《ASTM E2485 E2485M-2013 Standard Test Method for Freeze Thaw Resistance of Exterior Insulation and Finish Systems (EIFS) and Water Resistive Barrier Coatings《外部绝缘和饰面系统(EIFS)以及防水阻隔涂层.pdf》由会员分享,可在线阅读,更多相关《ASTM E2485 E2485M-2013 Standard Test Method for Freeze Thaw Resistance of Exterior Insulation and Finish Systems (EIFS) and Water Resistive Barrier Coatings《外部绝缘和饰面系统(EIFS)以及防水阻隔涂层.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2485 06E2485/E2485M 13Standard Test Method forFreeze/Thaw Resistance of Exterior Insulation and FinishSystems (EIFS) and Water Resistive Barrier Coatings1This standard is issued under the fixed designation E2485;E2485/E2485M; the number immediately following the designation indicatesth
2、e year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers procedures for determinin
3、g the effect of freezing and thawing of exterior insulation and finishsystems (EIFS), an EIFS with water-resistive barrier coatings, and water-resistive barrier coatings by itself.1.2 The values stated in either SI units or inch-pound units are to be regarded separately as the standard. The values g
4、iven inparentheses are for information purposes only.stated in each system may not be exact equivalents; therefore, each system shall beused independently of the other. Combining values from the two systems may result in non-conformance with the standard.1.3 This standard does not purport to address
5、 all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E631 Terminology
6、 of Building ConstructionsE2110 Terminology for Exterior Insulation and Finish Systems (EIFS)3. Terminology3.1 For definitions and terms relating to this standard, see Terminologiesgeneral terminology regarding EIFS and building ingeneral, see Terminology E2110 (for EIFS terms) and Terminology E631
7、and(for E2110.buildings in general).4. Summary of Test Method4.1 Specimens are subjected to cycles of freezing and thawing. Surface changes, viewed at 5 magnification, are examined forsigns of deleterious effects, such as cracking, crazing, checking, blistering, peeling, delamination, or erosion.5.
8、Significance and Use5.1 Resistance to freezing and thawing is a factor when determining the durability of EIFS, an EIFS with water-resistive barriercoatings, and water-resistive barrier coatings by itself.6. Apparatus6.1 Compressor, Freezing Chamber, and CirculatorOf such design and capacity that th
9、e temperature of the air in the freezingchamber shall not exceed 9C (16F) one hour16F 1 h after introducing the maximum charge of units. The initial temperaturewill not exceed 32C (90F).90F.6.2 Trays and ContainersWill be shallow, metal, and have an inside depth of 38.1 6 12.7 mm (1 112 6 12 in.)in.
10、 and beof suitable strength and size so that the tray with a charge of frozen units can be removed from the freezing chamber by one person.6.3 Thawing TankShould permit complete submersion of the specimens in their trays. Adequate means shall be provided sothat the water in the tank may be kept at a
11、 temperature of 24 6 5.5 C (75 6 10F).5.5C 75 6 10F.1 This test method is under the jurisdiction of ASTM Committee E06 on Performance of Buildings and is the direct responsibility of Subcommittee E06.58 on ExteriorInsulation and Finish Systems (EIFS).Current edition approved April 1, 2006Sept. 1, 20
12、13. Published April 2006September 2013. Originally approved in 2006. Last previous edition approved in 2006 as E2485 06. DOI: 10.1520/E2485-06.10.1520/E2485_E2485M-13.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual B
13、ook of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be tech
14、nically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO
15、Box C700, West Conshohocken, PA 19428-2959. United States16.4 Drying RoomMaintained at a temperature of 24 6 8C (75 615F), 75 6 15F, with a relative humidity between 30and 70 percent. 70 %. The drying room should be free from drafts.7. Test Specimens7.1 Water-Resistive Barrier Coatings7.1.1 Prepare
16、a minimum of five test specimens measuring a minimum of 150 mm2 (6 6 in.2) for each substrate that will beevaluated.7.1.2 For sheathing substrates, two sheathing sections shall be assembled with a 3.2-mm (18-in.)-in. joint. The joint shall betreated as it would in its end-use configuration.7.1.3 App
17、ly the water-resistive barrier coating over the substrate surface in accordance with the manufacturers instructions. Thespecimen shall be representative of those used in actual construction. Allow the water-resistive barrier coating to dry a minimumof 24 hours.h.7.1.4 The back and sides of the test
18、specimens shall be sealed with an impervious material that need not be the coating.7.2 EIFS Testing7.2.1 Prepare a minimum of five test specimens measuring a minimum of 150 mm2 (6 6 in.2) and consisting of the followingmaterials:7.2.1.1 Substrate,7.2.1.2 Water-resistive barrier coating (if applicabl
19、e),7.2.1.3 Insulation board,7.2.1.4 Reinforcing mesh, and7.2.1.5 Finish.7.2.2 If a water-resistive barrier coating is included as part of the EIFS System, apply the water-resistive barrier coating overthe substrate surface in accordance with the manufacturers instructions. The specimen shall be repr
20、esentative of those used inactual construction.7.2.3 Secure the insulation board to the substrate or water-resistive barrier coating (where applicable). Apply the base coat andreinforcing mesh to the surface of the insulation board including the edges. Allow the base coat to cure a minimum of 24 hou
21、rs.h.7.2.4 The back and sides of the test specimens shall be sealed with an impervious material that need not be the water-resistivebarrier coating.8. Conditioning8.1 Allow the test specimens to cure a minimum of 28 days at room temperature of 22 6 3C (7272 6 5F)5F and 50 65 % relative humidity.9. P
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME2485E2485M2013STANDARDTESTMETHODFORFREEZETHAWRESISTANCEOFEXTERIORINSULATIONANDFINISHSYSTEMSEIFSANDWATERRESISTIVEBARRIERCOATINGS

链接地址:http://www.mydoc123.com/p-531232.html