts 90 oz/year Usage per year isbased on 1 bottle amonth per residence3 100Shampoo Used for daily hygiene Propylene Glycol 174 oz/year Usage per year isbased on 1 bottle amonth per residence6 100Sodium LaruethSulfate30Mouthwash
18、 Used to enhance oralhygieneEthanol 277.92 Usage per year isbased on 23.16 oz permonth20.48 95Pharmaceuticals alleviate pain andimprove healthvaries #1.87 lb/year passed through urineBvaries 100varies 0.03 lb disposed (dumped) inwaste watervariesBleach removal of stains fromlaundrySodium hypochlorit
19、e 624 oz/year usage per applicationbased on 2 washes aweek.6.78 5 100Disinfectant removal of mold andmildew; cleanser fortoilets and dishwasherSodium hypochlorite 324 oz/year (found inspray cleaners)usage per applicationis based on overallcleaning regime onceevery two weeks.2.73 37.5 50cleaning tubs
20、 andsinksAmmonium Hydroxide 336 oz/year usage per applicationis based on overallcleaning regime onceevery two weeks.7.5 95 100Drain Cleaner Unclogs drains.Dissolves grease andhair.Sodium hydroxide orpotassium hydroxide64 oz/year Drain cleanser wouldnot be used in aregular cleaningregimen. Usage woul
21、dresult from uniquesituations. Assumeaverage usage is 16oz per application.Assume 64 oz is theaverage amountneeded per year.Sodium Hydroxide:2.32 PotassiumHydroxide: 47.5100Automatic DishwasherSoapUsed for cleaningdishesPhosphates 378 oz/year Usage per year isbased on 31.5 oz permonth30 100Laundry D
22、etergent Used to remove dirt,oil, grease, and stainsfrom clothes. Sanitizesclothes and mayprovide a fragrance tothe fibers.Ethanol/SD Alcohol 40 208 oz/year usage per applicationbased on 2 large loadwashes a week, using2 oz per wash.0.67 5 100Sodium tetraborateanhydrous0.83 5Monoethanolamine(MEA)0.6
23、7 2.67Toilet Bowl Cleaner sanitize and removestainsHydrochloric Acid 96 oz/year usage per applicationis based on overallcleaning regime onceevery two weeks.10.19 100E2717 1122.2 Other References:2000 U.S. Census32007 U.S. Census Data4U.S. EPA/625/R-00/008 Onsite Wastewater Treatment Sys-tems Manual,
24、 February 2002 (U.S. EPA characterizationof residential wastewater flows)53. Terminology3.1 DefinitionsFor terms related to sustainability relativeto the performance of buildings, refer to Terminology E2114.3.2 Definitions of Terms Specific to This Standard:3.2.1 environmental load, nchemical contam
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME27172011STANDARDPRACTICEFORESTIMATINGTHEENVIRONMENTALLOADOFRESIDENTIALWASTEWATER 居民 污水 环境 载荷 估算

链接地址:http://www.mydoc123.com/p-531755.html