ASTM E2307-2015a Standard Test Method for Determining Fire Resistance of Perimeter Fire Barriers Using Intermediate-Scale Multi-story Test Apparatus《利用中型多层试验设备测定周边防火屏障防火性的标准试验方法》.pdf
《ASTM E2307-2015a Standard Test Method for Determining Fire Resistance of Perimeter Fire Barriers Using Intermediate-Scale Multi-story Test Apparatus《利用中型多层试验设备测定周边防火屏障防火性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2307-2015a Standard Test Method for Determining Fire Resistance of Perimeter Fire Barriers Using Intermediate-Scale Multi-story Test Apparatus《利用中型多层试验设备测定周边防火屏障防火性的标准试验方法》.pdf(23页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2307 15E2307 15a An American National StandardStandard Test Method forDetermining Fire Resistance of Perimeter Fire BarriersUsing Intermediate-Scale, Multi-story Test Apparatus1This standard is issued under the fixed designation E2307; the number immediately following the designation i
2、ndicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONA perimeter fire barrier is the perimet
3、er joint protection that provides fire resistance to preventpassage of fire from floor to floor within the building at the opening between the exterior wallassembly and the floor assembly. A perimeter fire barrier is a unique building construction detail notaddressed by other fire test methods.Among
4、 its other functions, a perimeter fire barrier impedes the vertical spread of fire from the floorof origin to the floor(s) above, at the buildings exterior perimeter and accommodates variousmovements such as those induced by thermal differentials, seismicity, and wind loads.This test method describe
5、s criteria and test methods used to determine the fire resistance ofperimeter fire barriers when subjected to standard fire exposure conditions using the intermediate-scale, multistory test apparatus (ISMA). The use of the multi-story test apparatus and this test methodare intended to simulate a pos
6、sible fire exposure on a perimeter fire barrier.1. Scope1.1 This test method measures the performance of the perimeter fire barrier and its ability to maintain a seal to prevent firespread during the deflection and deformation of the exterior wall assembly and floor assembly during the fire test, wh
7、ile resistingfire exposure from an interior compartment fire as well as from the flame plume emitted from the window burner below. The endpoint of the fire-resistance test is the period of time elapsing before the first condition of compliance is reached as the perimeterfire barrier is subjected to
8、a time-temperature fire exposure.1.2 The fire exposure conditions used are those specified by this test method for the first 30 min of exposure and then conformto the Test Methods E119 time-temperature curve for the remainder of the test in the test room.1.3 This test method specifies the heating co
9、nditions, methods of test, and criteria for evaluation of the ability of a perimeterfire barrier to maintain the fire resistance where a floor and exterior wall assembly are juxtaposed to a perimeter joint.1.4 Test results establish the performance of perimeter fire barriers during the fire-exposure
10、 period and shall not be construedas having determined the suitability of perimeter fire barriers for use after that exposure.1.5 This test method does not provide quantitative information about the perimeter fire barrier relative to the rate of leakage ofsmoke or gases or both. While it requires th
11、at such phenomena be noted and reported when describing the general behavior ofperimeter fire barrier during the fire-resistance test, such phenomena are not part of the conditions of compliance.1.6 Potentially important factors and fire characteristics not addressed by this test method include, but
12、 are not limited to:1.6.1 The performance of the perimeter fire barrier constructed with components other than those tested, and1.6.2 The cyclic movement capabilities of perimeter fire barriers other than the cycling conditions tested.1.7 This test method is used to measure and describe the response
13、 of materials, products or assemblies to heat and flame undercontrolled conditions but does not by itself incorporate all factors required for the fire-hazard or fire-risk assessment of thematerials, products, or assemblies under actual fire conditions.1.8 The values stated in inch-pound units are t
14、o be regarded as standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information only and are not considered standard.1 This test method is under the jurisdiction of ASTM Committee E05 on Fire Standards and is the direct responsibility of Subcommit
15、tee E05.11 on Fire Resistance.Current edition approved Jan. 15, 2015April 1, 2015. Published February 2015May 2015. Originally approved in 2004. Last previous edition approved in 20102015 asE2307-10.E2307-15. DOI: 10.1520/E2307-15.10.1520/E2307-15A.This document is not an ASTM standard and is intend
16、ed only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current
17、 versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States11.9 The text of this test method references notes and footnotes which provide explanatory material.
18、 These notes and footnotes(excluding those in tables and figures) shall not be considered as requirements of the standard.1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appr
19、opriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E84 Test Method for Surface Burning Characteristics of Building MaterialsE108 Test Methods for Fire Tests of Roof CoveringsE119 Test Methods for Fire T
20、ests of Building Construction and MaterialsE176 Terminology of Fire StandardsE511 Test Method for Measuring Heat Flux Using a Copper-Constantan Circular Foil, Heat-Flux TransducerE631 Terminology of Building ConstructionsE1529 Test Methods for Determining Effects of Large Hydrocarbon Pool Fires on S
21、tructural Members and AssembliesE1966 Test Method for Fire-Resistive Joint Systems2.2 Other Documents:Uniform Building Code Standard No. 26-9 Method of Test for the Evaluation of Flammability Characteristics of Exterior,Non-Loadbearing Wall Assemblies Containing Combustible Components Using the Inte
22、rmediate-Scale Multistory TestApparatus3NFPA 285 Standard Method of Test for the Evaluation of Flammability Characteristics of Exterior Non-Load-Bearing WallAssemblies Containing Combustible Components Using the Intermediate-Scale, Multistory Test Apparatus4The 14th Edition of the Gypsum Association
23、s Fire Resistance Design Manual (GA 600 94)53. Terminology3.1 Terms defined inTerminology E176 and E631 shall prevail for fire standard and building terms not defined in this document.3.2 Definitions:3.2.1 blockout, na recess formed in the floor assembly to accommodate the installation of the perime
24、ter joint protection, flushwith the wearing surface of the floor assembly.3.2.2 curtain wall assembly, neither a rated or non-rated, nonbearing exterior wall assembly secured to and supported by thestructural members of the building.3.2.3 exterior wall assembly, na curtain wall or a loadbearing exte
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME23072015ASTANDARDTESTMETHODFORDETERMININGFIRERESISTANCEOFPERIMETERFIREBARRIERSUSINGINTERMEDIATESCALEMULTISTORYTESTAPPARATUS

链接地址:http://www.mydoc123.com/p-530834.html