ASTM E2319-2004(2011) Standard Test Method for Determining Air Flow Through the Face and Sides of Exterior Windows Curtain Walls and Doors Under Specified Pressure Differences Acro.pdf
《ASTM E2319-2004(2011) Standard Test Method for Determining Air Flow Through the Face and Sides of Exterior Windows Curtain Walls and Doors Under Specified Pressure Differences Acro.pdf》由会员分享,可在线阅读,更多相关《ASTM E2319-2004(2011) Standard Test Method for Determining Air Flow Through the Face and Sides of Exterior Windows Curtain Walls and Doors Under Specified Pressure Differences Acro.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2319 04 (Reapproved 2011)Standard Test Method forDetermining Air Flow Through the Face and Sides ofExterior Windows, Curtain Walls, and Doors Under SpecifiedPressure Differences Across the Specimen1This standard is issued under the fixed designation E2319; the number immediately follow
2、ing the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method i
3、s a modified version of Test MethodE283, and provides a standard laboratory procedure for deter-mining air leakage separately through the face and sides ofexterior windows, curtain walls, and doors under specifieddifferential pressure conditions across the specimen. The testmethod described is for t
4、ests with constant temperature andhumidity across the specimen.NOTE 1Detailing buildings with continuous air barriers requires thatthe air barrier plane in a window system be clearly defined. When specialcircumstances dictate that the air barrier be sealed to the window frame ata location other than
5、 that used to seal the specimen to the test chamber inthis test method, additional laboratory testing may be required to clarifypotential paths of air flow through the sides of the window frame. Theadapted testing procedure described herein is intended for this purpose.1.2 This laboratory procedure
6、is applicable to exteriorwindows, curtain walls, and doors and is intended to measureonly such leakage associated with the assembly and not theinstallation. The test method can be adapted for the latterpurpose.NOTE 2Performing tests at non-ambient conditions or with a tem-perature differential acros
7、s the specimen may affect the air leakage rate.This is not addressed by this test method.1.3 This test method is intended for laboratory use. Personsinterested in performing field air leakage tests on installed unitsshould reference Test Method E783. Test Method E783 will notprovide the user with a
8、means of determining air flow throughthe sides of tested specimens.1.4 Persons using this procedure should be knowledgeablein the areas of fluid mechanics, instrumentation practices, andshall have a general understanding of fenestration products andcomponents.1.5 The values stated in SI units are to
9、 be regarded asstandard. The values given in parentheses are mathematicalconversions to inch-pound units that are provided for informa-tion only and are not considered standard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsi
10、bility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatement see Section 7.2. Referenced Documents2.1 ASTM Standards:2E283 Test Method for Determining Rate of Air Leakag
11、eThrough Exterior Windows, Curtain Walls, and DoorsUnder Specified Pressure DifferencesAcross the SpecimenE631 Terminology of Building ConstructionsE783 Test Method for Field Measurement of Air LeakageThrough Installed Exterior Windows and Doors3. Terminology3.1 DefinitionsTerms used in this standar
12、d are defined inTerminology E631.3.2 Descriptions of Terms Specific to This Standard:3.2.1 air leakage rate through the face of the specimen(qA(f)or qlc(f), L/(sm2) (ft3/minft2), or L/(sm) (ft3/minft)the air leakage through the face of the specimen per unit ofspecimen area (A) or per unit length of
13、operable crackperimeter (lc).3.2.2 air leakage rate through the face and sides of thespecimen (qA(fs), L/(sm2) (ft3/minft2)the air leakagethrough the face and sides of the specimen per unit of specimenarea (A).1This test method is under the jurisdiction of ASTM Committee E06 onPerformance of Buildin
14、gs and is the direct responsibility of Subcommittee E06.51on Performance of Windows, Doors, Skylights and Curtain Walls.Current edition approved Nov. 1, 2011. Published December 2011. Originallyapproved in 2004. Last previous edition approved in 2004 as E2319 04. DOI:10.1520/E2319-04R11.2For referen
15、ced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West C
16、onshohocken, PA 19428-2959, United States.3.2.3 air leakage rate through the sides of the specimen(qA(s)or qlf(s), L/(sm2) (ft3/minft2), or L/(sm) (ft3/minft)the air leakage through the sides of the specimen per unit ofspecimen area (A) or per unit length of outside perimeter ofspecimen frame (lf).3
17、.2.4 air leakage through the face of the specimen (Qs(f),L/s (ft3/min)the volume of air flowing per unit of timethrough the face of the test specimen under a test pressuredifference and test temperature difference, converted to stan-dard conditions.3.2.5 air leakage through the face and sides of the
18、 specimen(Qs(fs), L/s (ft3/min)the volume of air flowing per unit oftime through the face and sides of the test specimen under a testpressure difference and test temperature difference, convertedto standard conditions.3.2.6 air leakage through the sides of the specimen (Qs(s),L/s (ft3/min)the volume
19、 of air flowing per unit of timethrough the sides of the test specimen under a test pressuredifference and test temperature difference, converted to stan-dard conditions.3.2.6.1 DiscussionAir leakage through the sides of theframe (Qs(s) is provided to inform specifiers of the potentialleakage throug
20、h the specimen at the window surrounds. Theactual amount of leakage through the sides of the framedepends on the positioning of the sealants, flashings and airbarriers relative to the frame.3.2.7 extraneous air leakage (Qe), L/s (ft3/min)the vol-ume of air flowing per unit of time through the test c
21、hamberand test apparatus, exclusive of the air flowing through the testspecimen, under a test pressure difference and test temperaturedifference, converted to standard conditions.3.2.7.1 DiscussionExtraneous leakage is the sum of allleakage other than that intended to be measured by the test.3.2.8 s
22、pecimenthe entire assembled unit submitted fortest as described in Section 8.3.2.9 specimen area (A), m2(ft2)the area determined bythe overall dimensions of the frame that fits into the roughopening.3.2.10 standard test conditionsin this test method, dry airat:Pressure101.3 kPa (29.92 in. Hg)Tempera
23、ture20.8C (69.4F)Air Density1.202 kg/m3(0.075 lb/ft3)3.2.11 test pressure differences, Pa (lbf/ft2)the specifieddifferential static air pressure across the specimen.3.2.12 total air flow through face (Qt(f), L/s (ft3/min)thevolume of air flowing per unit of time through the test chamberand test appa
24、ratus, inclusive of the air flowing through the faceof the test specimen but exclusive of the air flowing through thesides of the specimen, under a test pressure difference and testtemperature difference, converted to standard conditions.3.2.13 total air flow through face and sides (Qt(fs), L/s(ft3/
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME231920042011STANDARDTESTMETHODFORDETERMININGAIRFLOWTHROUGHTHEFACEANDSIDESOFEXTERIORWINDOWSCURTAINWALLSANDDOORSUNDERSPECIFIEDPRESSUREDIFFERENCESACROPDF

链接地址:http://www.mydoc123.com/p-530864.html