ASTM E2570-2007 Standard Test Methods for Evaluating Water-Resistive Barrier (WRB) Coatings Used under Exterior Insulation and Finish Systems (EIFS) or EIFS with Drainage《外部绝缘和精整系统.pdf
《ASTM E2570-2007 Standard Test Methods for Evaluating Water-Resistive Barrier (WRB) Coatings Used under Exterior Insulation and Finish Systems (EIFS) or EIFS with Drainage《外部绝缘和精整系统.pdf》由会员分享,可在线阅读,更多相关《ASTM E2570-2007 Standard Test Methods for Evaluating Water-Resistive Barrier (WRB) Coatings Used under Exterior Insulation and Finish Systems (EIFS) or EIFS with Drainage《外部绝缘和精整系统.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2570 07Standard Test Methods forEvaluating Water-Resistive Barrier (WRB) Coatings Usedunder Exterior Insulation and Finish Systems (EIFS) or EIFSwith Drainage1This standard is issued under the fixed designation E 2570; the number immediately following the designation indicates the yea
2、r oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods apply to trowel, roller, or sprayap
3、plied Water-resistive barrier (WRB) coatings that are appliedover exterior sheathing prior to application of EIFS or EIFSwith drainage wall claddings.1.2 Test methods for in place wall system and claddingrelated to tests such as fire resistance, wind load capability, airbarrier performance, and so f
4、orth. should also be consideredbut are outside the scope of this document.1.3 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its
5、use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 297/C 297M Test Method for Flatwise Tensile Strengthof Sandwich Constru
6、ctionsD 2247 Practice for Testing Water Resistance of Coatings in100 % Relative HumidityD 2898 Practice for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire TestingE72 Test Methods of Conducting Strength Tests of Panelsfor Building ConstructionE 96/E 96M Test Methods for Water Vapor Tr
7、ansmission ofMaterialsE 330 Test Method for Structural Performance of ExteriorWindows, Doors, Skylights and Curtain Walls by UniformStatic Air Pressure DifferenceE 331 Test Method for Water Penetration of Exterior Win-dows, Skylights, Doors, and Curtain Walls by UniformStatic Air Pressure Difference
8、E 631 Terminology of Building ConstructionsE 1233 Test Method for Structural Performance of ExteriorWindows, Doors, Skylights, and Curtain Walls by CyclicAir Pressure DifferentialE2110 Terminology for Exterior Insulation and Finish Sys-tems (EIFS)E 2134 Test Method for Evaluating the Tensile-Adhesio
9、nPerformance of an Exterior Insulation and Finish System(EIFS)E 2485 Test Method for Freeze/Thaw Resistance of Exte-rior Insulation and Finish Systems (EIFS) and WaterResistive Barrier Coatings2.2 AATCC Standards:3AATCC 127 Water Resistance: Hydrostatic Pressure Test3. Terminology3.1 Definitions rel
10、ated to EIFS may be found in Terminol-ogy E2110and general terms in Terminology E 631.4. Significance and Use4.1 This series of test methods provides a means to evaluateperformance of the water-resistive barrier coating when sub-jected to various physical and environmental conditions. Thewater-resis
11、tive barrier coating is applied between the EIFS andsubstrate in an EIFS-clad wall assembly and is intended toprovide additional protection to the building and its contentsfrom incidental moisture intrusion that may occur through thebuilding envelope. Although protected from direct weatherexposure a
12、fter the EIFS is installed, the coating must bedurable and weather resistant as it is subjected to variousenvironmental conditions prior to application of the EIFS aswell as while the system is in service.5. Test Specimens5.1 Tensile Bond1This test method is under the jurisdiction of ASTM Committee
13、E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.58on Exterior Insulation and Finish Systems (EIFS).Current edition approved Sept. 1, 2007. Published September 2007.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Servic
14、e at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American Association of Textile Chemists and Colorists(AATCC), P.O. Box 12215, Research Triangle Park, NC 27709, http:/www.aatcc.org.1Copyright A
15、STM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.1.1 Prepare five samples for each sheathing substrate, aminimum of 152 mm 3 152 mm (6 in. 3 6 in.), that consistsof two sheathing sections assembled with a 3.2 mm (18 in.)wide joint. Apply the jo
16、int treatment, if applicable, andwater-resistive barrier coating in accordance with the manu-facturers recommended instructions.5.1.2 Test where the water resistive barrier is a systemcomposed of multiple products that overlap, the bond betweenwater resistive barrier products.5.1.3 Prepare five spec
17、imens for each flashing material forwhich recognition is sought, a minimum of 51 mm 3 51 mm(2 in. 3 2 in.) by applying the water-resistive barrier coating,and the flashing treatment, to the flashing material.5.2 Freeze Thaw5.2.1 Construct five samples for each sheathing substrate, aminimum of 152 mm
18、 3 152 mm (6 in. 3 6 in.) that consistsof two sheathing sections assembled with a 3.2 mm (18 in.)wide joint. Apply the joint treatment, if applicable, and thewater-resistive barrier coating in accordance with the manu-facturers recommended instructions. The back and sides of thespecimens shall be se
19、aled with an impervious material thatneed not be the coating. Specimens shall be representative ofthose used in actual construction.5.3 Water Resistance5.3.1 Prepare three samples, a minimum of 102 mm 3 152mm (4 in. 3 6 in.), and containing a 6.4 mm (14 in.) wide jointfor each substrate by applying
20、the joint treatment, if applicable,and the water-resistive barrier coating to the substrate accord-ing to the manufacturers recommended application instruc-tions. The back and sides of the samples shall be sealed withmaterial impervious to water that need not be the waterresistive barrier coating. S
21、pecimens shall be representative ofthose used in actual construction.5.4 Water Vapor Transmission5.4.1 Prepare three samples, a minimum of 70 mm (234 in.)diameter of the water-resistive barrier coating by applying thewater-resistive barrier coating, at the recommended thickness,to a non-adhesive sur
22、face. After curing for the time recom-mended by the manufacturer, the coating is removed from thenon-adhesive surface and the average thickness is determinedfrom the material density, area, and weight or by using amicrometer or calipers to the nearest 0.025 mm (0.001 in.).5.5 Durability (Transverse
23、Load, Racking, EnvironmentalConditioning, and Water Penetration)5.5.1 Construct one sample, a minimum of 2438 mm 32438 mm (8 ft 3 8 ft) with either steel studs or 2 3 4 woodstuds spaced a minimum of 406 mm (16 in.) oc. Attach thesheathing substrate to the framing and include 3.2 mm (18 in.)wide vert
24、ical and horizontal substrate joints. Flashing shall alsobe included in the sample preparation to ensure that theinterface of the water-resistive barrier coating and flashing willnot be affected by various loading conditions. Apply the jointtreatments, if applicable, and water-resistive barrier coat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME25702007STANDARDTESTMETHODSFOREVALUATINGWATERRESISTIVEBARRIERWRBCOATINGSUSEDUNDEREXTERIORINSULATIONANDFINISHSYSTEMSEIFSOREIFSWITHDRAINAGE

链接地址:http://www.mydoc123.com/p-531440.html