1、Designation: E 2623 081Standard Practice forReporting Thermometer Calibrations1This standard is issued under the fixed designation E 2623; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in paren
2、theses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEThe title was corrected editorially in May 2009.1. Scope1.1 This practice contains reporting requirements for ther-mometer calibrations included in ASTM Comm
3、ittee E20 TestMethods.1.2 This practice covers reports of calibration for radiationthermometers, liquid-in-glass thermometers, resistance ther-mometers, and new thermocouples.NOTE 1This practice does not apply to used thermocouples.1.3 This standard does not purport to address all of thesafety conce
4、rns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E77 Test Method for Inspection and Verif
5、ication of Ther-mometersE 344 Terminology Relating to Thermometry and Hydrom-etry2.2 Other Standards:ANSI/NCSL Z540-1-1994 American National Standard forCalibrationCalibration Laboratories and Measuring andTest EquipmentGeneral Requirements3ISO/IEC 17025:2005 General Requirements for the Com-petence
6、 of Testing and Calibration Laboratories33. Terminology3.1 DefinitionsDefinitions given in Terminology E 344,unless otherwise defined herein, apply to terms as used in thispractice.3.2 Definitions of Terms Specific to This Standard:3.2.1 correction, nnumerical value added to the uncor-rected result
7、of a measurement to compensate for errors.3.2.1.1 DiscussionThe correction is equal to the negativeof the estimated errors. Since the systematic error cannot beknown perfectly, the compensation cannot be complete.3.2.2 error, nthe indication of a thermometer or tempera-ture measuring device minus a
8、true value of the correspondinginput quantity.3.2.2.1 DiscussionSince the true value cannot be deter-mined, in practice a conventional true value is used. Thisconcept applies mainly where the instrument is compared to areference standard.3.2.3 gradient zone, nthe section of a thermocouple that isexp
9、osed during a measurement to temperatures in the rangefrom tamb+ 0.1(tm tamb)totamb+ 0.9(tm tamb), where tambisambient temperature and tmis the temperature of the measuringjunction.3.2.3.1 DiscussionThis term is used in thermocouplecalibration reports as part of the description of the thermalprofile
10、 along the length of the thermocouple. Although athermocouple emf is a function of the measuring and referencejunction temperatures, the emf is actually generated along thelength of the thermocouple, wherever the thermoelements passthrough a temperature gradient. The gradient zone definition isinten
11、ded to describe, in an approximate way, the section ofthermocouple that created most of the emf during the calibra-tion.3.2.4 half-maximum heated length, nthe distance betweenthe tip of the temperature sensor and the position along thelength of the sensor leads or sheath where the temperatureequals
12、the average of the calibration-point and ambient tem-peratures.1This practice is under the jurisdiction ofASTM Committee E20 on TemperatureMeasurement and is the direct responsibility of Subcommittee E20.07 on Funda-mentals in Thermometry.Current edition approved Nov. 1, 2008. Published January 2009
13、.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI)
14、, 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.4.1 DiscussionThis term is used in thermocouplecalibration reports as part of the description of the thermalprofil
15、e along the length of the thermocouple.4. Summary of Practice4.1 This practice describes the required information neces-sary for reporting results of temperature calibrations includedin ASTM Test Methods.5. Significance and Use5.1 This practice is adequate for use with all ASTM TestMethods which req
16、uire the reporting of temperature measure-ments.5.2 The Report of Calibration, however named, is thephysical output of the calibration laboratory. It shall beprepared so that both the results of the measurement(s) and thenon-technical information necessary to support those resultsare conveyed in a m
17、anner that ensures accurate communicationand justification of the results to the benefit of all concerned.5.3 This practice is not meant to supersede requirements ofother standards practice such as ISO/IEC 17025 or ANSI/NCSL Z540-1.6. Procedure6.1 Requirements for Written ReportThe requirements in6.
18、1.1 through 6.1.14 are mandatory for all written reportsissued in compliance with this practice. Sections 6.1.15through 6.1.19 include general provisions for information thatmay be omitted if not required by a calibration procedure orclient/user.6.1.1 Title ExamplesReport of Calibration, Calibration
19、Certificate, Test Report or Test Certificate.6.1.2 Name and address of the laboratory and locationwhere calibration was performed, if different from the labora-tory address.6.1.3 Unique identification of the report or certificate, andon each page an identification in order to ensure that the pageis
20、recognized as part of the report or certificate, a clearidentification of the end of the report or certificate, and thepage number and total number of pages.6.1.4 Name and address of the client.6.1.5 Statement and concise description of the test methodor calibration procedure used. This statement sh
21、all includerevisions and the date of the test method or calibrationprocedure. Test methods can consist of published standards(such as ASTM Test Methods), internally developed methods,or a combination of both.6.1.5.1 Information describing deviations from previouslyagreed upon procedures.6.1.6 Descri
22、ption of thermometer or thermocouple, includ-ing overall range, and if different, range calibrated. This shallalso include manufacturer, model number (as applicable),identification or unique serial number, and the condition of thethermometer or thermocouple upon receipt.6.1.7 Date of Calibration:6.1
23、.7.1 Where applicable, additional dates, including datereceived, date of report preparation and next due date may beincluded.6.1.8 Calibration ResultsThis can take the form of a tablewith reading of standard temperature, reading of test instru-ment, corrections to be applied and consistent units of
24、measureor any form of reporting as requested by the customer.6.1.8.1 When an instrument has been repaired or adjusted,the calibration results before and after repair or adjustmentshall be reported, if available.6.1.9 Conditions (for example, environmental conditions)under which the calibrations were
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME26232008E1STANDARDPRACTICEFORREPORTINGTHERMOMETERCALIBRATIONS 温度计 校准 报告 标准 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-531569.html