ASTM E2309-2005 Standard Practices for Verification of Displacement Measuring Systems and Devices Used in Material Testing Machines《用于材料试验机械的位移测量系统和装置验证的标准规程》.pdf
《ASTM E2309-2005 Standard Practices for Verification of Displacement Measuring Systems and Devices Used in Material Testing Machines《用于材料试验机械的位移测量系统和装置验证的标准规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2309-2005 Standard Practices for Verification of Displacement Measuring Systems and Devices Used in Material Testing Machines《用于材料试验机械的位移测量系统和装置验证的标准规程》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2309 05Standard Practices forVerification of Displacement Measuring Systems andDevices Used in Material Testing Machines1This standard is issued under the fixed designation E 2309; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These practices cover procedures and requirements forthe calibration and verification of dis
3、placement measuringsystems by means of standard calibration devices for static andquasi-static testing machines. This practice is not intended tobe complete purchase specifications for testing machines ordisplacement measuring systems. Displacement measuringsystems are not intended to be used for th
4、e determination ofstrain. See Practice E83.1.2 These procedures apply to the verification of the dis-placement measuring systems associated with the testingmachine, such as a scale, dial, marked or unmarked recorderchart, digital display, etc. In all cases the buyer/owner/usermust designate the disp
5、lacement-measuring system(s) to beverified.1.3 Since conversion factors are not required in this prac-tice, either SI units, or inch units, can be used as the standard.1.4 Displacement values indicated on displays/printouts oftesting machine data systemsbe they instantaneous, delayed,stored, or retr
6、ansmittedwhich are within the Classificationcriteria listed in Table 1, comply with Practices E 2309.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and hea
7、lth practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E83 Practice for Verification and Classification of Exten-someters3. Terminology3.1 Definitions:3.1.1 accuracy, ndegree of conformity of a measure to astandard.3.1.2 error
8、, nthe amount of deviation from a standard.3.1.2.1 DiscussionThe word “error” shall be used withnumerical values, for example, “At a displacement of +1.00 in.,the error of the displacement measuring system was +0.001in.”3.1.3 tolerance, nthe allowable deviation from a standard.3.2 Definitions of Ter
9、ms Specific to This Standard:3.2.1 calibration, nin the case of displacement measuringsystems used with testing machines, the process of comparingthe displacement indication of the machine or system under testto that of a standard, making adjustments as needed to meeterror requirements.3.2.2 capacit
10、y range, nin the case of testing machines, therange of displacement for which it is designed. Some testingmachines have more than one capacity range, that is, multipleranges.3.2.3 correction, nin the case of a testing machine, thedifference obtained by subtracting the measured displacementfrom the c
11、orrect value of the applied displacement.3.2.4 displacement, na movement or measurement oflength expressed in terms of millimeters, inches, etc.3.2.5 displacement measuring system, na device or set ofdevices comprised of a displacement transducer and associatedinstrumentation.3.2.6 lower limit of ve
12、rification range, nthe lowest valueof displacement at which a displacement measuring system canbe verified.3.2.7 percent error, nin the case of a displacement mea-suring system, the ratio, expressed as a percent, of the error tothe correct value of the applied displacement.3.2.7.1 DiscussionThe meas
13、ured displacement, as mea-sured by the testing machine, and the applied displacement, ascomputed from the readings of the verification device, shall berecorded at each verification displacement data point. Theerror, and the percent error, shall be calculated from this data asfollows:1These practices
14、 are under the jurisdiction of ASTM Committee E28 onMechanical Testing and is the direct responsibility of Subcommittee E28.01 onCalibration of Mechanical Testing Machines and Apparatus.Current edition approved Feb. 1, 2005. Published February 2005.2For referenced ASTM standards, visit the ASTM webs
15、ite, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United Stat
16、es.Error 5 A 2 BPercent Error 5 A 2 B!/B# 3 100where:A = displacement measured by the machine being verified,mm (in.), andB = correct value of the applied displacement, mm (in.), asdetermined by the calibration device.3.2.8 reference standard, na standard used to measuredisplacement applied by the t
17、esting machine and measured bythe displacement measuring system to be verified.3.2.9 resolution of the displacement indicator, nsmallestchange of displacement that can be estimated or ascertained onthe displacement measuring apparatus of the testing machine orsystem, at any applied displacement. App
18、endix X1 describes amethod for determining resolution.3.2.10 resolution of analog type displacement indicators(scales, dials, recorders, etc.), nthe resolution is the smallestchange in displacement indicated by a displacement of apointer, or pen line. The resolution is calculated by multiplyingthe d
19、isplacement corresponding to one graduation by the ratioof the width of the pointer or pen line to the center to centerdistance between two adjacent graduation marks.3.2.11 resolution of digital type displacement indicators(numeric, displays, printouts, etc.), nthe resolution is thesmallest change i
20、n displacement that can be displayed on thedisplacement indicator, at any applied displacement. AppendixX1 describes a method for determining resolution.3.2.11.1 DiscussionIf the displacement indication, foreither type of displacement indicator, fluctuates by more thantwice the resolution, as descri
21、bed in 3.2.9 or 3.2.10, theresolution, expressed as displacement, shall be equal to one-half the range of the fluctuation.3.2.12 relative repeatability, nthe closeness of the agree-ment between the results of successive measurements from thesame applied displacement, carried out under the same condi
22、-tions of measurement. It is expressed as percentage of the meanindicated output for the same applied displacement on twosuccessive calibrations for the given displacement.3.2.13 relative reversibility, nthe difference between themean measured displacement obtained for a given applieddisplacement ap
23、plied in an increasing mode and the meanindicated displacement obtained for the same given displace-ment applied in a decreasing mode.3.2.14 testing machine, na mechanical device for apply-ing force and displacement to a specimen.3.2.14.1 DiscussionThe instrumentation may be either anelectrical or a
24、 mechanical device, that is, a scale or pointersystem.3.2.15 verification, nin the case of displacement measur-ing systems used with testing machines, the process of com-paring the displacement indication of the machine or systemunder test to that of a standard and reporting results, withoutmaking a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME23092005STANDARDPRACTICESFORVERIFICATIONOFDISPLACEMENTMEASURINGSYSTEMSANDDEVICESUSEDINMATERIALTESTINGMACHINES

链接地址:http://www.mydoc123.com/p-530839.html