ASTM E2617-2017 Standard Practice for Validation of Empirically Derived Multivariate Calibrations《经验导出的多元校准验证的标准实施规程》.pdf
《ASTM E2617-2017 Standard Practice for Validation of Empirically Derived Multivariate Calibrations《经验导出的多元校准验证的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2617-2017 Standard Practice for Validation of Empirically Derived Multivariate Calibrations《经验导出的多元校准验证的标准实施规程》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2617 17Standard Practice forValidation of Empirically Derived Multivariate Calibrations1This standard is issued under the fixed designation E2617; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revis
2、ion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers requirements for the validation ofempirically derived calibrations (Note 1) such as calibrationsderived by
3、Multiple Linear Regression (MLR), Principal Com-ponent Regression (PCR), Partial Least Squares (PLS), Artifi-cial Neural Networks (ANN), or any other empirical calibra-tion technique whereby a relationship is postulated between aset of variables measured for a given sample under test and oneor more
4、physical, chemical, quality, or membership propertiesapplicable to that sample.NOTE 1Empirically derived calibrations are sometimes referred to as“models” or “calibrations.” In the following text, for conciseness, the term“calibration” may be used instead of the full name of the procedure.1.2 This p
5、ractice does not cover procedures for establishingsaid postulated relationship.1.3 This practice serves as an overview of techniques usedto verify the applicability of an empirically derived multivari-ate calibration to the measurement of a sample under test andto verify equivalence between the prop
6、erties calculated fromthe empirically derived multivariate calibration and the resultsof an accepted reference method of measurement to withincontrol limits established for the prespecified statistical confi-dence level.1.4 This standard does not purport to address all of thesafety concerns, if any,
7、 associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accor-dance with international
8、ly recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2E131 Terminol
9、ogy Relating to Molecular SpectroscopyE1655 Practices for Infrared Multivariate QuantitativeAnalysisE1790 Practice for Near Infrared Qualitative Analysis3. Terminology3.1 For terminology related to molecular spectroscopicmethods, refer to Terminology E131. For terminology relatedto multivariate quan
10、titative modeling refer to Practices E1655.While Practices E1655 is written in the context of multivariatespectroscopic methods, the terminology is also applicable toother multivariate technologies.3.2 Definitions of Terms Specific to This Standard:3.2.1 accuracythe closeness of agreement between a
11、testresult and an accepted reference value.3.2.2 biasthe arithmetic average difference between thereference values and the values produced by the analyticalmethod under test, for a set of samples.3.2.3 detection limitthe lowest level of a property in asample that can be detected, but not necessarily
12、 quantified, bythe measurement system.3.2.4 estimatethe constituent concentration, identification,or other property of a sample as determined by the analyticalmethod being validated.3.2.5 initial validationvalidation that is performed whenan analyzer system is initially installed or after major main
13、te-nance.3.2.6 Negative Fraction Identifiedthe fraction of samplesnot having a particular characteristic that is identified as nothaving that characteristic.1This practice is under the jurisdiction of ASTM Committee E13 on MolecularSpectroscopy and Separation Science and is the direct responsibility
14、 of Subcom-mittee E13.11 on Multivariate Analysis.Current edition approved Dec. 15, 2017. Published February 2018. Originallyapproved in 2008. Last previous edition approved in 2010 as E2617 10. DOI:10.1520/E2617-17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM
15、 Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was
16、developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.13.2.6.1 Discus
17、sionNegative Fraction Identified assumesthat the characteristic that the test measures either is or is notpresent. It is not applicable to tests with multiple possibleoutcomes.3.2.7 ongoing periodic revalidationthe quality assuranceprocess by which, in the case of quantitative calibrations, thebias
18、and precision or, in the case of qualitative calibrations, thePositive Fraction Identified and Negative Fraction Identifiedperformance determined during initial validation are shown tobe sustained.3.2.8 Positive Fraction Identifiedthe fraction of sampleshaving a particular characteristic that is ide
19、ntified as havingthat characteristic.3.2.8.1 DiscussionPositive Fraction Identified assumesthat the characteristic that the test measures either is or is notpresent. It is not applicable to tests with multiple possibleoutcomes.3.2.9 precisionthe closeness of agreement between inde-pendent test resul
20、ts obtained under stipulated conditions.3.2.9.1 DiscussionPrecision may be a measure of eitherthe degree of reproducibility or degree of repeatability of theanalytical method under normal operating conditions. In thiscontext, reproducibility refers to the use of the analyticalprocedure in different
21、laboratories, as in a collaborative study.3.2.10 quantification limitthe lowest level of a sampleproperty which can be determined with acceptable precisionand accuracy under the stated experimental conditions.3.2.11 rangethe interval between the upper and lowerlevels of a property (including these l
22、evels) that has beendemonstrated to be determined with a suitable level of preci-sion and accuracy using the method as specified.3.2.12 reference valuethe metric of a property as deter-mined by well-characterized method, the accuracy of whichhas been stated or defined, that is, another, already-vali
23、datedmethod.3.2.13 validationthe statistically quantified judgment thatan empirically derived multivariate calibration is applicable tothe measurement on which the calibration is to be applied andcan perform property estimates with, in the case of quantitativecalibrations, acceptable precision, accu
24、racy and bias or, in thecase of qualitative calibrations, acceptable Positive FractionIdentified and Negative Fraction Identified, as compared withresults from an accepted reference method.3.2.14 validation spacethe region(s) of a calibrationsmultivariate sample space populated by the independent va
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME26172017STANDARDPRACTICEFORVALIDATIONOFEMPIRICALLYDERIVEDMULTIVARIATECALIBRATIONS 经验 导出 多元 校准 验证

链接地址:http://www.mydoc123.com/p-531559.html