ASTM E2638-2010 Standard Test Method for Objective Measurement of the Speech Privacy Provided by a Closed Room《用封闭房间提供的隔音客观测量用标准试验方法》.pdf
《ASTM E2638-2010 Standard Test Method for Objective Measurement of the Speech Privacy Provided by a Closed Room《用封闭房间提供的隔音客观测量用标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2638-2010 Standard Test Method for Objective Measurement of the Speech Privacy Provided by a Closed Room《用封闭房间提供的隔音客观测量用标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2638 10Standard Test Method forObjective Measurement of the Speech Privacy Provided bya Closed Room1This standard is issued under the fixed designation E2638; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year o
2、f last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis test method is one of a set of standards for evaluating speech privacy in buildings. It isdesigned to measure t
3、he degree of speech privacy provided by a closed room, indicating the degreeto which conversations occurring within are kept private from listeners outside the room. A relatedmethod (Test Method E1130) deals with assessing speech privacy in open plan spaces.1. Scope1.1 This test method describes a t
4、est procedure for measur-ing the degree of speech privacy provided by a closed room,for conversations occurring within the room, and with potentialeavesdroppers located outside the room.1.2 The degree of speech privacy measured by this methodis that due to the sound insulation of the room structuret
5、hewalls, floor, ceiling and any other elements of the roomboundariesand to the background noise at listening positionsoutside the closed the room.1.3 Potential eavesdroppers are assumed to be unaided byelectronic or electroacoustic equipment, and not touching theroom boundaries. Determined efforts t
6、o eavesdrop are notaddressed.1.4 The method may be applied to any enclosed room,whether specifically intended to be protected against eaves-dropping or not.1.5 The method does not set criteria for adequate speechprivacy. A non-mandatory appendix provides guidance on howthe results of this test metho
7、d may be used to estimate theprobability of an eavesdropper being able to understand speechoutside a closed room, and how to set criteria for such rooms.1.6 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.7 This standard does
8、not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standa
9、rds:2C634 Terminology Relating to Building and EnvironmentalAcousticsE1130 Test Method for Objective Measurement of SpeechPrivacy in Open Plan Spaces Using Articulation Index2.2 ANSI Standards:S1.11 Specification for Octave-Band and Fractional-Octave-Band Analog and Digital Filters3S1.43 Specificati
10、ons for Integrating-Averaging Sound LevelMeters33. Terminology3.1 The following terms used in this test method havespecific meanings that are defined in Terminology C634:airborne sound sound attenuationaverage sound pressure level sound isolationbackground noise sound leveldecibel sound pressure lev
11、ellevel source roomoctave band white noisepink noise3.2 Definitions of Terms Specific to This Standard:3.2.1 receiving pointa location outside the closed roomunder consideration where someone might accidentally over-hear or deliberately listen to speech occurring within the room.3.2.2 speech privacy
12、 class (SPC)an objective rating of thespeech privacy provided by a closed room, calculated as a sumof factors related to sound isolation provided by the room, andbackground noise at the receiving point.1This test method is under the jurisdiction ofASTM Committee E33 on Buildingand Environmental Acou
13、stics and is the direct responsibility of SubcommitteeE33.03 on Sound Transmission.Current edition approved May 1, 2010. Published May 2010. Originallyapproved in 2008. Last previous edition approved in 2008 as E263808 DOI:10.1520/E2638-10.2For referenced ASTM standards, visit the ASTM website, www.
14、astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ans
15、i.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4. Summary of Test Method4.1 Sound is generated at a high level in the closed roomunder consideration. To improve spatial uniformity, a sourceloudspeaker is to be placed successiv
16、ely at two or morelocations within the room.4.2 Receiving points outside the closed room under consid-eration that are near potential weak spots in the soundinsulation or that are possible locations for an eavesdropper areselected for measurement.4.3 With the source operating in each successive loca
17、tion,measurements of sound pressure level are made within theclosed room to obtain source room levels, and at receivingpoints outside the closed room to obtain received levels.4.4 With the source turned off, measurements of soundpressure level are made at the receiving points to obtainbackground noi
18、se levels.4.5 The differences in average source room levels inside theclosed room and received levels at each receiving point aredetermined, and are used to calculate a single number for eachreceiving point that indicates the degree of sound isolationprovided by the room boundaries.4.6 The single nu
19、mber rating of sound isolation is combinedwith the measured background noise levels to obtain theSpeech Privacy Classa single number rating for each receiv-ing point that is related to the degree of speech privacy at eachreceiving point.5. Significance and Use5.1 This test method provides a means of
20、 measuring thesound isolation between the interior of a closed room andlocations outside the room, and also the background noiselevels at the locations outside the room. The results can be usedto rate the degree of speech privacy, or to estimate theprobability of speech being intelligible or audible
21、 at eachreceiving point.5.2 People speak at different levels and vary their voicelevel in reaction to room noise and other acoustical factors.Consequently it is not possible to say definitely whether a roomis protected against eavesdropping. One can only assign aprobability of being overheard. The o
22、wners or managers of theclosed room under consideration must set criteria for thisprobability according to their specific goals and circumstances.The non-mandatory appendix gives an approach to settingcriteria.6. Sound Sources6.1 Sound sources shall be loudspeaker systems driven bypower amplifiers.6
23、.2 The input signal to the amplifiers shall be random noisecontaining an approximately uniform and continuous distribu-tion of energy and frequencies over each test band. White orpink electronic noise sources satisfy this condition.7. Frequency Range7.1 Bandwidth and FilteringThe overall frequency r
24、e-sponse of the electrical system, including the filter or filters inthe source and microphone sections, shall for each test bandconform to the specifications in ANSI S1.11 for a one-thirdoctave band filter set, class 1 or better.7.2 The frequency range for measurement shall be thesixteen one-third
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME26382010STANDARDTESTMETHODFOROBJECTIVEMEASUREMENTOFTHESPEECHPRIVACYPROVIDEDBYACLOSEDROOM 封闭 房间 提供

链接地址:http://www.mydoc123.com/p-531601.html