《ASTM E2466-2006(2011) Standard Test Method for Colorimetry of Teeth Using Digital Still Camera Technology《用数字照相机技术测试牙齿比色法的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2466-2006(2011) Standard Test Method for Colorimetry of Teeth Using Digital Still Camera Technology《用数字照相机技术测试牙齿比色法的标准试验方法》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2466 06 (Reapproved 2011)Standard Test Method forColorimetry of Teeth Using Digital Still Camera Technology1This standard is issued under the fixed designation E2466; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, th
2、e year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONTooth color is an important parameter used to ascertain certain medical and esthetic information.CIE colorim
3、etric values for the teeth are derived from the native RGB signals generated by a digitalstill camera, DSC, by broadband measurement of the reflectance of teeth. The illumination angle is 45degrees and CIELAB colorimetric coordinates are computed using equations contained in PracticeE308. This test
4、method, E2466, specifies the procedure used for the measurement of tooth colorin-vivo and in-vitro with illumination at 45 degrees relative to the sample plane which is also thenormal of the mouth, under an approximate equal energy spectrum. This test method is appropriate foranterior and posterior
5、teeth.1. Scope1.1 This test method covers the procedure, instrumentalrequirements, standardization procedures, material standards,measurement procedures, and parameters necessary to makeprecise measurements of in-vivo tooth color and tooth white-ness. In particular it is meant to measure the color o
6、f teeth inselected human subjects.1.2 Digital images are used to evaluate tooth color of bothposterior and anterior dentition (teeth). All other non-relevantparts, such as gums, spaces, etc., must be separated from themeasurement and the analysis.All localized discoloration; suchas stains, inclusion
7、s, etc., may be separated from the measure-ment and the analysis.1.3 The broadband reflectance factors of teeth are measured.The colorimetric measurement is performed with a digital stillcamera while using an illuminator(s) that provides controlledillumination on the teeth. The measured data from a
8、digitalimage are captured using a DSC. This test method is particu-larly useful for the gamut of tooth color which is:1.3.1 CIE L* from 55 to 95,1.3.2 CIE a* from 3 to 12,1.3.3 CIE b* from 8 to 25 units.1.4 The wavelengths for this test method include thatportion of the visible spectrum from 400 to
9、700 nm.1.5 Data acquired using this test method is for comparativepurposes used during clinical trials or other types of research.1.6 This test method is designed to encompass natural teeth,artificial teeth, restorations, and shade guides.NOTE 1This procedure may not be applicable for all types of d
10、entalwork.1.7 The apparatus, measurement procedure, data analysistechnique are generic, so that a specific apparatus, measure-ment procedure, or data analysis technique may not be ex-cluded.1.8 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for i
11、nformationonly.1.9 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and to determine theapplicability of regulatory limitations prior to use
12、.2. Referenced Documents2.1 ASTM Standards:2D2244 Practice for Calculation of Color Tolerances andColor Differences from Instrumentally Measured ColorCoordinatesE179 Guide for Selection of Geometric Conditions forMeasurement of Reflection and Transmission Properties ofMaterialsE284 Terminology of Ap
13、pearanceE308 Practice for Computing the Colors of Objects by1This test method is under the jurisdiction of ASTM Committee E12 on Colorand Appearance and is the direct responsibility of Subcommittee E12.06 on ImageBased Color Measurement.Current edition approved June 1, 2011. Published June 2011. Ori
14、ginallyapproved in 2006. Last previous edition approved in 2006 as E2466 - 06. DOI:10.1520/E2466-06R11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards
15、 Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Using the CIE SystemE313 Practice for Calculating Yellowness and WhitenessIndices from Instrumentally Measured Color CoordinatesE1345 Practice
16、for Reducing the Effect of Variability ofColor Measurement by Use of Multiple MeasurementsE1767 Practice for Specifying the Geometries of Observa-tion and Measurement to Characterize the Appearance ofMaterials2.2 ISO Publications:3ISO 17321-1, Colour characterization of digital still cam-eras (DSCs)
17、 Part 1: Stimuli, metrology, and test proce-dures2.3 ISCC Publications:4Technical Report 2003-1 Guide to Material Standards andTheir Use in Color Measurement3. Terminology3.1 Terms and definitions in Terminology E284 are appli-cable to this test method.3.2 DefinitionsTerms included in this section a
18、re peculiarto this standard.3.2.1 angle of incidence, nu1and optional u2, the polarangle between the central ray of the illuminator(s), I1and I2,and the Z axis which is normal to the camera. See Fig. A1.1.3.2.2 anterior teeth, nanterior teeth are the six upper andsix lower front teeth; the anterior
19、teeth consist of incisors andcuspids (canines).3.2.3 bit depth, nthe number of digital bits used to storeinformation contained in each pixel.3.2.3.1 DiscussionThe higher the depth, the more colorsare in an image. With 8 bit-per-channel color, there are a totalof 256 bits available for color represen
20、tation in each of the R,G, B channels. RGB 8 bit-per-channel color is sometimescalled “24 bit color.”3.2.4 canine, nthe third tooth from the center of themouth towards the back of the mouth; these are the front teeththat have one rounded or pointed edge used for biting.3.2.5 facial surfaces, nof or
21、toward the face, used todesignate the side of the tooth that is facing away from thetongue side.3.2.6 in-vitro, adj or advin an artificial environmentoutside of the human body.3.2.7 in-vivo, adj or advwithin a living body; that is,measurements made of a living tooth in a living body.3.2.8 maxillary
22、anterior teeth, nthe four front upperincisors and the canine teeth. See Fig. A1.5.3.2.9 native digital still camera spectral response function,nthe function relating scene radiance to image intensity of animaging system is called the digital still camera spectralresponse function.3.2.10 polarization
23、, nthe orientation of the vibration pat-tern of light waves in a singular plane.3.2.11 polarizer filter, na component that blocks one ofthe two planes of vibration of an electromagnetic wave,producing linearly polarized light.3.2.11.1 DiscussionA polarizing filter can be used insunglasses to reduce
24、glare.3.2.12 posterior teeth, nposterior teeth are the large teethin the back of the mouth.3.2.13 spatial whitening response, nthe evaluation ofcolor or color change used to determine unit dosing.4. Summary of Test Method4.1 This test method describes the procedures for broadbandreflectance measurem
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME246620062011STANDARDTESTMETHODFORCOLORIMETRYOFTEETHUSINGDIGITALSTILLCAMERATECHNOLOGY 数字 照相机 技术 测试

链接地址:http://www.mydoc123.com/p-531186.html