1、Designation: E2698 10Standard Practice forRadiological Examination Using Digital Detector Arrays1This standard is issued under the fixed designation E2698; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice establishes the minimum requirements forradiological examination for metallic and nonmetallic materialusing a digital d
3、etector array (DDA) system.1.2 The requirements in this practice are intended to controlthe quality of radiologic images and are not intended toestablish acceptance criteria for parts or materials.1.3 This practice covers the radiologic examination withDDAs including DDAs described in Practice E2597
4、 such as adevice that contains a photoconductor attached to a Thin FilmTransistor (TFT) read out structure, a device that has aphosphor coupled directly to an amorphous silicon read-outstructure, and devices where a phosphor is coupled to a CMOS(Complementary metaloxidesemiconductor) array, a Linear
5、Detector Array (LDA) or a CCD (charge coupled device)crystalline silicon read-out structure.1.4 The DDA shall be selected for an NDT applicationbased on knowledge of the technology described in GuideE2736, and of the selected DDA properties provided by themanufacturer in accordance with Practice E25
6、97.1.5 The requirements of this practice and Practice E2737shall be used together and both be approved by the CEO Level3 in Radiography before inspection of production hardware.The requirements of Practice E2737 will provide the baselineevaluation and long term stability test procedures for the DDAs
7、ystem.1.6 The requirements in this practice shall be used whenplacing a DDA into NDT service and, before being placed intoservice, an established baseline of system qualification shall beperformed in accordance with Practice E2737.1.7 Techniques and applications employed with DDAs arediverse. This p
8、ractice is not intended to be limiting or restric-tive. Refer to Guides E94, E1000, E2736, Terminology E1316,Practice E747 and E1025, Fed. Std. Nos. 21CFR 1020.40 and29 CFR 1910.96 for a list of documents that provide additionalinformation and guidance.2. Referenced Documents2.1 ASTM Standards:2E94
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME26982010STANDARDPRACTICEFORRADIOLOGICALEXAMINATIONUSINGDIGITALDETECTORARRAYS 使用 数字 检测器 阵列 进行 放射学

链接地址:http://www.mydoc123.com/p-531719.html