ASTM E2698-2018 Standard Practice for Radiographic Examination Using Digital Detector Arrays《用数字探测器阵列进行射线照相检查的标准实施规程》.pdf
《ASTM E2698-2018 Standard Practice for Radiographic Examination Using Digital Detector Arrays《用数字探测器阵列进行射线照相检查的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2698-2018 Standard Practice for Radiographic Examination Using Digital Detector Arrays《用数字探测器阵列进行射线照相检查的标准实施规程》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2698 10E2698 18Standard Practice forRadiologicalRadiographic Examination Using DigitalDetector Arrays1This standard is issued under the fixed designation E2698; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、 of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice establishes the minimum requirements for radiologicalradiographic examination forof metallic andnonm
3、etallic materialmaterials using a digital detector array (DDA) system.arrays (DDAs).1.2 The stated requirements of this specification are based on the use of an X-ray generating source. Additionally, some of thetests and requirements may not be applicable to X-ray energy levels 450kV.1.3 The require
4、ments in this practice are intended to control the quality of radiologic images radiographic examinations obtainedusing DDAs and are not intended to establish acceptance criteria for parts or materials.1.4 This practice covers the radiologicradiographic examination with DDAs including DDAs described
5、 in PracticeE2597E2597/E2597M such as a device that contains a photoconductor attached to a Thin Film Transistor (TFT) read out structure,a device that has a phosphor coupled directly to an amorphous silicon read-out structure, and devices where a phosphor is coupledto a CMOS (Complementary(compleme
6、ntary metaloxidesemiconductor) array, a Linear DetectorArray (LDA) or a CCD (chargecoupled device) crystalline silicon read-out structure.1.5 The requirements of this practice and Practice E2737 shall be used together. The requirements of Practice E2737 willprovide the baseline evaluation and long t
7、erm stability test procedures for the DDA system. The user of the DDA system shallestablish a written procedure that addresses the specific requirements and tests to be used in their application and shall be approvedby the Cognizant Radiographic Level 3 before examination of production hardware. Thi
8、s practice also requires the user to performa system qualification suitable for its intended purpose and to issue a system qualification report (see 9.1).1.6 The DDA shall be selected for an NDT application based on knowledge of the technology described in Guide E2736, andof the selected DDA propert
9、ies provided by the manufacturer in accordance with Practice E2597E2597/E2597M.1.5 The requirements of this practice and Practice E2737 shall be used together and both be approved by the CEO Level 3 inRadiography before inspection of production hardware. The requirements of Practice E2737 will provi
10、de the baseline evaluationand long term stability test procedures for the DDA system.1.6 The requirements in this practice shall be used when placing a DDAinto NDT service and, before being placed into service,an established baseline of system qualification shall be performed in accordance with Prac
11、tice E2737.1.7 Techniques and applications employed with DDAs are diverse. This practice is not intended to be limiting or restrictive.Refer to Guides E94E94/E94M, E1000, and E2736,Terminology E1316, PracticePractices E747 and E1025, Fed. Std. Nos. 21CFR1020.40 and 29 CFR 1910.96 and Federal Standar
12、ds 21-CFR-1020.40 and 29-CFR-1910.96 for a list of documents that provideadditional information and guidance.1.8 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of Inter
13、national Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2E94E94/E94M Guide for Radiographic Examination Using Industrial Radiographic Film1 This practice is under the jurisdiction ofAST
14、M Committee E07 on Nondestructive Testing and is the direct responsibility of Subcommittee E07.01 on Radiology (X andGamma) Method.Current edition approved April 15, 2010Feb. 1, 2018. Published July 2010April 2018. Originally approved in 2010. Last previous edition approved in 2010 as E2698 10.DOI:
15、10.1520/E2698-18.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is
16、 intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the
17、current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1E543 Specification for Agencies Performing Nondestructive TestingE747 Practice for Design, M
18、anufacture and Material Grouping Classification of Wire Image Quality Indicators (IQI) Used forRadiologyE1000 Guide for RadioscopyE1025 Practice for Design, Manufacture, and Material Grouping Classification of Hole-Type Image Quality Indicators (IQI)Used for RadiographyE1165 Test Method for Measurem
19、ent of Focal Spots of Industrial X-Ray Tubes by Pinhole ImagingE1316 Terminology for Nondestructive ExaminationsE1647E1742/E1742M Practice for Determining Contrast Sensitivity in RadiologyRadiographic ExaminationE1742E1817 Practice for Radiographic ExaminationControlling Quality of Radiological Exam
20、ination by Using RepresentativeQuality Indicators (RQIs)E2002 Practice for Determining Total Image Unsharpness and Basic Spatial Resolution in Radiography and RadioscopyE2339 Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE)E2597E2597/E2597M Practice for Manufactu
21、ring Characterization of Digital Detector ArraysE2699 Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) for Digital Radiographic(DR) Test MethodsE2736 Guide for Digital Detector ArraysArray RadiographyE2737 Practice for Digital Detector Array Performance Evaluatio
22、n and Long-Term StabilityE2903 Test Method for Measurement of the Effective Focal Spot Size of Mini and Micro Focus X-ray Tubes2.2 AWS Documents:3AWS A2.4 Symbols for Welding and Nondestructive Testing2.3 Aerospace Industries Association Document:4NAS 410 Certification the model and manufacturer of
23、the x-ray tube and the focal spot size.e.1) The nominal exposure: voltage, current, exposure time, frame rate, frames averaged, beam and/or detector collimation, beam filters used including their loca-tions (tube, part, detector, and so forth)f.) For radioisotope source exposures: the isotope type a
24、nd source size.f.1) The nominal exposure: source strength, exposure time, frame rate, frames averaged, beam and/or detector collimation, beam filters used including their loca-tions (tube, part, detector, and so forth).g.) The make, model, and manufacturer of the DDA used in the examination. The det
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME26982018STANDARDPRACTICEFORRADIOGRAPHICEXAMINATIONUSINGDIGITALDETECTORARRAYS 数字 探测器 阵列 进行 射线 照相

链接地址:http://www.mydoc123.com/p-531720.html