ASTM E2593-2007e1 Standard Guide for Accuracy Verification of Industrial Platinum Resistance Thermometers《工业用铂电阻温度计的精度验证的标准指南》.pdf
《ASTM E2593-2007e1 Standard Guide for Accuracy Verification of Industrial Platinum Resistance Thermometers《工业用铂电阻温度计的精度验证的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2593-2007e1 Standard Guide for Accuracy Verification of Industrial Platinum Resistance Thermometers《工业用铂电阻温度计的精度验证的标准指南》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2593 07e1Standard Guide forAccuracy Verification of Industrial Platinum ResistanceThermometers1This standard is issued under the fixed designation E 2593; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of l
2、ast revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEEditorial changes were made throughout in March 2008.1. Scope1.1 This guide describes the techniques and apparatus re-quired
3、 for the accuracy verification of industrial platinumresistance thermometers constructed in accordance with Speci-fication E 1137/E 1137M and the evaluation of calibrationuncertainties. The procedures described apply over the range of200 C to 650 C.1.2 This guide is not intended to describe the proc
4、eduresnecessary for the calibration of platinum resistance thermom-eters intended to be used as calibration standards or StandardPlatinum Resistance Thermometers. Consequently, calibrationof these types of instruments is outside the scope of this guide.1.3 Industrial platinum resistance thermometers
5、 are avail-able in many styles and configurations. This guide does notpurport to determine the suitability of any particular design,style, or configuration for calibration over a desired tempera-ture range.1.4 The evaluation of uncertainties is based upon currentinternational practices as described
6、in ISO/TAG 4/WG 3“Guide to the Evaluation of Uncertainty in Measurement” andANSI/NCSL Z540-2-1997 “U.S. Guide to the Expression ofUncertainty in Measurement”.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user
7、of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 344 Terminology Relating to Thermometry and Hydrom-etryE 563 Practice for Preparation and Use of an Ice-Point Ba
8、thas a Reference TemperatureE 644 Test Methods for Testing Industrial Resistance Ther-mometersE 1137/E 1137M Specification for Industrial Platinum Re-sistance ThermometersE 1502 Guide for Use of Freezing-Point Cells for ReferenceTemperaturesE 1750 Guide for Use of Water Triple Point Cells2.2 ANSI Pu
9、blication:ANSI/NCSL Z540-2-1997 U.S. Guide to the Expression ofUncertainty in Measurement32.3 Other Publication:ISO/TAG 4/WG 3 Guide to the Evaluation of Uncertainty inMeasurement3. Terminology3.1 DefinitionsThe definitions given in TerminologyE 344 shall be considered as applying to the terms used
10、in thisguide.3.2 Definitions of Terms Specific to This Standard:3.2.1 annealing, va heat treating process intended tostabilize resistance thermometers prior to calibration and use.3.2.2 check standard, na thermometer of similar designbut superior stability than the UUTs which is included in thecalib
11、ration process for the purpose of quantifying the processvariability.3.2.3 coverage factor, nnumerical factor used as a mul-tiplier of the combined standard uncertainty in order to obtainan expanded uncertainty.3.2.4 dielectric absorption, nan effect in an insulatorcaused by the polarization of posi
12、tive and negative chargeswithin the insulator which manifests itself as an in-phasecurrent when the voltage is removed and the charges recom-bine.3.2.5 expanded uncertainty, U, nquantity defining aninterval about the result of a measurement that may beexpected to encompass a large fraction of the di
13、stribution ofvalues that could reasonably be attributed to the measurand.1This guide is under the jurisdiction of ASTM Committee E20 on TemperatureMeasurement and is the direct responsibility of Subcommittee E20.03 on ResistanceThermometers.Current edition approved Dec. 1, 2007. Published January 20
14、08.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANS
15、I), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.5.1 DiscussionNormally, U is given at a coveragefactor of 2, approximating to a 95 % confidence interval.3.2.6 h
16、ysteresis, nproperty associated with the resistanceof a thermometer whereby the value of resistance at a tempera-ture is dependant upon previous exposure to different tempera-tures.3.2.7 normal distribution, na frequency distribution char-acterized by a bell shaped curve and defined by two param-ete
17、rs: mean and standard deviation.3.2.8 platinum resistance thermometer (PRT), na resis-tance thermometer with the resistance element constructedfrom platinum or platinum alloy.3.2.9 rectangular distribution, na frequency distributioncharacterized by a rectangular shaped curve and defined by twoparame
18、ters: mean and magnitude (semi-range).3.2.10 standard deviation of the mean, nan estimate of thestandard deviation of the sampling distribution of means, basedon the data from one or more random samples.3.2.10.1 DiscussionNumerically, it is equal to the stan-dard deviation obtained (s) when divided
19、by the square root ofthe size of the sample (n).Standard Deviation of the Mean 5s=n(1)3.2.10.2 standard platinum resistance thermometer (SPRT),na specialized platinum resistance thermometer constructedin such a way that it fulfills the requirements of the ITS-90.43.2.10.3 standard uncertainty, nunce
20、rtainty of the resultof a measurement expressed as a standard deviation, desig-nated as S.3.2.10.4 Type A evaluation (of uncertainty), nmethod ofevaluation of uncertainty by the statistical analysis of a seriesof observations.3.2.10.5 Type B evaluation (of uncertainty), nmethod ofevaluation of uncer
21、tainty by means other than statisticalanalysis of a series of observations.3.2.10.6 test uncertainty ratio (TUR), nthe ratio of thetolerance of the unit under test to the expanded calibrationuncertainty.3.2.10.7 uncertainty budget, nan analysis tool used forassembling and combining component uncerta
22、inties expectedin a measurement process into an overall expected uncertainty.3.2.10.8 unit under test (UUT), nthe platinum resistancethermometer to be calibrated.4. Summary of Guide4.1 The UUT is calibrated by determining the electricalresistance of its sensing element at one or more knowntemperatur
23、es covering the temperature range of interest. Theknown temperatures may be established by means of fixed-point systems or by using a reference thermometer. Either anSPRT or a PRT is recommended for use as the referencethermometer. However a liquid in glass (LIG) thermometer,thermistor, or thermocou
24、ple may be acceptable dependingupon the temperature of calibration, required accuracy, or otherconsiderations.4.2 The success of the calibration depends largely upon theability of the UUT to come to thermal equilibrium with thecalibration temperature of interest (fixed point cell or compari-son syst
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME25932007E1STANDARDGUIDEFORACCURACYVERIFICATIONOFINDUSTRIALPLATINUMRESISTANCETHERMOMETERS 工业 铂电阻

链接地址:http://www.mydoc123.com/p-531501.html