1、Designation: E 2623 08Standard Practice forReporting Temperature Calibrations1This standard is issued under the fixed designation E 2623; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parent
2、heses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice contains reporting requirements for tem-perature calibrations included in ASTM Test Methods.1.2 This practice includes radiation thermome
3、ters, liquid-in-glass thermometers, resistance thermometers, and new thermo-couples. The appendices include sample reports compliant withthis practice.NOTE 1This practice does not apply to used thermocouples.1.3 This standard does not purport to address all of thesafety concerns, if any, associated
4、with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E77 Test Method for Inspection and Verification of Ther-mometers
5、E 220 Test Method for Calibration of Thermocouples ByComparison TechniquesE 344 Terminology Relating to Thermometry and Hydrom-etryE 644 Test Methods for Testing Industrial Resistance Ther-mometersE 1256 Test Methods for Radiation Thermometers (SingleWaveband Type)2.2 Other Standards:ANSI/NCSL Z540-
6、1-1994 American National Standard forCalibrationCalibration Laboratories and Measuring andTest EquipmentGeneral Requirements3ISO/IEC 17025:2005 General Requirements for the Com-petence of Testing and Calibration Laboratories33. Terminology3.1 DefinitionsDefinitions given in Terminology E 344,unless
7、otherwise defined herein, apply to terms as used in thispractice.3.2 Definitions of Terms Specific to This Standard:3.2.1 correction, nnumerical value added the uncorrectedresult of a measurement to compensate for errors.3.2.1.1 DiscussionThe correction is equal to the negativeof the estimated syste
8、matic error. Since the systematic errorcannot be known perfectly, the compensation cannot be com-plete.3.2.2 error, nthe indication of a thermometer or tempera-ture measuring device minus a true value of the correspondinginput quantity.3.2.2.1 DiscussionSince the true value cannot be deter-mined, in
9、 practice a conventional true value is used. Thisconcept applies mainly where the instrument is compared to areference standard.3.2.3 gradient zone, nthe section of a thermocouple that isexposed during a measurement to temperatures in the rangefrom tamb+ 0.1(tm tamb)totamb+ 0.9(tm tamb), where tambi
10、sambient temperature and tmis the temperature of the measuringjunction.3.2.3.1 DiscussionThis term is used in thermocouplecalibration reports as part of the description of the thermalprofile along the length of the thermocouple. Although athermocouple emf is a function of the measuring and reference
11、junction temperatures, the emf is actually generated along thelength of the thermocouple, wherever the thermoelements passthrough a temperature gradient. The gradient zone definition isintended to describe, in an approximate way, the section ofthermocouple that created most of the emf during the cal
12、ibra-tion.3.2.4 half-maximum heated length, nthe distance betweenthe tip of the temperature sensor and the position along thelength of the sensor leads or sheath where the temperatureequals the average of the calibration-point and ambient tem-peratures.1This practice is under the jurisdiction ofASTM
13、 Committee E20 on TemperatureMeasurement and is the direct responsibility of Subcommittee E20.07 on Funda-mentals in Thermometry.Current edition approved . Published XXXX.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Ann
14、ual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C7
15、00, West Conshohocken, PA 19428-2959, United States.3.2.4.1 DiscussionThis term is used in thermocouplecalibration reports as part of the description of the thermalprofile along the length of the thermocouple.4. Summary of Practice4.1 This practice describes the required information neces-sary for r
16、eporting results of temperature calibrations includedin ASTM Test Methods.5. Significance and Use5.1 This practice is adequate for use with all ASTM TestMethods which require the reporting of temperature measure-ments.5.2 The Report of Calibration, however named, is thephysical output of the calibra
17、tion laboratory. It shall beprepared so that both the results of the measurement(s) and thenon-technical information necessary to support those resultsare conveyed in a manner that ensures accurate communicationand justification of the results to the benefit of all concerned.5.3 This practice is not
18、 meant to supersede requirements ofother standards practice such as ISO/IEC 17025 or ANSI/NCSL Z540-1.6. Procedure6.1 Requirements for Written ReportThe requirements in6.1.1 through 6.1.14 are mandatory for all written reportsissued in compliance with this practice. Sections 6.1.15through 6.1.19 inc
19、lude general provisions for information thatmay be omitted if not required by a calibration procedure orclient/user.6.1.1 Title ExamplesReport of Calibration, CalibrationCertificate, Test Report or Test Certificate.6.1.2 Name and address of the laboratory and locationwhere calibration was performed
20、if different from the labora-tory address.6.1.3 Unique identification of the report or certificate, andon each page an identification in order to ensure that the pageis recognized as part of the report or certificate, a clearidentification of the end of the report or certificate, and thepage number
21、and total number of pages.6.1.4 Name and address of the client.6.1.5 Statement and concise description of test method orcalibration procedure used. This statement shall include revi-sions and date of the test method or calibration procedure. Testmethods can consist of published standards (such as AS
22、TMTest Methods), internally developed methods, or a combinationof both.6.1.5.1 Information describing deviations from previouslyagreed upon procedures.6.1.6 Description of thermometer or thermocouple, includ-ing overall range, and if different, range calibrated. This shallalso include manufacturer,
23、model number (as applicable),identification or unique serial number, and the condition of thethermometer or thermocouple upon receipt.6.1.7 Date of Calibration:6.1.7.1 Where applicable, additional dates including datereceived, date of report preparation and next due date may beincluded.6.1.8 Calibra
24、tion ResultsThis can take the form of a tablewith reading of standard temperature, reading of test instru-ment, corrections to be applied and consistent units of measureor any form of reporting as requested by the customer.6.1.8.1 When an instrument has been repaired or adjusted,the calibration resu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME26232008STANDARDPRACTICEFORREPORTINGTEMPERATURECALIBRATIONSPDF

链接地址:http://www.mydoc123.com/p-531568.html