ASTM E2313-2015 Standard Test Method for Aldehydes in Mono- Di- and Triethylene Glycol (using Spectrophotometry)《单甘醇 双甘醇 三甘醇中醛类的标准试验方法 (分光光度法)》.pdf
《ASTM E2313-2015 Standard Test Method for Aldehydes in Mono- Di- and Triethylene Glycol (using Spectrophotometry)《单甘醇 双甘醇 三甘醇中醛类的标准试验方法 (分光光度法)》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2313-2015 Standard Test Method for Aldehydes in Mono- Di- and Triethylene Glycol (using Spectrophotometry)《单甘醇 双甘醇 三甘醇中醛类的标准试验方法 (分光光度法)》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2313 08E2313 15Standard Test Method forAldehydes in Mono-, Di-, and Triethylene Glycol(Spectrophotometric Method)(using Spectrophotometry)1This standard is issued under the fixed designation E2313; the number immediately following the designation indicates the year oforiginal adoption
2、or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method describes the spectrophotometric determination of total ald
3、ehyde carbonyl content in the range of 0.5 to50 mg/kg (as acetaldehyde) or 0.3 to 35 mg/kg (as formaldehyde) in mono-, di-, and triethylene glycol (MEG, DEG and TEG).Alkoxyalcohols (hemiacetals), if present, are co-determined, whereas dialkoxyalkanes (acetals), if present, are not. The resultsprovid
4、e a measure of the purity of the sample with respect to total aldehyde carbonyl content.1.2 Review the current Safety Data Sheets (SDS) for detailed information concerning toxicity, first aid procedures, and safetyprecautions for all materials used in this test method.1.3 The values stated in SI uni
5、ts are to be regarded as standard. No other units of measurement are included in this standard.1.3 Review the current material Safety Data Sheets (MSDS) for detailed information concerning toxicity, first aid proceduresand safety precautions.1.4 This standard does not purport to address all of the s
6、afety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent
7、WaterD2194 Test Method for Concentration of Formaldehyde SolutionsD6299 Practice for Applying Statistical Quality Assurance and Control Charting Techniques to Evaluate Analytical Measure-ment System PerformanceE180 Practice for Determining the Precision of ASTM Methods for Analysis and Testing of In
8、dustrial and Specialty Chemicals(Withdrawn 2009)3E275 Practice for Describing and Measuring Performance of Ultraviolet and Visible SpectrophotometersE288 Specification for Laboratory Glass Volumetric FlasksE300 Practice for Sampling Industrial ChemicalsE969 Specification for Glass Volumetric (Transf
9、er) Pipets2.2 Other Document:Manufacturers Instruction Manual of Spectrophotometer3. Summary of Test Method3.1 The total aldehyde carbonyl content of the sample is determined spectrophotometrically. The aldehydes present are reactedwith excess 3-methyl-2-benzothiazolinone hydrazone (MBTH) to form az
10、ines.An aqueous solution of iron (III) chloride is added,causing the oxidation of the excess MBTH to a reactive cation, which reacts with the previously formed azines producingbluish-green cations. Acetone or methanol is added to stop the oxidation reaction, to mask the excess MBTH and to obtain a c
11、learsolution. The absorbance of the test solution is measured spectrophotometrically at 635 nm. The amount of aldehyde present in1 This test method is under the jurisdiction of ASTM Committee E15 on Industrial and Specialty Chemicals and is the direct responsibility of Subcommittee E15.02 onProduct
12、Standards.Current edition approved April 1, 2008Nov. 1, 2015. Published May 2008January 2016. Originally approved in 2003. Last previous edition approved in 20042008 asE2313 04.E2313 08. DOI: 10.1520/E2313-08.10.1520/E2313-15.2 For referencedASTM standards, visit theASTM website, www.astm.org, or co
13、ntactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 The last approved version of this historical standard is referenced on www.astm.org.This document is not an ASTM standard and is inte
14、nded only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the curre
15、nt versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1the test solution is derived fro
16、m a previously prepared calibration graph. The aldehyde content of the sample, expressed as eitheracetaldehyde or formaldehyde, is calculated from the data obtained.4. Significance and Use4.1 Knowledge of the total aldehyde content of Monoethylenemonoethylene glycol is required to establish whether
17、the productmeets the requirements of its quality specifications.5. Apparatus5.1 Spectrophotometer, suitable for measurement at a wavelength of 635 nm, provided with cells with a pathlength of 10mm.10 mm.NOTE 1Further information on spectrophotometers can be obtained from Practice E275.5.2 Analytical
18、 Balance, readable to 0.1 mg, calibrated. Calibrate andRecalibrate or verify at regular intervals.5.3 Stopwatch, measuring accuracy 61 s or better. Calibrate or verify Verify at regular intervals.5.4 Apparatus, as described in Test Method D2194.5.4.1 Buret, calibrated, 100-mL, 100 mL, with a 5050- o
19、r 75-mL reservoir on top of a lower portion calibrated in 0.1-mLdivisions. A PTFE-fluorocarbon resin stopcock is suitable for this purpose. Recalibrate or verify at regular intervals.5.4.2 Erlenmeyer Flask, approximately 5-mL capacity.5.4.3 Vials, specimen, short, style, approximately 5-mL capacity.
20、5.4.4 Adjustable Volume Dispensing Pipette(s), capable of dispensing volumes in the range 1.00 to 5.00 mL, with suitabledisposable pipette tips. It is recommended to verify the capacity of the pipette(s) at regular intervals.5.5 Glassware:NOTE 2In cases where volumetric glassware is to be used, it s
21、hall conform to Grade (or Class) A specifications as described in, for example,Specification E288 for volumetric flasks, or Specification E969 for one-mark pipettes.5.5.1 Graduated Pipettes, capable of quantitatively transferring between 0.5 and 5 mL, or5.5.2 Volumetric Pipette,Pipettes, 0.5, 1.0, 2
22、.0, 3.0, 4.0, 5.0 mL.mL (if no adjustable volume dispensing pipettes are used).5.5.3 Volumetric Pipettes,Pipette, 25 mL.5.5.4 Volumetric Flasks, 100 mL, 1 L.5.5.5 Brown Bottle, 1 L, with screw cap, for storage.6. Reagents6.1 Purity of ReagentsUnless otherwise indicated, it is intended that all reage
23、nts shall conform to the specifications of thecommittee on Analytical Reagents of the American Chemical Society where such specifications are available.4 Other grades maybe used, provided it is first ascertained that the reagent is of sufficiently high purity to permit its use without lessening the
24、accuracyof the determination.6.1.1 Acetone (2-propanone), A.R. minimum purity 99.99 % (V/V). (WarningAcetone is highly flammable. Keep containerin a well-ventilated place. Keep away from sources of ignition. Do not breathe vapor. Take precautionary measures against staticdischarges.Warning) Acetone
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME23132015STANDARDTESTMETHODFORALDEHYDESINMONODIANDTRIETHYLENEGLYCOLUSINGSPECTROPHOTOMETRY 甘醇 中醛类

链接地址:http://www.mydoc123.com/p-530850.html