《ASTM E2515-2009 Standard Test Method for Determination of Particulate Matter Emissions Collected by a Dilution tunnel《测定用稀释通道收集的粒状排放物的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2515-2009 Standard Test Method for Determination of Particulate Matter Emissions Collected by a Dilution tunnel《测定用稀释通道收集的粒状排放物的标准试验方法》.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2515 09Standard Test Method forDetermination of Particulate Matter Emissions Collected bya Dilution Tunnel1This standard is issued under the fixed designation E 2515; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, t
2、he year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is applicable for the determination ofparticulate matter emissions from solid-fuel-burning
3、 appli-ances including woodstoves, pellet-burning appliances,factory-built fireplaces, masonry fireplaces, masonry heaters,indoor furnaces, and indoor and outdoor hydronic heaterswithin a laboratory environment.1.2 Analytes will be a particulate matter (PM) with no CASnumber assigned. For data quali
4、ty objectives, see AppendixX1.1.3 The values stated in SI units are to be regarded asstandard. The values given in parentheses are mathematicalconversions to inch-pound units that are provided for informa-tion only and are not considered standard.1.4 This test method does not purport to address all
5、of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 2986 Practice for Ev
6、aluation of Air Assay Media by theMonodisperse DOP (Dioctyl Phthalate) Smoke Test3E 2558 Test Method for Determining Particulate MatterEmissions from Fires in Low Mass Wood-Burning Fire-placesE 2618 Test Method for Measurement of Particulate Emis-sions and Heating Efficiency of Outdoor Solid Fuel-Fi
7、redHydronic Heating Appliances2.2 AISI Documents:4AISI 316 Stainless Steel3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 laboratory environmentthe area or room that is usedfor the storage, weighing, assembly, disassembly, and desicca-tion of filters and related equipment (sam
8、ple recovery andanalysis).3.1.2 particulate matter (PM)all gas-borne matter result-ing from combustion of solid fuel, as specified in the applianceoperation test method, that is collected and retained by thespecified filter and probe system under the conditions of thetest.3.1.3 test facilitythe area
9、 in which the tested appliance isinstalled, operated, and sampled for emissions.4. Summary of Test Method4.1 The total flue-gas exhaust from a solid fuel burningappliance is collected along with ambient dilution air with acollection hood. Duplicate sampling trains are used to extractgas samples from
10、 the dilution tunnel for determination ofparticulate matter concentrations. Each sample train has twoglass fiber filters in series. The samples are withdrawn at aconsistently proportional rate from sampling points located atthe centroid of a sampling tunnel. During sampling, the filtersare maintaine
11、d at a temperature less than 32C (90F). Themass of the sampled particulate matter is determined gravi-metrically after the removal of uncombined water. The totalparticulate matter mass collected on the filters and in the probeand front filter housing are multiplied by the ratio of thedilution tunnel
12、 flow to sample flow to determine the totalparticulate emissions during a test.4.2 The sampling system for this test method consists ofduplicate dual-filter dry sampling trains. Both of the particulatesampling trains are operated simultaneously at a sample flowrate not to exceed 0.007 m3/min (0.25 c
13、fm/min). The totalparticulate results obtained from the two sampling trains are1This test method is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.54on Solid Fuel Burning Appliances.Current edition approved May 1, 2009. Pu
14、blished June 2009. Originallyapproved in 2007. Last previous edition approved in 2007 as E 2515 07.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Doc
15、ument Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.4Available from American Iron and Steel Institute (AISI), 1140 ConnecticutAve., NW, Suite 705, Washington, DC 20036, http:/www.steel.org.1Copyright ASTM International,
16、 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.averaged to determine the particulate emissions and are com-pared as a quality control check on the data validity.4.3 The particulate concentration results for each samplingtrain is adjusted by the particulate conce
17、ntration result from asingle ambient air sample blank collected and processed thesame as the dilution tunnel particulate sampling trains de-scribed in Section 4.2, except that only one filter is used in thesampling train. The ambient air sample probe shall be located2 m (6.6 ft) below the dilution t
18、unnel collection hood and 1 m(3.3 ft) from the chimney centerline. A metering system asdescribed in 6.1.1.4 shall be used to determine the volume ofambient air collected. The sample flow rate shall be in therange 0.004 to 0.008 m3/min (0.15 to 0.25 cfm).4.4 Appliances tested by this test method are
19、to be fueledand operated as specified in appliance-specific test methodssuch as, but not limited to, Test Methods E 2558 or E 2618.5. Safety5.1 DisclaimerThis test method may involve hazardousmaterials, operations, and equipment. This test method may notaddress all of the safety problems associated
20、with its use. It isthe responsibility of the user of this test method to establishappropriate safety and health practices and to determine theapplicability of regulatory limitations prior to performing thistest method.6. Equipment and Supplies6.1 Sample CollectionThe following equipment is re-quired
21、 for sample collection:6.1.1 Particulate Sampling TrainTwo separate, completeparticulate sampling trains (also referred to as “samplingtrains”) are required for each test run. The filter face velocityshall not exceed 150 mm/sec (30 ft/min) during the test run.The dry gas meter shall be calibrated fo
22、r the same flow raterange as encountered during the test runs. The sampling trainconfiguration is shown in Fig. 1 and consists of the followingcomponents.6.1.1.1 Filter Holder AssemblyThe filter holder assemblyis shown in Fig. 2 and consists of the following components:(1) Filter HoldersThe primary
23、(front) filter holder shallbe aluminum or PTFE.5The backup (rear) filter holder may bemade of materials such as polycarbonate.6With such plasticmaterials, it is recommended not to use solvents when cleaningthe filter holder parts. Mild soap and distilled water can be usedfor cleaning plastic filter
24、holder parts. The two filter holdersshall be placed in series with the backup filter holder located 25to 100 mm (1 to 4 in.) downstream from the primary filterholder. The filter holders shall be capable of holding a filterwith 47 mm diameter. The holder design shall provide apositive seal against le
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME25152009STANDARDTESTMETHODFORDETERMINATIONOFPARTICULATEMATTEREMISSIONSCOLLECTEDBYADILUTIONTUNNEL

链接地址:http://www.mydoc123.com/p-531290.html