ASTM E2451-2013 Standard Practice for Preserving Ignitable Liquids and Ignitable Liquid Residue Extracts from Fire Debris Samples《对燃烧残骸试样中可燃性液体和可燃性液体残留物提取物进行保存的标准实施规程》.pdf
《ASTM E2451-2013 Standard Practice for Preserving Ignitable Liquids and Ignitable Liquid Residue Extracts from Fire Debris Samples《对燃烧残骸试样中可燃性液体和可燃性液体残留物提取物进行保存的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2451-2013 Standard Practice for Preserving Ignitable Liquids and Ignitable Liquid Residue Extracts from Fire Debris Samples《对燃烧残骸试样中可燃性液体和可燃性液体残留物提取物进行保存的标准实施规程》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2451 13Standard Practice forPreserving Ignitable Liquids and Ignitable Liquid ResidueExtracts from Fire Debris Samples1This standard is issued under the fixed designation E2451; the number immediately following the designation indicates the year oforiginal adoption or, in the case of r
2、evision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice describes procedures for preserving resi-dues of ignitable liquids in extracts obta
3、ined from fire debrissamples and questioned ignitable liquid samples. Extractionprocedures are described in the Referenced Documents.1.2 This practice does not attempt to address all the issuesregarding the short-term or long-term storage of ignitableliquid samples and ignitable liquid extracts from
4、 fire debrissamples. The changes that may occur under various storageconditions have not been fully documented.1.3 This practice cannot replace knowledge, skill, or abilityacquired through appropriate education, training, and experi-ence and should be used in conjunction with sound profes-sional jud
5、gment.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Refere
6、nced Documents2.1 ASTM Standards:2E1386 Practice for Separation of Ignitable Liquid Residuesfrom Fire Debris Samples by Solvent ExtractionE1388 Practice for Sampling of Headspace Vapors from FireDebris SamplesE1412 Practice for Separation of Ignitable Liquid Residuesfrom Fire Debris Samples by Passi
7、ve Headspace Concen-tration With Activated CharcoalE1413 Practice for Separation and Concentration of Ignit-able Liquid Residues from Fire Debris Samples by Dy-namic Headspace ConcentrationE1459 Guide for Physical Evidence Labeling and RelatedDocumentationE1492 Practice for Receiving, Documenting, S
8、toring, andRetrieving Evidence in a Forensic Science LaboratoryE1618 Test Method for Ignitable Liquid Residues in Extractsfrom Fire Debris Samples by Gas Chromatography-MassSpectrometryE2154 Practice for Separation and Concentration of Ignit-able Liquid Residues from Fire Debris Samples by Pas-sive
9、Headspace Concentration with Solid Phase Microex-traction (SPME)3. Summary of Practice3.1 Extracts obtained from fire debris samples and ques-tioned liquids analyzed for the presence of ignitable liquidresidues are retained and preserved for potential reanalysis byTest Method E1618.4. Significance a
10、nd Use4.1 The archiving of extracts recovered from fire debris orliquids submitted in a fire investigation provides a mechanismto preserve extracts and liquids for reanalysis in the event thatsample loss, sample degradation, or failure of the fire debriscontainer occurs during post-analysis storage
11、of fire debrisevidence.4.2 The nature of some extraction procedures, which maypreclude reanalysis, is considered.4.3 Changes to a preserved sample extract and the length oftime it remains viable under storage conditions are unknown.4.4 The concentration and composition of the ignitableliquid residue
12、 or the use of an alternate extraction/concentration technique used to preserve a sample extract ofthe fire debris sample may result in different findings betweenthe analysis of the preserved sample and the original analysis.5. Materials5.1 Airtight and Vapor-Tight, Volatile-Free StorageContainersTh
13、e following are suggested container types:5.1.1 Septum crimp vials with PTFE-lined seals.5.1.2 Screw cap glass vials with PTFE-lined seals.5.1.3 Polymer evidence bags (this does not include polyeth-ylene or polypropylene-type containers).1This practice is under the jurisdiction of ASTM Committee E30
14、 on ForensicSciences and is the direct responsibility of Subcommittee E30.01 on Criminalistics.Current edition approved June 1, 2013. Published July 2013. Originally approvedin 2008. Last previous edition approved in 2008 as E2451 08. DOI: 10.1520/E2451-13.2For referenced ASTM standards, visit the A
15、STM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. Unit
16、ed States15.2 Adsorption Media:5.2.1 Activated charcoal (coconut).5.2.2 Activated charcoal strips.6. Procedure6.1 Passive Headspace Concentration with Activated Char-coal (Practice E1412).6.1.1 Single-Strip Adsorption:6.1.1.1 After analysis, the eluted and analyzed extract maybe retained for preserv
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME24512013STANDARDPRACTICEFORPRESERVINGIGNITABLELIQUIDSANDIGNITABLELIQUIDRESIDUEEXTRACTSFROMFIREDEBRISSAMPLES

链接地址:http://www.mydoc123.com/p-531153.html