ASTM E2707-2015 Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure《使用直接火焰接触暴露方法测定外墙组件火焰穿透性的标准试验方法》.pdf
《ASTM E2707-2015 Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure《使用直接火焰接触暴露方法测定外墙组件火焰穿透性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2707-2015 Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure《使用直接火焰接触暴露方法测定外墙组件火焰穿透性的标准试验方法》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2707 14E2707 15 An American National StandardStandard Test Method forDetermining Fire Penetration of Exterior Wall AssembliesUsing a Direct Flame Impingement Exposure1This standard is issued under the fixed designation E2707; the number immediately following the designation indicates t
2、he year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This fire-test-response standard prescribes a met
3、hod to assess the fire performance of a vertically oriented specimen exposedto direct flame impingement in a simulated external fire exposure potentially encountered in a Wildland Urban Interfacescenario.This test method provides data suitable for comparing the performance of materials, which are us
4、ed as the exposed surfaces ofexterior walls in construction applications.NOTE 1This test method closely follows the test procedure of California Office of State Marshal (SFM) Method 12-7A-1.21.2 This test method measures the ability of the wall system to resist fire penetration from the exterior int
5、o the wall cavity orunexposed side of the test assembly under the conditions of exposure.1.3 This test method provides data suitable for comparing the performance of vertically oriented materials, products orassemblies in exterior construction applications. The test specimen shall be tested in thick
6、nesses and configurations representativeof actual end product or system uses.1.4 Limitations of the test method are listed in Section 5.5.1.5 The system of units to be used in referee decisions is the SI system of units; see IEEE/ASTM SI-10 for further details. Theunits given in parentheses are for
7、information only.1.6 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame undercontrolled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials,products, or assemblies
8、 under actual fire conditions.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations
9、prior to use.1.8 Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting thesetests.2. Referenced Documents2.1 ASTM Standards:3D2898 Practice for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire TestingD4442 Test Methods for
10、Direct Moisture Content Measurement of Wood and Wood-Based MaterialsD4444 Test Method for Laboratory Standardization and Calibration of Hand-Held Moisture MetersD6662 Specification for Polyolefin-Based Plastic Lumber Decking BoardsD7032 Specification for Establishing Performance Ratings for Wood-Pla
11、stic Composite Deck Boards and Guardrail Systems(Guards or Handrails)E176 Terminology of Fire StandardsE1354 Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen ConsumptionCalorimeter1 This test method is under the jurisdiction ofASTM Committee E05 on Fire
12、 Standards and is the direct responsibility of Subcommittee E05.14 on External Fire Exposures.Current edition approved July 15, 2014Oct. 1, 2015. Published August 2014November 2015. Originally approved in 2009. Last previous edition approved in 20092014as E270709.14. DOI: 10.1520/E2707-14.10.1520/E2
13、707-15.2 2007 California Building Code, Chapter 7A SFM, Materials and Construction Methods for Exterior Wildfire Exposure, Exterior Wall Siding and Sheathing, SFMStandard 12-7A-1.3 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org.
14、For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may
15、 not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbo
16、r Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1E1474 Test Method for Determining the Heat Release Rate of Upholstered Furniture and Mattress Components or CompositesUsing a Bench Scale Oxygen Consumption CalorimeterE1740 Test Method for Determining the Heat Release Rate and Ot
17、her Fire-Test-Response Characteristics of Wall Covering orCeiling Covering Composites Using a Cone CalorimeterE2102 Test Method for Measurement of Mass Loss and Ignitability for Screening Purposes Using a Conical Radiant HeaterE2257 Test Method for Room Fire Test of Wall and Ceiling Materials and As
18、sembliesE2886 Test Method for Evaluating the Ability of Exterior Vents to Resist the Entry of Embers and Direct Flame ImpingementIEEE/ASTM SI-10 American National Standard for Use of the International System of Units (SI): The Modern Metric System2.2 ISO Standards:ISO 13943 Fire SafetyVocabulary43.
19、Terminology3.1 DefinitionsFor definitions of terms used in this standard, see Terminology E176 and ISO 13943. In case of conflict, thedefinitions given in Terminology E176 shall prevail.3.2 Definitions of Terms Specific to This Standard:3.2.1 orientation, nthe vertical plane in which the exposed fac
20、e of the test specimen is located during testing.3.2.2 siding (cladding), nany material that constitutes the exposed exterior covering of an exterior wall and such material isapplied over sheathing or directly attached to the wall system.3.2.3 sheathing, nthe material placed on an exterior wall bene
21、ath cladding or siding and directly attached to the wall systemused over the wall framework and is attached directly to the wall framing members. Materials called sheathing that are not placedbeneath cladding or siding shall be classified as cladding or siding.3.2.4 sustained flaming, nflame on or o
22、ver the surface of a test specimen that lasts longer than a period of 4 s.4. Summary of Test Method4.1 This test method provides for the direct flame exposure of a wall specimen to a flame source centered at the base of a 1220by 2440 mm (4 by 8 ft) test assembly.4.2 This test method employs a gas bu
23、rner to produce a diffusion flame in contact with the test wall assembly.4.3 The gas burner produces a prescribed net rate of heat output of 150 kW (8535 BTU/min) for a period of 10 min, after whichthe flame exposure is terminated.4.4 The test method measures the ability of the wall system to resist
24、 fire penetration from the exterior to the unexposed sideof the test assembly under the conditions of exposure. Observations are made for the appearance of sustained flaming or glow onthe unexposed side or sustained glowing on the unexposed side, or both, at the end of a 60 min observation period.5.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME27072015STANDARDTESTMETHODFORDETERMININGFIREPENETRATIONOFEXTERIORWALLASSEMBLIESUSINGADIRECTFLAMEIMPINGEMENTEXPOSURE

链接地址:http://www.mydoc123.com/p-531730.html