ASTM E2371-2013 Standard Test Method for Analysis of Titanium and Titanium Alloys by Direct Current Plasma and Inductively Coupled Plasma Atomic Emission Spectrometry (Performance-.pdf
《ASTM E2371-2013 Standard Test Method for Analysis of Titanium and Titanium Alloys by Direct Current Plasma and Inductively Coupled Plasma Atomic Emission Spectrometry (Performance-.pdf》由会员分享,可在线阅读,更多相关《ASTM E2371-2013 Standard Test Method for Analysis of Titanium and Titanium Alloys by Direct Current Plasma and Inductively Coupled Plasma Atomic Emission Spectrometry (Performance-.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2371 13Standard Test Method forAnalysis of Titanium and Titanium Alloys by Direct CurrentPlasma and Inductively Coupled Plasma Atomic EmissionSpectrometry (Performance-Based Test Methodology)1This standard is issued under the fixed designation E2371; the number immediately following th
2、e designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This method describes th
3、e analysis of titanium andtitanium alloys, such as specified by committee B10, byinductively coupled plasma atomic emission spectrometry(ICP-AES) and direct current plasma atomic emission spec-trometry (DCP-AES) for the following elements:ElementApplicationRange (wt.%)QuantitativeRange (wt.%)Aluminu
4、m 08 0.009 to 8.0Boron 00.04 0.0008 to 0.01Cobalt 0-1 0.006 to 0.1Chromium 05 0.005 to 4.0Copper 00.6 0.004 to 0.5Iron 03 0.004 to 3.0Manganese 00.04 0.003 to 0.01Molybdenum 08 0.004 to 6.0Nickel 01 0.001 to 1.0Niobium 0-6 0.008 to 0.1Palladium 0-0.3 0.02 to 0.20Ruthenium 0-0.5 0.004 to 0.10Silicon
5、00.5 0.02 to 0.4Tantalum 0-1 0.01 to 0.10Tin 04 0.02 to 3.0Tungsten 0-5 0.01 to -0.10Vanadium 015 0.01 to 15.0Yttrium 00.04 0.001 to 0.004Zirconium 05 0.003 to 4.01.2 This test method has been interlaboratory tested for theelements and ranges specified in the quantitative range part ofthe table abov
6、e. It may be possible to extend this test methodto other elements or broader mass fraction ranges as shown inthe application range part of the table above provided that testmethod validation is performed that includes evaluation ofmethod sensitivity, precision, and bias. Additionally, the vali-datio
7、n study shall evaluate the acceptability of sample prepa-ration methodology using reference materials or spike recov-eries or both. Guide E2857 provides information on validationof analytical methods for alloy analysis.1.3 Because of the lack of certified reference materials(CRMs) containing bismuth
8、, hafnium, and magnesium, theseelements were not included in the scope or the interlaboratorystudy (ILS). It may be possible to extend the scope of this testmethod to include these elements provided that method vali-dation includes the evaluation of method sensitivity, precision,and bias during the
9、development of the testing method.1.4 UnitsThe values stated in SI units are to be regardedas the standard. No other units of measurement are included inthis standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of
10、the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific safetyhazards statements are given in Section 9.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterE50 Practi
11、ces for Apparatus, Reagents, and Safety Consid-erations for Chemical Analysis of Metals, Ores, andRelated MaterialsE135 Terminology Relating to Analytical Chemistry forMetals, Ores, and Related MaterialsE1097 Guide for Determination of Various Elements byDirect Current Plasma Atomic Emission Spectro
12、metryE1329 Practice for Verification and Use of Control Charts inSpectrochemical AnalysisE1479 Practice for Describing and Specifying Inductively-Coupled Plasma Atomic Emission SpectrometersE1601 Practice for Conducting an Interlaboratory Study toEvaluate the Performance of an Analytical MethodE1763
13、 Guide for Interpretation and Use of Results fromInterlaboratory Testing of Chemical Analysis Methods1This test method is under the jurisdiction of ASTM Committee E01 onAnalytical Chemistry for Metals, Ores, and Related Materials and is the directresponsibility of Subcommittee E01.06 on Ti, Zr, W, M
14、o, Ta, Nb, Hf, Re.Current edition approved June 15, 2013. Published June 2013. Originallyapproved in 2004. Last previous edition approved in 2004 as E2371 - 04, which waswithdrawn in January 2013 and reinstated in June 2013. DOI: 10.1520/E2371-13.2For referenced ASTM standards, visit the ASTM websit
15、e, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1
16、E1832 Practice for Describing and Specifying a DirectCurrent Plasma Atomic Emission SpectrometerE2027 Practice for Conducting Proficiency Tests in theChemical Analysis of Metals, Ores, and Related MaterialsE2626 Guide for Spectrometric Analysis of Reactive andRefractory MetalsE2857 Guide for Validat
17、ing Analytical Methods2.2 ISO Standards:3ISO/IEC 17025 Requirements for the Competence of Cali-bration and Test LaboratoriesISO Guide 31 Reference MaterialsContents of Certificatesand LabelsISO Guide 34 General Requirements for the Competence ofReference Material ProducersISO Guide 98-3 Uncertainty
18、of measurement Part 3: Guideto the Expression of Uncertainty in Measurement (GUM:1995)First Edition3. Terminology3.1 For definitions of terms used in this test method, refer toTerminology E135.4. Summary of Test Method4.1 Amineral acid solution of the sample is aspirated into aninductively coupled p
19、lasma (ICP) or direct current plasma(DCP) spectrometer. The intensities of emission lines from thespectra of the analytes are measured and compared withcalibration curves obtained from solutions containing knownamounts of pure elements.5. Significance and Use5.1 This test method for the chemical ana
20、lysis of titaniumand titanium alloys is primarily intended to test material forcompliance with specifications of chemical composition suchas those under the jurisdiction of ASTM Committee B10. Itmay also be used to test compliance with other specificationsthat are compatible with the test method.5.2
21、 It is assumed that all who use this test method will betrained analysts capable of performing common laboratoryprocedures skillfully and safely and that the work will beperformed in a properly equipped laboratory.5.3 This is a performance-based test method that relies moreon the demonstrated qualit
22、y of the test result than on strictadherence to specific procedural steps. It is expected thatlaboratories using this test method will prepare their own workinstructions. These work instructions will include detailedoperating instructions for the specific laboratory, the specificreference materials
23、used, and performance acceptance criteria.It is also expected that, when applicable, each laboratory willparticipate in proficiency test programs, such as described inPractice E2027, and that the results from the participatinglaboratory will be satisfactory.6. Interferences6.1 In Practice E1479, the
24、 typical interferences encounteredduring inductively coupled plasma spectrometric analysis ofmetal alloys are described. In Guide E1097, the typicalinterferences encountered during direct current plasma emis-sion spectrometric analysis of metal alloys are described. Theuser is responsible for ensuri
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME23712013STANDARDTESTMETHODFORANALYSISOFTITANIUMANDTITANIUMALLOYSBYDIRECTCURRENTPLASMAANDINDUCTIVELYCOUPLEDPLASMAATOMICEMISSIONSPECTROMETRYPERFORMANCEPDF

链接地址:http://www.mydoc123.com/p-530994.html