ASTM E2466-2006 Standard Test Method for Colorimetry of Teeth Using Digital Still Camera Technology《利用数字静态摄影机实现牙齿比色法的标准试验方法》.pdf
《ASTM E2466-2006 Standard Test Method for Colorimetry of Teeth Using Digital Still Camera Technology《利用数字静态摄影机实现牙齿比色法的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2466-2006 Standard Test Method for Colorimetry of Teeth Using Digital Still Camera Technology《利用数字静态摄影机实现牙齿比色法的标准试验方法》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2466 06Standard Test Method forColorimetry of Teeth Using Digital Still Camera Technology1This standard is issued under the fixed designation E 2466; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last r
2、evision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.INTRODUCTIONTooth color is an important parameter used to ascertain certain medical and esthetic information.CIE colorimetric values fo
3、r the teeth are derived from the native RGB signals generated by a digitalstill camera, DSC, by broadband measurement of the reflectance of teeth. The illumination angle is 45degrees and CIELAB colorimetric coordinates are computed using equations contained in PracticeE 308. This test method, E 2466
4、, specifies the procedure used for the measurement of tooth colorin-vivo and in-vitro with illumination at 45 degrees relative to the sample plane which is also thenormal of the mouth, under an approximate equal energy spectrum. This test method is appropriate foranterior and posterior teeth.1. Scop
5、e1.1 This test method covers the procedure, instrumentalrequirements, standardization procedures, material standards,measurement procedures, and parameters necessary to makeprecise measurements of in-vivo tooth color and tooth white-ness. In particular it is meant to measure the color of teeth insel
6、ected human subjects.1.2 Digital images are used to evaluate tooth color of bothposterior and anterior dentition (teeth). All other non-relevantparts, such as gums, spaces, etc., must be separated from themeasurement and the analysis.All localized discoloration; suchas stains, inclusions, etc., may
7、be separated from the measure-ment and the analysis.1.3 The broadband reflectance factors of teeth are measured.The colorimetric measurement is performed with a digital stillcamera while using an illuminator(s) that provides controlledillumination on the teeth. The measured data from a digitalimage
8、are captured using a DSC. This test method is particu-larly useful for the gamut of tooth color which is:1.3.1 CIE L* from 55 to 95,1.3.2 CIE a* from 3 to 12,1.3.3 CIE b* from 8 to 25 units.1.4 The wavelengths for this test method include thatportion of the visible spectrum from 400 to 700 nm.1.5 Da
9、ta acquired using this test method is for comparativepurposes used during clinical trials or other types of research.1.6 This test method is designed to encompass natural teeth,artificial teeth, restorations, and shade guides.NOTE 1This procedure may not be applicable for all types of dentalwork.1.7
10、 The apparatus, measurement procedure, data analysistechnique are generic, so that a specific apparatus, measure-ment procedure, or data analysis technique may not be ex-cluded.1.8 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonl
11、y.1.9 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and to determine theapplicability of regulatory limitations prior to use.2. Reference
12、d Documents2.1 ASTM Standards:2D 2244 Practice for Calculation of Color Tolerances andColor Differences from Instrumentally Measured ColorCoordinatesE 179 Guide for Selection of Geometric Conditions forMeasurement of Reflection and Transmission Properties ofMaterialsE 284 Terminology of AppearanceE
13、308 Practice for Computing the Colors of Objects byUsing the CIE SystemE 313 Practice for Calculating Yellowness and WhitenessIndices from Instrumentally Measured Color Coordinates1This test method is under the jurisdiction of ASTM Committee E12 on Colorand Appearance and is the direct responsibilit
14、y of Subcommittee E12.06 on ImageBased Color Measurement.Current edition approved Jan. 15, 2006. Published March 2006.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer t
15、o the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.E 1345 Practice for Reducing the Effect of Variability ofColor Measurement by Use of Multiple MeasurementsE 1767 Practice for Sp
16、ecifying the Geometries of Observa-tion and Measurement to Characterize the Appearance ofMaterials2.2 ISO Publications:3ISO 17321-1, Colour characterization of digital still cam-eras (DSCs) Part 1: Stimuli, metrology, and test proce-dures2.3 ISCC Publications:4Technical Report 2003-1 Guide to Materi
17、al Standards andTheir Use in Color Measurement3. Terminology3.1 Terms and definitions in Terminology E 284 are appli-cable to this test method.3.2 DefinitionsTerms included in this section are peculiarto this standard.3.2.1 angle of incidence, nu1and optional u2, the polarangle between the central r
18、ay of the illuminator(s), I1and I2,and the Z axis which is normal to the camera. See Fig. A1.1.3.2.2 anterior teeth, nanterior teeth are the six upper andsix lower front teeth; the anterior teeth consist of incisors andcuspids (canines).3.2.3 bit depth, nthe number of digital bits used to storeinfor
19、mation contained in each pixel.3.2.3.1 DiscussionThe higher the depth, the more colorsare in an image. With 8 bit-per-channel color, there are a totalof 256 bits available for color representation in each of the R,G, B channels. RGB 8 bit-per-channel color is sometimescalled “24 bit color.”3.2.4 can
20、ine, nthe third tooth from the center of themouth towards the back of the mouth; these are the front teeththat have one rounded or pointed edge used for biting.3.2.5 facial surfaces, nof or toward the face, used todesignate the side of the tooth that is facing away from thetongue side.3.2.6 in-vitro
21、, adj or advin an artificial environmentoutside of the human body.3.2.7 in-vivo, adj or advwithin a living body; that is,measurements made of a living tooth in a living body.3.2.8 maxillary anterior teeth, nthe four front upperincisors and the canine teeth. See Fig. A1.5.3.2.9 native digital still c
22、amera spectral response function,nthe function relating scene radiance to image intensity of animaging system is called the digital still camera spectralresponse function.3.2.10 polarization, nthe orientation of the vibration pat-tern of light waves in a singular plane.3.2.11 polarizer filter, na co
23、mponent that blocks one ofthe two planes of vibration of an electromagnetic wave,producing linearly polarized light.3.2.11.1 DiscussionA polarizing filter can be used insunglasses to reduce glare.3.2.12 posterior teeth, nposterior teeth are the large teethin the back of the mouth.3.2.13 spatial whit
24、ening response, nthe evaluation ofcolor or color change used to determine unit dosing.4. Summary of Test Method4.1 This test method describes the procedures for broadbandreflectance measurement of teeth, in-vivo and in-vitro. Thestandardization of the instrumentation used to measure asubjects teeth
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME24662006STANDARDTESTMETHODFORCOLORIMETRYOFTEETHUSINGDIGITALSTILLCAMERATECHNOLOGY 利用 数字 静态 摄影机 实现

链接地址:http://www.mydoc123.com/p-531185.html